climate control RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals Siemens Injection Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2011, Model line: SCENIC, Model: RENAULT SCENIC 2011 J95 / 3.GPages: 329, PDF Size: 1.71 MB
Page 152 of 329
13B-152
MR-372-J84-13B050$585.mif
V17
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2DIESEL INJECTION
Fault finding – Interpretation of statuses13B
ET088
REQUEST TO START COMPRESSOR
STATUS DEFINITION"ACTIVE": This status indicates that the compressor activation request is active.
"INACTIVE": This status indicates that the compressor activation request is not active.
NOTESSpecial notes:
Only perform these tests if the status does not correspond with the system
programming functions.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant temperature
>80 °C
ACTIVE
Status ET088 becomes ACTIVE if there has been a request for air conditioning (press
on AC or AUTO button, with maximum cold request) and status ET004 is YES.
The selection is made on the air conditioning control panel, the request for air
conditioning is transmitted to the UCH which in turn transmits the request to the
injection computer which either authorises or does not authorise compressor activation.
If the injection computer authorises compressor switch-on, the injection computer
sends the compressor switch-on request to the UPC and status ET088 becomes
""ACTIVE" (Climate control).
If the vehicle is equipped with manual air conditioning, the air conditioning request is
transmitted from the air conditioning control panel to the UCH which then accepts or
does not accept the air conditioning compressor coming on depending on the operating
status of the passenger compartment fan. When the request has been accepted, the
request to switch on the compressor is transmitted to the injection computer which
either authorises or does not authorise the compressor to start.
If the injection computer authorises compressor switch-on, it sends the request for
compressor switch-on to the UPC and status ET088 becomes "ACTIVE".
If there has been no compressor switch-on request and status ET088 remains
"ACTIVE", see62A, Air conditioning.
Note: Compressor operation is only authorised when the engine is running.
Compressor activation is commanded by the UPC.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
SID301_V44_ET088/SID304_V45_ET088/SID301_V48_ET088/SID304_V49_ET088/SID304_V4D_ET088/SID301_V4C_ET088
Page 209 of 329
13B-209
MR-372-J84-13B050$702.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of parameters
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
PR076
REFRIGERANT SENSOR VOLTAGE
PARAMETER
DEFINITIONThis parameter indicates the refrigerant fluid sensor voltage in volts.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
Conformity check with the engine stopped and the ignition on, or the engine running and the engine
coolant temperature > 80°C
0 V ≤ PR076 ≥ 5 V
Carry out fault finding on the climate control computer (see 62B, Climate control).
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_PR076/SID304_V45_PR076/SID301_V48_PR076/SID304_V49_PR076/SID304_V4D_PR076/SID301_V4C_PR076