oil temperature RENAULT SCENIC 2009 J84 / 2.G Automatic Transmission AJ0 BVA User Guide
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: SCENIC, Model: RENAULT SCENIC 2009 J84 / 2.GPages: 162
Page 30 of 162
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 30V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
DF023
CONTINUED 2
Stage 4:
Measure the resistance of the oil temperature sensor (on connector R22) between the following connections:
●Connection code 5BZ,
●Connection code 5BY.
The resistance should be between:
–4.208 ± 0.42 kΩΩ Ω Ω
at 20 ˚C,
–1.947 ± 0.19 kΩΩ Ω Ω
at 40 ˚C,
–0.988 ± 0.09 kΩΩ Ω Ω
at 60 ˚C,
Is the resistance correct?
If YES, and if the fault is still present, contact the Techline.
If NO, move on to step 5.
Stage 5:
Drain the automatic transmission (see, MR 370, Mechanical, 23A Automatic transmission, Oil change)
and remove the transmission housing (see, MR 370, Mechanical, 23A Automatic transmission, Hydraulic
distributor).
Measure the resistance of the transmission temperature sensor (on the connector of the internal wiring
harness on the transmission) between the following connections:
●Connection code 5BZ,
●Connection code 5BY.
The resistance should be between:
–4.208 ± 0.42 kΩΩ Ω Ω
at 20 ˚C,
–1.947 ± 0.19 kΩΩ Ω Ω
at 40 ˚C,
–0.988 ± 0.09 kΩΩ Ω Ω
at 60 ˚C,
Is the resistance correct?
If YES, move on to step 6.
If NO, replace the internal wiring harness on the automatic transmission.
Stage 6:
Measure the continuity and insulation of the following connections:
●Connection code 5BZ,
●Connection code 5BY.
Between components R22 and the internal connector in the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the wiring harness between connector R22 and the internal connector in the transmission.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
Page 51 of 162
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 51V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
*EVS2 = sequence solenoid valve 2DF097
PRESENT
OR
STORED
CONVERTER lock-up
1.DEF: CONVERTER LOCK-UP CONTROL
NOTESOrder of priority in the event of more than one fault:
If there is a combination of the following faults:
–DF097 "Converter lock-up",
–DF086 "Sequence solenoid valve circuit "EVS2*""
–DF306 "Lock-up/brake 1 solenoid valve circuit",
deal first with faults DF086 "Sequence solenoid valve "EVS2*"" and DF306 "Lock-
up/brake 1 solenoid valve circuit".
Conditions for applying fault finding procedures to stored faults:
The fault is declared present after:
If in lock-up:
Lever in Manual position,
and difference in *slippage speed ≥ 40 + Vehicle speed / 2 for a certain time,
and EVS2* solenoid valve control status > 95 %.
In the event of slippage:
Lever in Manual position,
and difference in slippage speed ≥ 40 + slippage speed setpoint for a certain time,
and EVS2* solenoid valve control status > 95 %.
*slippage = engine speed - turbine speed
Effect on system:
Increase in oil temperature.
–In the event of engagement fault, lock-up inhibited.
–In the event of slippage fault, lock-up slippage inhibited.
Customer complaint:
Warning light on.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF097/AJ0_V05_DF097
Page 134 of 162
AUTOMATIC TRANSMISSION
23A
23A - 134V3 MR-372-J84-23A000$720.mif
AJ0 BVA
Vdiag No.: 04, 05AUTOMATIC TRANSMISSION
Fault finding - Parameter summary table
Tool parameter Diagnostic tool title
PR004Transmission oil temperature
PR006Engine speed
PR007Turbine speed
PR008Computer voltage supply
PR022Accelerator pedal position
PR067Calculated accelerator pedal position
PR105Vehicle speed
PR106Effective engine torque
PR123Calculated engine torque
PR153Slow torque setpoint
PR154Rapid torque setpoint
MR-372-J84-23A000$720.mif
Page 135 of 162
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters
23A
23A - 135V3 MR-372-J84-23A000$765.mif
AJ0 BVA
Vdiag No.: 04, 05AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters
PR004
TRANSMISSION OIL TEMPERATURE
PARAMETER
DEFINITIONThis parameter shows the gearbox oil temperature in ˚C.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
No faults should be present or stored.
Conformity check with engine running, engine coolant temperature > 80 ˚C
With the engine running at idle speed, the gearbox oil temperature varies in accordance with the engine coolant
temperature.
- 40 ˚C > PR004 > 150 ˚C
In the event of a fault, consult the interpretation of fault DF023 Gearbox oil temperature sensor.
Sensor electrical conformity
Disconnect the connector of component 119, measure the resistance of the oil temperature sensor
(on the connector of component 119) between the following connections:
●Connection code 5BZ,
●Connection code 5BY.
The resistance should be between:
- 4.208 ± 0.42 kΩΩ Ω Ω
at 20 ˚C,
- 1.947 ± 0.19 kΩΩ Ω Ω
at 40 ˚C,
- 0.988 ± 0.09 kΩΩ Ω Ω
at 60 ˚C.
In the event of a fault, consult the interpretation of fault DF023 Gearbox oil temperature sensor.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
AJ0_V04_PR004/AJ0_V05_PR004
MR-372-J84-23A000$765.mif
Page 137 of 162
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters
23A
23A - 137V3 MR-372-J84-23A000$765.mif
AJ0 BVA
Vdiag No.: 04, 05
PR007
TURBINE SPEED
Note:
Parameter PR007 "Turbine speed" applies to the following sub-functions:
"Gear changes".
"Torque activation".
PARAMETER
DEFINITIONThis parameter shows the gearbox turbine speed in rpm.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
No faults should be present or stored.
Conformity check with engine stopped and ignition on
PR007 = 0 rpm
In the event of a fault, consult the interpretation of fault DF038 Turbine speed sensor circuit.
Conformity check with engine running, engine coolant temperature > 80 ˚C
PR007 "Turbine
speed"PR006 "Engine
speed"PR004 "Gearbox
oil temperature"ET013 "Gear
engaged"ET012 "Gear lever
position"
0 rpm≈ 800 rpm 25 ˚C 1 D
≈ 660 rpm≈ 800 rpm 25 ˚CDISENGAGE
(clutch
disengagement)D
In the event of a fault, consult the interpretation of fault DF038 Turbine speed sensor circuit.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
AJ0_V04_PR007/AJ0_V05_PR007