torque RENAULT SCENIC 2009 J84 / 2.G Automatic Transmission AJ0 BVA Owner's Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: SCENIC, Model: RENAULT SCENIC 2009 J84 / 2.GPages: 162
Page 139 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters
23A
23A - 139V3 MR-372-J84-23A000$765.mif
AJ0 BVA
Vdiag No.: 04, 05
PR022
ACCELERATOR PEDAL POSITION
Note:
Parameter PR022 "Accelerator pedal position" applies to the following sub-functions:
"Gear changes".
"Torque activation".
"Driver parameters".
PARAMETER
DEFINITIONThis parameter indicates the accelerator pedal position as a %.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
No faults should be present or stored.
Conformity check with engine stopped and ignition on
Full load: PR022 "Accelerator pedal position" ≈≈ ≈ ≈
114 % and PR067 "Calculated accelerator pedal position"
= 100 %.
In the event of a fault (see 13B EDC16 CP33 M9R 721, Interpretation of faults, DF196 "Pedal sensor gang 1
circuit" or DF198 "Pedal sensor gang 2 circuit").
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
AJ0_V04_PR022/AJ0_V05_PR022
Page 140 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters
23A
23A - 140V3 MR-372-J84-23A000$765.mif
AJ0 BVA
Vdiag No.: 04, 05
PR067
CALCULATED ACCELERATOR PEDAL POSITION
Note:
Parameter PR067 "Accelerator pedal position" applies to the following sub-functions:
"Gear changes".
"Torque activation".
PARAMETER
DEFINITIONThis signal is supplied by the injection computer when the cruise control/speed limiter
is operating and when there is no longer a signal from the accelerator pedal. This
parameter indicates the accelerator pedal position as a %.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
No faults should be present or stored.
Conformity check with engine stopped and ignition on, engine running, engine coolant
temperature > 80 ˚C
Full load: PR022 "Accelerator pedal position" ≈≈ ≈ ≈
114 % and PR067 "Calculated accelerator pedal position"
= 100 %.
In the event of a fault (see 13B EDC16 CP33 M9R 721, Interpretation of faults, DF196 "Pedal sensor gang 1
circuit" or DF198 "Pedal sensor gang 2 circuit").
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
AJ0_V04_PR067/AJ0_V05_PR067
Page 142 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters
23A
23A - 142V3 MR-372-J84-23A000$765.mif
AJ0 BVA
Vdiag No.: 04, 05
PR106
EFFECTIVE ENGINE TORQUE
Note:
Parameter PR106 "Effective engine torque" applies to the following sub-functions:
"Gear changes".
"Torque activation".
PARAMETER
DEFINITIONThis parameter indicates the effective engine torque in Nm. This signal is supplied to
the gearbox computer by the injection computer.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
No faults should be present or stored.
Conformity check with engine ignition on and engine running at idle speed.
PR006 "Engine
speed"PR007 "Turbine
speed"PR106 "Effective
engine torque"PR153 "Slow
torque"PR154 "Fast
torque"
0 rpm 0 rpm 140 Nm 360 Nm - 32 Nm
≈ 802 rpm≈ 704 rpm≈ 34 Nm≈ 360 Nm≈ - 30 Nm
In the event of a fault, carry out a multiplex network test (see 88B, Multiplexing).
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
AJ0_V04_PR106/AJ0_V05_PR106
Page 143 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters
23A
23A - 143V3 MR-372-J84-23A000$765.mif
AJ0 BVA
Vdiag No.: 04, 05
PR153
SLOW TORQUE SETPOINT
Note:
Parameter PR153 "Slow torque setpoint" applies to the following sub-function:
"Slow torque activation".
PARAMETER
DEFINITIONThis parameter indicates the slow torque setpoint in Nm.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
No faults should be present or stored.
Conformity check with engine ignition on and engine running at idle speed.
PR006 "Engine
speed"PR007 "Turbine
speed"PR106 "Effective
engine torque"PR153 "Slow
torque"PR154 "Fast
torque"
0 rpm 0 rpm 140 Nm 360 Nm - 32 Nm
≈ 802 rpm≈ 704 rpm≈ 34 Nm≈ 360 Nm≈ - 30 Nm
In the event of a fault, carry out a multiplex network test (see 88B, Multiplexing).
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
AJ0_V04_PR153/AJ0_V05_PR153
Page 144 of 162

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters
23A
23A - 144V3 MR-372-J84-23A000$765.mif
AJ0 BVA
Vdiag No.: 04, 05
PR154
FAST TORQUE SETPOINT
Note:
Parameter PR154 "Fast torque setpoint" applies to the following sub-function:
"Torque activation".
PARAMETER
DEFINITIONThis parameter indicates the fast torque setpoint in Nm.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
No faults should be present or stored.
Conformity check with engine ignition on and engine running at idle speed.
PR006 "Engine
speed"PR007 "Turbine
speed"PR106 "Effective
engine torque"PR153 "Slow
torque"PR154 "Fast
torque"
0 rpm 0 rpm 140 Nm 360 Nm - 32 Nm
≈ 802 rpm≈ 704 rpm≈ 34 Nm≈ 360 Nm≈ - 30 Nm
In the event of a fault, carry out a multiplex network test (see 88B, Multiplexing).
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
AJ0_V04_PR154/AJ0_V05_PR154