df898 RENAULT SCENIC 2012 J95 / 3.G Engine And Peripherals EDC16CP33 Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2012, Model line: SCENIC, Model: RENAULT SCENIC 2012 J95 / 3.GPages: 510, PDF Size: 2.98 MB
Page 30 of 510
13B-30V12 MR-372-J84-13B300$060.mif
DIESEL INJECTION
Fault finding – Fault summary table13B
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
* temp: Temperature
* Diff: Differential
* regen.: RegenerationTool faultAssociated
DTCDiagnostic tool title
DF3152452 Particle filter diff.* pressure sensor
DF3232100 Damper valve
DF333C101 Injection -> automatic gearbox connection
DF364530 Air conditioning
DF502565 Cruise control or speed limiter button
DF5322502 Alternator charge signal
DF5692263 Turbocharging circuit
DF6452101 Damper valve position regulation
DF646120 Damper valve position sensor
DF647488 EGR valve position regulation
DF651470 Turbine upstream pressure sensor circuit
DF652544 Turbine upstream temperature sensor circuit
DF7172453 Particle filter upstream pressure
DF890297 Movement during particle filter regener*
DF8912146 Group 1 injectors feed
DF8922149 Group 2 injectors feed
DF8952293 Pressure regulation on rail
DF89689 Pressure regulation on pump
DF89790 Pressure regulator circuit on pump
DF8982294 Pressure regulator circuit on rail
DF8993031 Regeneration temperature limit exceeded
DF9971640 Control unit -> thermoplunger connection
DF1020253F Engine oil dilution
DF10691670 Heater plugs not configured
DF118812B Air leak in turbocharging circuit
Page 240 of 510
13B-240
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF895
PRESENT
OR
STOREDPRESSURE REGULATION ON RAIL1.DEF: Below minimum threshold
2.DEF: Above maximum threshold
3.DEF: Negative loop deviation
4.DEF: Positive loop deviation
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on,
– with the engine running,
– road test.
Priorities when dealing with a number of faults:
– DF898 Pressure regulator circuit on rail,
– DF897 Pressure regulator circuit on pump,
– DF896 Pressure regulation on pump.
Special notes:
DF895 depends on the pressure regulator built into the rail (DRV).
DF896 Pressure regulation on pump depends on the pressure regulator integrated
in the pump (MPROP).
The fuel pressure regulator built into the rail (DRV) and the fuel pressure regulator built
into the pump (MPROP) are never actuated at the same time.
If the fault is present:
– particle filter regeneration is inhibited,
– the engine stops and the level 2 warning light comes on: 1.DEF, 4.DEF,
–the level 1 warning light comes on: 2.DEF, 3.DEF, 4.DEF,
– engine torque limited 2.DEF, 3.DEF, 4.DEF,
– the rail pressure is regulated by a regulator built into the pump (MPROP): 2.DEF,
3.DEF, 4.DEF.
Use bornier Elé.1681 for all operations on the engine management computer.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
EDC16CP33_V18_DF895 / EDC16CP33_V1C_DF895 / EDC16CP33_V54_DF895 / EDC16CP33_V20_DF895 / EDC16CP33_V58_DF895 /
EDC16CP33_V5C_DF895 / EDC16CP33_V24_DF895 / EDC16CP33_V04_DF895 / EDC16CP33_V08_DF895 / EDC16CP33_V44_DF895 /
EDC16CP33_V4C_DF895 / EDC16CP33_V34_DF895 / EDC16CP33_V38_DF895 / EDC16CP33_V74_DF895 / EDC16CP33_V28_DF895 /
EDC16CP33_V62_DF895 / EDC16CP33_V26_DF895 / EDC16CP33_V60_DF895
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 242 of 510
13B-242
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF895
CONTINUED 2
If the diesel does not behave in accordance with this description, replace the rail (removing the rail pressure
regulator (DRV) is not permitted).
Note: the above description no longer applies if faults DF898 Rail pressure regulator circuit, DF897 Pump
pressure regulator circuit and DF896 Pump pressure regulation are present.
Check the condition of the pressure regulator connector on the pump (MPROP) (see Wiring Diagram Technical
Note, Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1105).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance between connections 3FB and 3HI of component 1105.
If the resistance of the pressure regulator connector on the pump is not between 2 Ω < X < 6 Ω at 20°C, contact
the Techline.
If the fault is still present, contact the Techline.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 243 of 510
13B-243
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF896
PRESENT
OR
STOREDPRESSURE REGULATOR ON PUMP1.DEF: Below minimum threshold
2.DEF: Above maximum threshold
3.DEF: Negative loop deviation
4.DEF: Positive loop deviation
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on.
– engine running.
Priorities when dealing with a number of faults:
– DF897 Pressure regulator circuit on pump
– DF898 Pressure regulator circuit on rail
Special notes:
If the fault is present:
– particle filter regeneration is inhibited,
– the engine stops and the level 2 warning light comes on: 1.DEF,
–the level 1 warning light comes on: 2.DEF, 3.DEF, 4.DEF,
– engine torque is limited: 2.DEF, 3.DEF, 4.DEF,
– the rail pressure is regulated by a regulator built into the rail (DRV): 2.DEF, 3.DEF,
4.DEF.
1.DEF
2.DEF
3.DEF
4.DEF
NOTESNone.
Check that there are no leaks on the high pressure diesel fuel circuit.
Repair if necessary.
Check the level of fuel in the tank.
Check the low pressure circuit using Test 3 Low pressure circuit test and check that there are no exterior air
leaks in the low pressure fuel circuit.
EDC16CP33_V18_DF896 / EDC16CP33_V1C_DF896 / EDC16CP33_V54_DF896 / EDC16CP33_V20_DF896 / EDC16CP33_V58_DF896 /
EDC16CP33_V5C_DF896 / EDC16CP33_V24_DF896 / EDC16CP33_V04_DF896 / EDC16CP33_V08_DF896 / EDC16CP33_V44_DF896 /
EDC16CP33_V4C_DF896 / EDC16CP33_V34_DF896 / EDC16CP33_V38_DF896 / EDC16CP33_V74_DF896 / EDC16CP33_V28_DF896 /
EDC16CP33_V62_DF896 / EDC16CP33_V26_DF896 / EDC16CP33_V60_DF896
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 249 of 510
13B-249
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF898
PRESENT
OR
STOREDPRESSURE REGULATOR CIRCUIT ON RAILCO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault reappears after:
– the ignition is switched on,
– the regulator is controlled using command AC225 Rail pressure regulator.
Special notes:
The rail pressure regulator (DRV) is built into the high pressure rail.
The DF898 Rail pressure regulator circuit depends on the pressure regulator on the
rail (DRV).
If the fault is present:
– the quantity of fuel injected is limited and the engine speed is limited to 3000 rpm:
CO, CC.1, 1.DEF,
–the level 2 warning light will be lit,
– the engine stops immediately for CO, CC.1, 1.DEF,
– the engine stops after a few minutes for CC.0,
– the rail pressure is regulated by the pump pressure regulator (MPROP).
Use bornier Elé. 1681 for all operations on the engine management computer
connectors.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
EDC16CP33_V18_DF898 / EDC16CP33_V1C_DF898 / EDC16CP33_V54_DF898 / EDC16CP33_V20_DF898 / EDC16CP33_V58_DF898 /
EDC16CP33_V5C_DF898 / EDC16CP33_V24_DF898 / EDC16CP33_V04_DF898 / EDC16CP33_V08_DF898 / EDC16CP33_V44_DF898 /
EDC16CP33_V4C_DF898 / EDC16CP33_V34_DF898 / EDC16CP33_V38_DF898 / EDC16CP33_V74_DF898 / EDC16CP33_V28_DF898 /
EDC16CP33_V62_DF898 / EDC16CP33_V26_DF898 / EDC16CP33_V60_DF898
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 250 of 510
13B-250
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF898
CONTINUED 1
CONOTESNone.
Check the condition of the rail pressure regulator connector (DRV) (see Wiring Diagram Technical Note, Laguna
II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1198).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance between connections 3FB and 3RG of component 1198.
If the resistance of the rail pressure regulator connector is less than 2 Ω or greater than 1 kΩ, contact the Techline.
Check the continuity of the following connection:
•3RG between components 120 and 1198.
Check the +12 V after relay supply to the rail pressure regulator (DRV) on the following connection:
•3FB of component 1198.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, contact the Techline.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 251 of 510
13B-251
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF898
CONTINUED 2
CC.0NOTESNone.
Check the condition of the rail pressure regulator connector (DRV) (see Wiring Diagram Technical Note, Laguna
II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1198).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance between connections 3FB and 3RG of component 1198.
If the resistance of the rail pressure regulator connector is less than 2 Ω or greater than 1 kΩ, contact the Techline.
Check the continuity and insulation from earth of the following connection:
•3RG between the components 120 and 1198.
Check the +12 V after relay supply to the rail pressure regulator (DRV) on the following connection:
•3FB of component 1198.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, contact the Techline.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 252 of 510
13B-252
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF898
CONTINUED 3
CC.1NOTESNone.
Check the condition of the rail pressure regulator connector (DRV) (see Wiring Diagram Technical Note, Laguna
II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1198).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance between connections 3FB and 3RG of component 1198.
If the resistance of the rail pressure regulator connector is less than 2 Ω or greater than 1 kΩ, contact the Techline.
Check the continuity and insulation from + 12 V of the following connection:
•3RG between the components 120 and 1198.
Check the +12 V after relay supply to the rail pressure regulator (DRV) on the following connection:
•3FB of component 1198.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, contact the Techline.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 253 of 510
13B-253
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF898
CONTINUED 4
1.DEFNOTESSpecial notes:
This fault appears when the computer control section has
overheated.
Check the condition of the rail pressure regulator connector (DRV) (see Wiring Diagram Technical Note, Laguna
II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1198).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance between connections 3FB and 3RG of component 1198.
If the resistance of the rail pressure regulator connector is less than 2 Ω or greater than 1 kΩ, contact the Techline.
Check the continuity and absence of interference resistance on the following connection:
•3RG between the components 120 and 1198.
Check the +12 V after relay supply to the rail pressure regulator (DRV) on the following connection:
•3FB of component 1198.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, contact the Techline.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 332 of 510
13B-332
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
V12 MR-372-J84-13B300$121.mif
DIESEL INJECTION
Fault finding – Interpretation of parameters13B
PR006RAIL PRESSURE REGULATOR CURRENT
PARAMETER
DEFINITIONThis parameter indicates the current absorbed by the rail pressure regulator in mA.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
Conformity check: Engine stopped and ignition on, or Engine running, and engine coolant
temperature > 80°C
This parameter indicates the current absorbed by the rail pressure regulator PR006 ≈ PR007 Rail pressure
regulator current setpoint.
In the event of a fault, consult the interpretation of fault DF898 Rail pressure regulator circuit.
EDC16CP33_V18_PR006 / EDC16CP33_V1C_PR006 / EDC16CP33_V54_PR006 / EDC16CP33_V20_PR006 / EDC16CP33_V58_PR006 /
EDC16CP33_V5C_PR006 / EDC16CP33_V24_PR006 / EDC16CP33_V04_PR006 / EDC16CP33_V08_PR006 / EDC16CP33_V44_PR006 /
EDC16CP33_V4C_PR006 / EDC16CP33_V34_PR006 / EDC16CP33_V38_PR006 / EDC16CP33_V74_PR006 / EDC16CP33_V28_PR006 /
EDC16CP33_V62_PR006 / EDC16CP33_V26_PR006 / EDC16CP33_V60_PR006
EDC16CP33
Program No.: C4
VDiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74