warning RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals EDC16 Owner's Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2011, Model line: SCENIC, Model: RENAULT SCENIC 2011 J95 / 3.GPages: 365, PDF Size: 2.11 MB
Page 50 of 365

13B-50
MR-372-J84-13B200$252.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF012
PRESENT
OR
STOREDSENSOR SUPPLY VOLTAGE NO. 2
1.DEF: Sensor reference voltage too low
2DEF: Sensor reference voltage too high
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after carrying out a road test or after several attempts at
starting the engine.
Special notes:
If the fault is present:
– the EGR functions and passenger compartment heating resistance functions are
inhibited,
– the cruise control/speed limiter function is inhibited,
– the engine speed is limited,
– the level 1 warning light is lit,
– the OBD warning light illuminates after three consecutive driving cycles (starting
+ 5 seconds + switch off the ignition and wait 1 minute).
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This check enables the condition and the conformity of the engine wiring harness to be checked.
Check the condition of the connectors of the EGR valve position sensor, component code 1460, of the
accelerator pedal potentiometer gang 2 sensor, component code 921 and of the refrigerant pressure
sensor, component code 1202.
Check the condition of the injection computer connector, component code 120.
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
The following sensors are connected to supply no. 2:
– EGR valve position sensor.
– Accelerator pedal potentiometer track 2 sensor.
– Refrigerant pressure sensor.
To locate a faulty sensor and/or connection, disconnect one of these sensors then check whether the fault
becomes stored.
If the fault is still present, repeat the operation with the other sensors.
(Wait a few seconds after each disconnection so that the computer can carry out the check).
If the fault is stored after a disconnection, replace the faulty sensor or repair its connection.
Clear the faults created by the multiple disconnections.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF012/EDC16_V58_DF012/EDC16_V5C_DF012/EDC16_V18_DF012/EDC16_V1C_DF012/EDC16_V20_DF012
Page 52 of 365

13B-52
MR-372-J84-13B200$252.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF013
PRESENT
OR
STOREDSENSOR SUPPLY VOLTAGE NO. 3
1.DEF: Sensor reference voltage too low
2DEF: Sensor reference voltage too high
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after carrying out a road test or after several attempts at
starting the engine.
Special notes:
If the fault is present:
– the EGR function is inhibited,
– the engine stops,
– the level 2 warning light is lit,
– the OBD warning light illuminates after three consecutive driving cycles (start the
engine + 5 seconds + switch off the ignition and wait 1 minute).
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This check enables the condition and the conformity of the engine wiring harness to be checked.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF013/EDC16_V58_DF013/EDC16_V5C_DF013/EDC16_V18_DF013/EDC16_V1C_DF013/EDC16_V20_DF013
Page 55 of 365

13B-55
MR-372-J84-13B200$252.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF015
PRESENT
OR
STOREDMAIN RELAY CONTROL CIRCUIT
1.DEF : Relay cut out too soon
2.DEF : Relay cut out too late
NOTESConditions for applying the fault finding procedure to stored faults:
Only deal with this fault if it is stored.
Special notes:
The supply relay of the injection control unit (50A) is located on a relay plate in the
engine connection unit under the Protection and Switching Unit.
If the fault is present, the level 1 warning light is lit.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
Check the Protection and Switching Unit connections (Vdiag 50, 58, 5C only).
Check the injection computer connections.
Repair if necessary.
Check the condition of the battery terminals making sure they are correctly tightened.
Check the condition of the injection supply relay and its mounting.
Check the 5D (5A) + after ignition supply located on the UPC (Protection and Switching Unit) (Vdiag 50, 58, 5C
only).
Repair if necessary.
Check the continuity and absence of interference resistance of connection 3AA between components 120 and
983.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
IMPORTANT!WA R N I N G
If the Protection and Switching Unit (Vdiag 50, 58, 5C only) no longer detects the injection
computer signals, GMV 1 will be actuated until the battery is completely discharged.
In the event that engine cooling fan 1 is not working, GMV 2 will be supplied.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF015/EDC16_V58_DF015/EDC16_V5C_DF015/EDC16_V18_DF015/EDC16_V1C_DF015/EDC16_V20_DF015
Page 56 of 365

13B-56
MR-372-J84-13B200$252.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF017
PRESENT
OR
STOREDPRE-POSTHEATING UNIT CONTROL CIRCUIT
CC.1: Short circuit to + 12 V
CC.0:Open circuit or short circuit to earth
CO: Open circuit
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after several attempts to start the engine or after running
actuator command AC001 Preheating unit.
Special notes:
If the fault is present, it is difficult or even impossible to start the vehicle when cold.
If the fault is present, the level 1 warning light is lit.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
CC.1
NOTESNone
Check the pre-postheating unit connections and the heating plug supply cables.
Check the injection computer connections.
Repair if necessary.
Check the condition of supply fuse F2 (70A) on the power supply fuse board.
Check the continuity and insulation from + 12 V of the following connections:
– connection code 3FF,
– connection code3FY,
Between components 120 and 257.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the pre-postheating unit.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF017/EDC16_V58_DF017/EDC16_V5C_DF017/EDC16_V18_DF017/EDC16_V1C_DF017/EDC16_V20_DF017
Page 58 of 365

13B-58
MR-372-J84-13B200$252.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF025
PRESENT
OR
STOREDPRE-POSTHEATING UNIT DIAGNOSTIC LINE
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after several attempts to start the engine or after running
actuator command AC001 Preheating unit.
Special notes:
It is difficult or even impossible to start the engine when cold.
If the fault is present, the level 1 warning light is lit.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
Check the pre-postheating unit connections.
Check the connections on all of the heater plugs.
Repair if necessary.
Check fuse F2 for Mégane II and Scénic II and FM12 for Laguna II (70A) located on the power supply fuse
board.
Check the resistance of the heater plugs:
Replace any plugs whose resistance is not less than 2 Ω at + 20°C.
Check the continuity and absence of interference resistance of the following connections:
– connection code 37AB between components 257 and 682.
– connection code 37AC between components 257 and 683.
– connection code 37Z between components 257 and 680.
– connection code 37AA between components 257 and 681.
Check for + 12 V on connection BP35 of the preheating unit (via fuse F2 for Mégane II and Scénic II and FM12
for Laguna II (70A).
If the fault is still present.
Check the injection computer connections.
Check the continuity and absence of interference resistance of the following connections:
– connection code3FY,
– connection code 3FF.
Between components 120 and 257.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the pre-postheating unit.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF025/EDC16_V58_DF025/EDC16_V5C_DF025/EDC16_V18_DF025/EDC16_V1C_DF025/EDC16_V20_DF025
Page 62 of 365

13B-62
MR-372-J84-13B200$288.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF037
PRESENT
OR
STOREDENGINE IMMOBILISER
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after an attempt to start engine.
Special notes:
It is impossible to start the vehicle.
If the fault is present, the level 2 warning light is lit.
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
Check the UCH connections.
Check the injection computer connections.
Repair if necessary.
Perform a multiplex network test and run complete fault finding on the UCH (see 87B, Passenger compartment
connection unit) if the fault is declared present.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF037/EDC16_V58_DF037/EDC16_V5C_DF037/EDC16_V18_DF037/EDC16_V1C_DF037/EDC16_V20_DF037EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
MR-372-J84-13B200$288.mif
Page 63 of 365

13B-63
MR-372-J84-13B200$288.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF038
PRESENT
OR
STORED
COMPUTER1.DEF: Permanent high signal
2.DEF: Permanent low signal
3.DEF: Configuration absent or incorrect
4.DEF: Analogue/digital converter fault
5.DEF: Communication disrupted
6.DEF: EEPROM fault
7.DEF: Watchdog activation
8.DEF: Signal outside upper limit
10.DEF: Injector control
11.DEF: Injector control capacitor fault
12.DEF: Injection fault when decelerating
13.DEF: Initialisation error
14.DEF: Open circuit or internal electronic fault.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after one attempt to start the engine, or with the engine
running.
Special notes:
If 6.DEF, 8.DEF, 12.DEF is present the level 1 warning light is lit.
If one of the other faults is present, the level 2 warning light is lit.
If 6.DEF is present, the OBD warning light will come on after three consecutive driving
cycles (starting + 5 seconds, switch off the ignition and wait for 1 minute).
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
Priority when dealing with a number of faults:
Deal with fault DF046: Battery voltage first if it is present or stored.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF038/EDC16_V58_DF038/EDC16_V5C_DF038/EDC16_V18_DF038/EDC16_V1C_DF038/EDC16_V20_DF038
Page 66 of 365

13B-66
MR-372-J84-13B200$288.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF039
PRESENT
OR
STOREDINLET AIR TEMPERATURE SENSOR CIRCUIT
CO.1: Open circuit or short circuit to + 12 V
CC.0: Short circuit to earth
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after one attempt to start the engine, or with the engine
running.
Special notes:
If the fault is present:
– the air temperature value enters defect mode, i.e. PR059 Inlet air temperature =
20°C,
– the EGR function is inhibited,
– the level 2 warning light is lit.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
CO.1
NOTESNone
Check the air flowmeter connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity of connection 3FB between components 799 and 597.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the continuity and insulation from + 12 V of the following connections:
– connection code 3B,
– connection code3DW,
– connection code 3KJ,
– connection code 3DU.
between components 120 and 799.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of the air temperature sensor between connections 3B and 3DW of the air flowmeter.
Replace the air flowmeter if the resistance displayed is not:
3553 Ω < X < 3875 Ω at 10°C
2352 Ω < X < 2544 Ω at 20°C
1612 Ω < X < 1730 Ω at 30°C
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF039/EDC16_V58_DF039/EDC16_V5C_DF039/EDC16_V18_DF039/EDC16_V1C_DF039/EDC16_V20_DF039
Page 68 of 365

13B-68
MR-372-J84-13B200$288.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF040
PRESENT
OR
STOREDCYLINDER 1 INJECTOR CIRCUIT
CC.1: Short circuit to +12 V
CO: Open circuit
CC: Short circuit
1.DEF: Injector control
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine has been started.
Special notes:
If CO.1, CC or 1.DEF is present, the level 2 warning light is lit.
If CO is present, the level 1 warning light is lit.
If CO is present, the OBD warning light will come on after three consecutive driving
cycles (starting + 5 seconds, switch off the ignition and wait for 1 minute).
If the fault is present, the injection on cylinder 1 is disabled.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
IMPORTANT
This fault can result in a rapid and significant fouling of the particle filter.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This test enables the condition and the conformity of the engine wiring harness to be checked.
CC.1
CO
CC
1.DEF
NOTESNone
Check the connections on injector no 1.
Check the injection computer connections.
Repair if necessary.
Disconnect injector no. 1.
Measure the resistance of injector no. 1 between connections 3CR and 3KW.
Replace the injector if it has a short circuit (R = 0 Ω) or open circuit (infinite resistance measurement).
Otherwise reconnect injector no. 1.
Check the continuity and absence of interference resistance of the following connections:
– connection codes 3CR and 3KW between components 120 and 193.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, run test 9: Poor injector operation.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF040/EDC16_V58_DF040/EDC16_V5C_DF040/EDC16_V18_DF040/EDC16_V1C_DF040/EDC16_V20_DF040
Page 69 of 365

13B-69
MR-372-J84-13B200$288.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF041
PRESENT
OR
STOREDCYLINDER 2 INJECTOR CIRCUIT
CC.1: Short circuit to +12 V
CO: Open circuit
CC: Short circuit
1.DEF: Injector control
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine has been started.
Special notes:
If CO.1, CC or 1.DEF is present, the level 2 warning light is lit.
If CO is present, the level 1 warning light is lit.
If CO is present, the OBD warning light will come on after three consecutive driving
cycles (starting + 5 seconds, switch off the ignition and wait for 1 minute).
If the fault is present, the injection on cylinder 2 is inhibited.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
IMPORTANT
This fault can result in a rapid and significant fouling of the particle filter.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This test enables the condition and the conformity of the engine wiring harness to be checked.
CC.1
CO
CC
1.DEF
NOTESNone
Check the connections on injector no. 2.
Check the injection computer connections.
Repair if necessary.
Disconnect injector no. 2.
Measure the resistance of injector no. 2 between connections 3KX and 3CS.
Replace the injector if it has a short circuit (R = 0 Ω) or open circuit (infinite resistance measurement).
Otherwise reconnect injector no. 2.
Check the continuity and absence of interference resistance of the following connections:
– connection codes 3KX and 3CS between components 120 and 194.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, run test 9 Poor injector operation.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF041/EDC16_V58_DF041/EDC16_V5C_DF041/EDC16_V18_DF041/EDC16_V1C_DF041/EDC16_V20_DF041