Diagnostic - Fault finding chart62B
ALP 8
CONTINUED 3
Carry out fault finding on the injection system to ensure that no fault is present (if faults are displayed by the injection 
computer, engagement of the air conditioning may be inhibited). If there are present or stored faults, carry out the necessary 
repairs (see 13B, Diesel injection or 17B, Petrol injection).
Check that the refrigerant fluid pressure is correct (neither too low nor too high) using the PR037 Refrigerant fluid 
pressure parameter (see Conformity check, Cold loop sub-function).
Check that the engine cooling fan assembly is at speed 1 by 
viewing the following status on the cold loop sub-function 
screen:
- Status ET022 Low-speed fan assembly request should 
display ACTIVE.
Note: 
These statuses are not displayed by all types of injection 
(see Conformity check, Cold loop sub-function).
Does the engine cooling fan operate at low speed?
YES
NO
Using the diagnostic tool, run command 
AC154 Low speed fan assembly relay.
Does the engine cooling fan operate at 
low speed?
NO YES
Connector of component 321 disconnected. Connect a test 
light between connection 49L of component 321 and the 
chassis earth and run command AC154 Low speed fan 
assembly relay.
Does the test light illuminate?
              YES              NO
Carry out fault finding 
on the injection 
system (sub-function: 
cold loop and engine 
cooling for low speed 
fan assembly 
activation).
Measure the resistance of component 321, between connections 
49L and 49B of component 321. If the resistance measured is 
infinite, replace the fan assembly resistor (component 321).D
AFTER REPAIRCarry out a complete check with the diagnostic tool. 
Page 89 of 99

62B-89
MR-413-X44-62B000$920_eng.mif
V1
62B
CLIMATE CONTROL
Diagnostic - Fault finding chart
ALP 10 Inefficient rear screen de-icing/demisting
NOTESCarry out this conformity check after a full check using the diagnostic tool 
(fault reading, especially UCH and injection faults and configuration checks).
Check that the fuses are sound.
Use a multimeter and a 21 W test light.
Use the Wiring Diagram Technical Note, NEW TWINGO.
Special notes:
Check that the inside of the windows are not greasy as this reduces the efficiency of 
the de-icing.
Note:
The de-icing control is only authorised when the engine is running to save power. 
The rear screen de-icer control is activated by pressing the de-icing button at the 
bottom of the climate control panel in manual mode (with time delay and rear-view 
mirror de-icer).
Ensure that there are no water leaks in the passenger compartment which would significantly increase the 
moisture and reduce the effectiveness of the demisting function (see ALP 12 if the fault is noted).
Is the fault still present?
                                      YES NO
Check that the UCH is correctly configured by viewing the configuration reading LC013 Type of air conditioning. 
Reconfigure the UCH if necessary.
Check that the UCH receives the signal about the 
status and operation of the engine. In the Cold Loop 
screen, status ET142 "engine operating phase" 
should display RUNNING.
Is status ET142 RUNNING?
YES
End of fault finding procedure.
NOCarry out fault finding on the UCH 
(interpretation of status ET142) and on the 
multiplex network.
AFTER REPAIRCarry out a complete check with the diagnostic tool.
                  
Vdiag No.: 44
MR-413-X44-62B000$920_eng.mif 
Page 93 of 99

62B-93
MR-413-X44-62B000$920_eng.mif
V1
                            
Vdiag No.: 44CLIMATE CONTROL
Diagnostic - Fault finding chart62B
ALP 13 Lighting fault on the control panel in night mode
NOTESOnly consult this customer complaint after a complete check of the multiplex 
network and the air conditioning with the diagnostic tool.
Special notes:
With the ignition on, the control panel screen is permanently on but the panel buttons 
only light up when the side lights are switched on.
Note:
If the exterior temperature sensor is faulty, the climate control computer is 
activated 5 seconds after the ignition is switched on (the UCH performs fault 
finding on the exterior temperature sensor).
Use the Wiring Diagram Technical Note for the New Twingo.
Is the fault shared with other components (first row cigarette lighter, radio, multifunction display, cruise control/
speed limiter on off switch, etc.)
YES NO
Switch on the ignition and the side lights.
Using the diagnostic tool and the conformity 
check, check that the lighting dimmer is operating 
correctly using parameter PR122 NIGHT TIME 
LIGHTING LEVEL.
Does the parameter vary?
YES
Check the connection and condition of the 
connector of component 419.
If there is a repair method (see Technical Note 
6015A, Electrical wiring repair, Wiring: Repair 
precautions), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
NOCarry out a fault finding procedure of the 
instrument panel.
Run a multiplex network test (see 88B, 
Multiplex).
AFTER REPAIRCarry out a complete check with the diagnostic tool.