Fault finding – Introduction62B
V3 MR-372-J84-62B000$010.mif
Vdiag No.: 44
162BCLIMATE CONTROL
Fault finding – Introduction
1. SCOPE OF THIS DOCUMENT
This document presents the fault finding procedure applicable to all computers with the following specifications:
2. PREREQUISITES FOR FAULT FINDING
Documentation type:
Fault finding procedures (this manual):
–Assisted fault finding (integrated into the diagnostic tool), Dialogys.
Wiring Diagrams:
–Visu-Schéma (CD-ROM), paper version.
Type of diagnostic tools:
–CLIP
Type of special tooling required:
3. RECAP
Procedure
To run fault finding on the vehicle's computers, switch on the ignition in fault finding mode (forced + after ignition
feed).
Proceed as follows:
–Renault card in the card reader (keyless vehicle scenario 1, standard, not hands-free and scenario 2, top of
the range, hands-free),
–press and hold the Start button (longer than 5 seconds) with start-up conditions not fulfilled,
–then connect the diagnostic tool and perform the required operations.
To cut off + after ignition, proceed as follows:
–disconnect the diagnostic tool,
–press the Start button twice briefly (less than 3 seconds),
–check that the + after ignition feed has been cut off by checking that the computer warning lights on the
instrument panel have gone out. Vehicle: Scénic II
Function concerned: Climate controlComputer name: Careg
Program No.: 0003
Vdiag No.: 44
SPECIAL TOOLING REQUIRED
Multimeter
Elé. 1681 Universal bornier
Note:
The left-hand and right-hand xenon bulb computers are powered when the dipped headlights are lit. Fault finding
procedures can only be carried out on them after the ignition has been switched on in fault finding mode (+ after
ignition imposed) and the dipped headlights are on.
ACREG X84 1.1
Edition 2
MR-372-J84-62B000$010.mif
Page 40 of 60
62B - 40
CLIMATE CONTROL
Fault finding – Conformity check62B
V3 MR-372-J84-62B000$090.mif
Vdiag No.: 44
MAIN SCREEN
NOTESOnly carry out this conformity check after a full check with the diagnostic tool (fault
reading and configuration checks).
Test conditions: engine off, ignition on (forced 12 V After ignition).
Air conditioning off (air conditioning compressor not triggered).
Special note:
The various conformity checks for the air conditioning function are explained in the
Introduction section.
Note:
This page lists the statuses and parameters provided by the climate control computer
but which are not associated with the four sub-functions given in the conformity check
(PASSENGER COMPARTMENT VENTILATION, COLD LOOP, USER SELECTION
and HEATING sub-functions).
Order FunctionParameter or Status
checked or Action Display and Notes Fault finding
1Electrical
suppliesPR092:Battery voltage10.5 < X < 14.4 VIn the event of a fault, see
the interpretation of this
parameter
ET007:+ after ignition
computer feedABSENT: Ignition off.
PRESENT: Ignition on.In the event of a fault, refer
to the interpretation of
this status.
ET002:+ 12 V side
lightsABSENT: Side lights
off.
PRESENT: Side lights
on.In the event of a fault,
consult the interpretation
of this status (see 87B,
Passenger compartment
connection unit).
PR122:Night-time
lighting level6% = minimum lighting
level.
99% = maximum
lighting level.
(side lights off: 102%)In the event of a fault, refer
to the interpretation of
parameter PR111 Lighting
dimmer voltage (see 83A,
Instrument panel).
ACREG X84 1.1
Edition 2
Page 54 of 60
62B-54
CLIMATE CONTROL
Fault finding – Fault Finding Chart62B
V3 MR-372-J84-62B000$110.mif
Vdiag No.: 44
ALP 13 No control panel lighting
NOTESOnly refer to this customer complaint after a full check of the multiplex network
and the air conditioning with the fault finding tool.
Special notes:
With the ignition on, the control panel screen is permanently on but the panel buttons
only light up when the sidelights are switched on.
Note:
If the external temperature sensor is faulty, the climate control computer is
switched on 5 seconds after the ignition is switched on (this allows a fault to be
identified as fault finding cannot be performed on the external temperature sensor
by the UCH).
Is the fault common to other components (instrument panel,
multifunction display, electric window buttons, etc.)?
YES
Switch on the ignition and switch on the side lights to check
there is a 12 V supply on track 6 of the brown 12-track
connector (PPH2) of the Protection and Switching Unit.
Is there a 12 V supply?
YES
Check the connection and the condition of the connectors at the air conditioning control panel
output.
Repair if necessary.
Check the insulation, continuity and absence of interference resistance on the following
connection:
Air conditioning computer 12-track connector
track 9
Repair if necessary.Protection and Switching Unit brown 12-track
(PPH2) connector
track 6
NO
NOPerform fault finding on the
protection and switching unit.
AFTER REPAIRPerform a complete check using the diagnostic tool.
ACREG X84 1.1
Edition 2
Page 55 of 60
62B-55
CLIMATE CONTROL
Fault finding – Fault Finding Chart62B
V3 MR-372-J84-62B000$110.mif
Vdiag No.: 44
ALP 13
CONTINUED
Using the diagnostic tool and the conformity
check in this document, check that the lighting
rheostat is working correctly using parameter
PR122 Night-time lighting level.
Does the parameter vary?
YES
Is the fault still present?
YES
Contact your TECHLINE.
NO
NO Use the diagnostic tool to check the
instrument panel (which is providing the 0 V
rheostat controlled information).
If fault DF037 "Instrument panel lighting
rheostat" is present: apply the associated fault
finding procedure (see corresponding
section).
If no faults are present or stored: run fault
finding on the multiplex network (the 0 V
rheostat controlled signal is reaching the air
conditioning control panel on the multiplex
network).
End of fault finding procedure.
AFTER REPAIRPerform a complete check using the diagnostic tool.