reset RENAULT SCENIC 2009 J84 / 2.G Air Conditioning Climate Control Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: SCENIC, Model: RENAULT SCENIC 2009 J84 / 2.GPages: 60
Page 35 of 60
62B - 35
CLIMATE CONTROL
Fault finding – Conformity check62B
V3 MR-372-J84-62B000$090.mif
Vdiag No.: 44
CLIMATE CONTROL
Fault finding – Conformity check
PASSENGER COMPARTMENT VENTILATION SUB-FUNCTION
NOTESOnly carry out this conformity check after a full check with the diagnostic tool (fault
reading and configuration checks).
Test conditions: engine off, ignition on (forced 12 V After ignition).
Air conditioning off
(air conditioning compressor not triggered).
Special note:
The various conformity checks
for the air conditioning function are explained in the
Introduction section.
Note:
–Read the parameters when the vehicle is cold (in the morning) to check the
conformity of the temperature parameters (without thermometer). The two
temperatures should be practically the same (as should the coolant temperature
given by the injection system).
–The invalid values given in this check correspond to the value sent by the diagnostic
tool (substitute value) when the sensor in question is faulty. A sensor fault can be
detected when these invalid values are displayed (this is an important point for
sensors on which fault finding cannot be performed, e.g. exterior temperature
sensor).
Order FunctionParameter or Status
checked or Action Display and Notes Fault finding
1TemperaturesPR001:Interior
temperatureX = interior
temperature ± 5 ˚C
(invalid value: 87.5 ˚C)If there is a fault, refer to the
fault finding procedure
for this parameter.
PR002:Exterior
temperatureX = exterior
temperature ± 5 ˚C
(invalid value: 215 ˚C)
Note: This status is
reset by the climate
control computer but
its source is the UCH.In the event of a fault, refer
to the interpretation of this
parameter (see
Section 87B).
2Solar radiationPR006:Solar radiationfrom 0 W
(no solar radiation) to
400 W
(maximum solar
radiation)
(invalid value:
765 W)In the event of a fault, see
the interpretation of this
parameter.
ACREG X84 1.1
Edition 2