62C - 4
MANUAL AIR CONDITIONING
Fault finding – Introduction62C
V2 MR-372-J84-62C000$010.mif
4. FAULT FINDING PROCEDURE
Check the battery charge and
condition of the fuses
Print the system fault finding log
(available in CLIP or in the
Workshop Repair Manual or
Technical Note)
Connect CLIP
Dialogue with
computer?
Read faults
Faults present
Deal with faults found
Deal with stored faults
The symptom
persists
Refer to fault finding chart 1
(Section 62A)
Conformity check
The symptom
persists
Use fault finding charts
The symptom
persists
Contact Techline with the
completed fault finding log
no
yes
no
yes
no
yesno
no
Fault
resolvedFault
resolved
Fault
resolved
Page 5 of 23
MANUAL AIR CONDITIONING
Fault finding – Introduction62C
62C - 5V2 MR-372-J84-62C000$010.mif
You will always be asked for this log:
–When requesting technical assistance from the Techline.
–For certification requests when replacing parts that must be certified.
–Which must be attached to monitored parts for which reimbursement is requested. It is therefore used to decide
whether a reimbursement will be made under warranty and leads to improved analysis of the removed parts.
6. SAFETY INSTRUCTIONS
All work on components requires the observation of safety rules to prevent physical damage or human injury:
–Make sure the battery is properly charged to avoid damaging the computers with a low charge.
–Do not smoke,
–Use the proper tools.WARNING:5. FAULT FINDING LOG
WARNING: A full fault finding procedure must be carried out for all faults on a complex system
using suitable tools. The FAULT FINDING LOG, which should be completed during the fault
finding procedure, ensures a record is kept of the procedure carried out. It is an essential item
when discussing the fault with the constructor.
IT IS THEREFORE MANDATORY TO FILL OUT A FAULT FINDING LOG EACH TIME
FAULT FINDING IS