c11010.0
AIR CONDITIONING
Fault finding - Interpretation of XR25 bargraphs62
KANGOO
ALL TYPES
Enter G0** on the XR25.
Check that the system operates correctly.AFTER
REPAIR
Right-hand bargraph 6 illuminated
FAN ASSEMBLY (1) CONTROL
XR25 assistance:C.O.open circuit
C.C.1short circuit to 12 volts
6
NOTES
Fiche n° 61
Check the condition of the earth of fan assembly (1) (the relay is controlled by 0 volt).
Repair the fan assembly earth if necessary.
Check that the air conditioning has been selected.
Enter G0** on the XR25.
If right-hand bargraph 6 remains illuminated, you can begin the fault finding
procedure.
Connect the XR25 and enter #16. Check that the coolant pressure is approximately 10 bars.
If it is not, top up the coolant (operation of the cooling fan assembly is dependent on the coolant
pressure).
Check that the air conditioning is operating.
Fan assembly (1) is controlled from the time the air conditioning is switched on.
Check the operating status of the relay by entering G22* on the XR25.
The fan assembly should be heard to knock.
Is the fan assembly heard to knock?
YES
Change the relay of fan assembly (1).NO
Check the continuity and insulation from 12 volts of the electrical wiring
between track M2 and track 22 of the air conditioning control unit 30-way
connector.
Repair the faulty electrical wiring.
62-15