62B-38
MR-413-X44-62B000$460_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
SUB-FUNCTION: PASSENGER COMPARTMENT VENTILATION (CONTINUED)
NOTESOnly carry out this conformity check after a full check using the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine running, (12 V APC) AIR CONDITIONING ON 
(air conditioning compressor activated).
FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
TemperaturesPR001:Interior 
temperatureX = interior 
temperature ± 5 ˚C
(invalid value: 87.5 ˚C)In the event of a fault, see the 
interpretation of this 
parameter.
PR002:External 
temperatureX = exterior 
temperature ± 5 ˚C
(invalid value: 215 ˚C)In the event of a fault, see the 
interpretation of this 
parameter. 
Note: 
This parameter is displayed via 
the climate control computer but 
is generated by the UCH. 
Page 39 of 99

62B-39
MR-413-X44-62B000$460_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
COLD LOOP SUB-FUNCTION
NOTESOnly carry out this conformity check after a full check using the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning 
compressor activated).
FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
Request to activate 
the compressorET140:Air conditioning 
requestACTIVE In the event of a fault, refer to the 
interpretation of this status.
Passenger 
compartment 
blowerET141:Passenger 
compartment 
blowerRUNNINGIn the event of a fault, refer to the 
interpretation of this status.
CompressorET020:Compressor 
controlACTIVEIn the event of a fault, refer to the 
interpretation of this status.
TemperaturePR001:Interior 
temperatureX = interior 
temperature ± 5 ˚C 
(invalid value: 87.5 ˚C)In the event of a fault, see the 
interpretation of this 
parameter.
PR002:External 
temperatureX = exterior 
temperature ± 5 ˚C
 (invalid value: 215 ˚C)In the event of a fault, see the 
interpretation of this 
parameter
Note: 
This parameter is displayed via 
the climate control computer but 
is generated by the UCH.
Air flapsPR012:Mixing flap 
positionFrom 0 % (“Maximum 
cold” position: 15 ˚C)
to 100 % (“Maximum 
hot” position: 27 ˚C).In the event of a fault, see the 
interpretation of this 
parameter. 
Page 40 of 99

62B-40
MR-413-X44-62B000$460_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
HEATING SUB-FUNCTION
NOTESOnly carry out this conformity check after a full check using the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning 
compressor activated).
Order FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
1Heated rear 
screenET086: Heated rear 
screen: manual 
modeACTIVE: De-icing 
request using the control 
button.
INACTIVE otherwise.In the event of a fault, refer 
to the interpretation of this 
status.
ET085:Heated rear 
screen: 
automatic modeACTIVE: De-icing 
request using the control 
button. (“see clear” 
function)
INACTIVE otherwise.In the event of a fault, refer 
to the interpretation of this 
status.
2Passenger 
compartment 
blowerET141:Passenger 
compartment 
blowerRUNNINGIn the event of a fault, refer 
to the interpretation of this 
status.
3Air mixing 
motorPR012:Mixing flap 
positionFrom 0 % (“Maximum 
cold” position: 15 ˚C
to 100 % = “Maximum 
hot” position: 27 ˚C).In the event of a fault, see 
the interpretation of this 
parameter.
4HeatingPR045:Current heating 
resistor power0 < X < 900  WIn the event of a fault, see 
the interpretation of this 
parameter.
5TemperaturePR001:Interior 
temperatureX = interior 
temperature ± 5 ˚C
(invalid value: 87.5 ˚C)In the event of a fault, see 
the interpretation of this 
parameter.
PR002: External 
temperatureX = exterior 
temperature ± 5 ˚C 
(invalid value: 215 ˚C)In the event of a fault, see 
the interpretation of this 
parameter
Note: 
This parameter is displayed 
via the climate control 
computer but is generated 
by the UCH.
PR004:Coolant 
temperatureX = engine coolant 
temperature in ˚C.In the event of a fault, see 
the interpretation of this 
parameter. 
Page 41 of 99

62B-41
MR-413-X44-62B000$460_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Fault finding - Conformity check62B
MAIN SCREEN
NOTESOnly carry out this conformity check after a full check using the diagnostic tool 
(fault reading and configuration checks).
Application conditions: engine running, AIR CONDITIONING ON (air conditioning 
compressor activated).
This page lists the statuses and parameters provided by the climate control computer 
but which are not associated with the three sub-functions given in the conformity 
check (PASSENGER COMPARTMENT VENTILATION, COLD LOOP and HEATING 
sub-functions).
Order FunctionParameter or Status 
checked or ActionDisplay and Notes Fault finding
1Electrical 
suppliesPR092:Battery voltage10.5 V < X <14.4 VIn the event of a fault, see 
the interpretation of this 
parameter.
ET083:+ 12 V after 
ignition present PRESENT:
 Ignition on.In the event of a fault, refer 
to the interpretation of this 
status.
ET002:+ 12 V side 
lightsABSENT: Side lights off. 
PRESENT: Side lights 
on.In the event of a fault, refer 
to the interpretation of this 
status.
PR122:Night lighting 
levelBetween 15 % (minimum 
lighting level) and 99 % 
(maximum lighting level) 
(side lights off: 102 %)In the event of a fault, 
consult the interpretation 
of this parameter 
Note: 
This parameter is displayed 
by the climate control 
computer but is generated 
by the instrument panel. 
Page 43 of 99

62B-43
MR-413-X44-62B000$506_eng.mif
V1
CLIMATE CONTROL
Fault finding - Status summary table
                            
Vdiag No.: 44
62B
ET002
+ 12 V SIDE LIGHTS FEED
NOTESNone
This status indicates the presence of + 12 V side lights feed on connection LPD of component 419.
If ET002 displays ABSENT when the side light are lit, check for + 12 V between connection LPD and the earth 
connection NAM of component 419.
If + 12 V is present on connection LPD and ET002 displays ABSENT.
If the status does not operate, carry out fault finding on the UCH (see 87B, UCH).
If + 12 V is not present on connection LPD, consult ALP No. 13.
AFTER REPAIRRepeat the conformity check from the start.
CLIM_V44_ET012 
Page 44 of 99

62B-44
MR-413-X44-62B000$506_eng.mif
V1
CLIMATE CONTROL
Fault finding - Status summary table
                            
Vdiag No.: 44
62B
ET020
COMPRESSOR CONTROL
NOTESNone
This indicates the status of the compressor actuated by the injection computer.
If ET020 displays ACTIVE, the compressor activation request is authorised.
If ET020 displays INACTIVE, the compressor activation request is not authorised.
If the “AC” indicator light is lit and if ET020 displays INACTIVE, run fault finding on the injection computer 
(see 13B, Diesel injection or 17B, Petrol injection) and UCH (see 87B, UCH).
AFTER REPAIRRepeat the conformity check from the start.
CLIM_V44_ET020 
Page 45 of 99

62B-45
MR-413-X44-62B000$552_eng.mif
V1
62B
CLIMATE CONTROL
Fault finding - Interpretation of statuses
ET062
RECIRCULATION FLAP POSITION
NOTESSpecial notes
In extreme temperatures (above 35 ˚C) and when the climate control is switched on, 
the recirculation flap sets itself to the recirculation position in order to correct the 
passenger compartment temperature more quickly.
This status specifies the position of the recirculation flap.
If the flap is in the exterior air position, the status displays OPEN.
If the flap is in the recirculation position, the status displays CLOSED.
If the status does not operate as indicated, apply the interpretation of fault DF021 Recirculation motor circuit.
AFTER REPAIRRepeat the conformity check from the start.
CLIM_V44_ET062
                  
Vdiag No.: 44
MR-413-X44-62B000$552_eng.mif 
Page 46 of 99

62B-46
MR-413-X44-62B000$552_eng.mif
V1
CLIMATE CONTROL
Fault finding - Interpretation of statuses
                            
Vdiag No.: 44
62B
ET083
+ 12 V AFTER IGNITION PRESENT
NOTESUse the Wiring Diagram Technical Note for the New Twingo.
This status indicates activation of + 12 V APC by the UCH via the multiplex line.
When the ignition is off, the status displays ABSENT. 
When the ignition is on, the status displays PRESENT.
If the status does not operate, carry out fault finding on the UCH (see 87B, UCH).
AFTER REPAIRRepeat the conformity check from the start.
CLIM_V44_ET083 
Page 47 of 99

62B-47
MR-413-X44-62B000$552_eng.mif
V1
CLIMATE CONTROL
Fault finding - Interpretation of statuses
                            
Vdiag No.: 44
62B
ET085
HEATED REAR SCREEN: AUTO MODE
NOTESNone
This status specifies whether the heated rear screen is operated in automatic mode or not. This mode 
corresponds to the SEE CLEAR function. This function switches on the heated rear screen, the heated door 
mirrors, the air conditioning and the windscreen ventilation. The heating and air conditioning system requires a 
short amount of time between the request and blower activation in order for dry air to be blown. The heated rear 
screen will operate for as long as the SEE CLEAR function is requested (permanently controlled). This automatic 
mode is obtained by pressing the de-icing button at the top of the air conditioning control panel.
If the SEE CLEAR function is requested, the status should display ACTIVE.
If the SEE CLEAR function is not requested, the status should display INACTIVE.
If the status does not operate as indicated (see ALP10 Poor de-icing efficiency - rear screen demisting).
AFTER REPAIRRepeat the conformity check from the start.
CLIM_V44_ET085 
Page 48 of 99

62B-48
MR-413-X44-62B000$552_eng.mif
V1
CLIMATE CONTROL
Fault finding - Interpretation of statuses
                            
Vdiag No.: 44
62B
ET086
HEATED REAR SCREEN: MANUAL MODE
NOTESNone
This status specifies whether the request for the heated rear screen is being operated in manual mode. This mode 
corresponds to a timed operating period for the heated rear screen, controlled by the UCH. This time delay 
depends on the exterior temperature (between 10 and 15 minutes).
Operation in manual mode is obtained by pressing the de-icing button at the bottom of the air conditioning control 
panel. This function is used to switch on the heated rear screen and the heated door mirrors.
If activation of the heated rear screen is requested in manual mode, the status should display ACTIVE.
If activation of the heated rear screen is not requested, the status should display: INACTIVE.
If the status does not operate as indicated (see ALP10 Poor de-icing efficiency - rear screen demisting).
AFTER REPAIRRepeat the conformity check from the start.
CLIM_V44_ET086