MANUAL AIR CONDITIONING
Fault finding - Conformity check62C
SUB-FUNCTION: HEATING
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped, ignition on, AIR CONDITIONING
SWITCHED OFF (Passenger compartment blower unit switched off and air
conditioning compressor not activated).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
UCH (see 87B,
Passenger
compartment
connection unit)ET015:Passenger
compartment
blowerINACTIVE
(according to test
conditions: see Notes).In the event of a fault, refer to the
interpretation of this status.
PR001:Battery voltage10.5 V < X <14.4 VIf there is a fault, refer to the
interpretation of this
parameter If the fault is still
present, carry out fault finding on
the charging circuit (see MR 411
Mechanical, 16A, Starting -
Charging).
PR002:Exterior
temperature
(depending on
the version)X = exterior
temperature ±± ± ±
5 ˚C
(invalid value: 215 ˚C).If there is a fault, refer to the
interpretation of this
parameter
PR024:Engine coolant
temperatureX = engine coolant
temperature in ˚C.If there is a fault, refer to the
interpretation of this
parameter
ET239:Ignition switch
position+ after ignition feedIn the event of a fault, refer to the
interpretation of this status.
PR025:Engine speed0 rpmIf there is a fault, refer to the
interpretation of this
parameter
Page 31 of 63

62C-31
MR-413-X44-62C000$637_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Conformity check62C
SUB-FUNCTION: HEATING
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine at idle speed, AIR CONDITIONING OPERATING
(air conditioning compressor engaged).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
UCH (continued)
(see 87B,
Passenger
compartment
connection unit)ET239:Ignition switch
position+ after ignition feedIn the event of a fault, refer to the
interpretation of this status.
PR025:Engine speed800 rpm ± 50 rpmIn the event of a fault, see the
interpretation of this
parameter.
PR024:Engine coolant
temperatureX = engine coolant
temperatureIn the event of a fault, see the
interpretation of this
parameter.
ET015:Passenger
compartment
blowerACTIVE
(according to test
conditions: see Notes).In the event of a fault, refer to the
interpretation of this status.
Note: This status only operates
for manual air conditioning and
heating versions.
PR001:Battery voltage12.5 V < X < 14.4 VIn the event of a fault, see the
interpretation of this
parameter.
If the fault is still present, carry
out fault finding on the charging
circuit (see MR 411 Mechanical,
16A, Starting - Charging).
PR002:Exterior
temperature
(depending on
the version)X = exterior
temperature ±± ± ±
5 ˚C
(invalid value: 215 ˚C).In the event of a fault, see the
interpretation of this
parameter.