ABS RENAULT TWINGO RS 2009 2.G Electrical Equipment - Petrol Injection User Guide
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: TWINGO RS, Model: RENAULT TWINGO RS 2009 2.GPages: 348
Page 83 of 348
17B-83V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF079
CONTINUED 2
Look for possible damage to the wiring harness.
Check the condition of the engine management computer connector (component code 120).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
If the fault is still present, disconnect the battery and the injection computer.
Check the insulation, continuity and absence of interference resistance on the following connections:
●3AJB between the components 120 and 1076, and 3AJC between the components 120 and 1076,
●3MP between the components 120 and 1076,
●3MN between the components 120 and 1076,
●3MQ between the components 120 and 1076,
●3MO between the components 120 and 1076.
●3LR between the components 120 and 921,
●3LS between the components 120 and 921,
●3LT between the components 120 and 921,
●3LU between the components 120 and 921,
●3LW between the components 120 and 921,
●3LV between the components 120 and 921.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRIf the throttle valve has been replaced, program the throttle stops (see Configurations
and programming).
Follow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 85 of 348
17B-85V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF081
PRESENT
OR
STOREDCANISTER BLEED SOLENOID VALVE CIRCUITCO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: EOBD
NOTESPriorities when dealing with a number of faults:
Deal with the faults DF084 Actuator relay control circuit and DF046 Battery voltage
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running or when running the command
AC017 Bleed canister solenoid.
Special notes:
CO/CC.1: The valve remains stuck shut and there is a smell of fuel. The OBD warning
light is illuminated.
CC.0: The valve remains stuck open: hesitation when driving, risk of engine stalling and
difficult to restart the engine.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Check the condition of the fuel vapour absorber bleed solenoid valve connector (component code 371).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance of the fuel vapour absorber bleed solenoid between the connections 3FB and 3BB:
If the resistance of the fuel vapour absorber bleed solenoid valve is not between:
●22 Ω < X < 30 Ω at 23˚C, replace the solenoid valve.
Check, with the ignition on, that there is + 12V on the connection 3FB for the fuel vapour absorber bleed solenoid,
component code 371.
If there is no + 12 V:
–Disconnect the battery
SIM32_V44_DF081/SIM32_V4C_DF081/SIM32_V50_DF081/SIM32_V54_DF081
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 86 of 348
17B-86V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF081
CONTINUED 1
For NEW TWINGO or E33:
–Disconnect the injection locking relay connector, component code 238,
–Check the condition of the injection locking relay connector, component code 238.
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the connector, otherwise change the wiring.
Reconnect the injection locking relay connector and reconnect the battery.
With the ignition on, if there is still not + 12V on the connector for the fuel vapour absorber bleed solenoid, there is
a fault in the engine fuse and relay box.
Perform fault finding for the engine fuse and relay box while checking the continuity of the following connection:
●BP17 between components 120 and 597,
●BP17 between components 1033 and 597.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, check the battery and run fault finding on the charging circuit (see Technical Note 6014A,
Checking the charging circuit).
Use the universal bornier to check the insulation and continuity of the following connection:
●3FB between the components 371 and 238.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 87 of 348
17B-87V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF081
CONTINUED 2
For CLIO III or MODUS:
Check the condition of the Protection and Switching Unit (component code 1337).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the connector, otherwise change the wiring.
Use the universal bornier to check the insulation and continuity of the following connection:
●3FB between the components 371 and 1337.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Reconnect the Protection and Switching Unit connector and reconnect the battery.
With the ignition on, if there is still no +12 V on the connector for the fuel vapour absorber canister bleed solenoid
valve, there is a fault in the Protection and Switching Unit (UPC).
Run fault finding on the UPC, component code 1337 (see 87G, Engine Compartment Connection Unit).
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 88 of 348
17B-88V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF081
CONTINUED 3
Disconnect the battery.
Check the condition of the connector for the engine management computer (see Wiring Diagram Technical Note
for NEW TWINGO, E33, CLIO III, or MODUS, component code 120).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the "Universal bornier" to check the insulation and continuity of the following connection:
●3BB between components 120 and 371.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for earth on connection 3BB of the fuel vapour absorber bleed solenoid valve when running command
AC017 Canister bleed solenoid valve.
If the fault is still present, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 97 of 348
17B-97V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF084
PRESENT
OR
STOREDACTUATOR RELAY CONTROL CIRCUITCO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Abnormal voltage
2.DEF: EOBD
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running.
Special notes:
This relay supplies the following actuators: the injectors, the throttle valve control, the
oxygen sensor heaters, the fuel vapour absorber bleed solenoid valve and connection
3FB of the injection computer.
CO/CC.1: No actuator supply: same effect as running out of fuel. The vehicle stalls and
will not start again.
CC.0: The actuators are supplied constantly: high electrical consumption when
stationary.
Intermittent CO: Intermittent relay cut-off: bucking when driving.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III, or
MODUS.
Check the condition of the engine management computer connector (component code 120).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
For NEW TWINGO or E33:
Check the condition of the injection locking relay connector (component code 238).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the universal bornier to check the insulation and continuity of the following connections:
●3AA between components 238 and 120,
●3FB between components 238 and 193, 194, 195, 196, 1076, 242, 887, 371.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
SIM32_V44_DF084/SIM32_V4C_DF084/SIM32_V50_DF084/SIM32_V54_DF084
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 102 of 348
17B-102V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF089
CONTINUED
If the fault is still present, carry out the following checks:
The inlet line must be perfectly sealed, from the throttle valve to the cylinder head.
Check:
–the condition of the air filter,
–that the air inlet circuit is not blocked,
–the sealing between the throttle valve and inlet manifold,
–the manifold pressure sensor sealing,
–the fuel vapour absorber bleed, which must not be jammed open,
–the fuel vapour absorber bleed system sealing,
–the brake servo system sealing,
–the cylinder head oil vapour recovery system sealing,
–the sealing between the inlet manifold and cylinder head,
–the exhaust pipe sealing between the cylinder head and catalytic converter.
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 103 of 348
17B-103V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF091
PRESENT
OR
STOREDVEHICLE SPEED SIGNAL
1.DEF: Missing or invalid multiplex signals (fault with computer issuing the signal or
with multiplex line connection)
2.DEF: EOBD
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the ignition is switched on or with the engine running.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, carry out fault finding on the ABS computer (see 38C, Anti-lock braking system).
Check the condition of the engine management computer connector (component code 120).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
If the fault is still present, contact the Techline.
SIM32_V44_DF091/SIM32_V4C_DF091/SIM32_V50_DF091/SIM32_V54_DF091
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 145 of 348
17B-145V7 MR-413-X44-17B000$133.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF404
PRESENT
OR
STOREDAUTOMATIC TRANSMISSION OR SEQUENTIAL GEARBOX
CAN
CONNECTION
1.DEF: Incorrect gear
2.DEF: Incorrect torque signal from automatic gearbox computer
3.DEF: Multiplex signals absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the ignition is switched on or with the engine running.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, run fault finding on the Sequential gearbox (see 21B, Sequential gearbox).
If the fault is still present, contact the Techline.
SIM32_V44_DF404/SIM32_V4C_DF404/SIM32_V50_DF404/SIM32_V54_DF404
AFTER REPAIREnsure that all the faults have been dealt with.
Clear the stored faults. Do not clear the programming.
To check that the system has been properly repaired:
–there must be no further electrical faults,
–programming has been carried out,
the engine must be warm (minimum 75˚C), and idling, with all electrical consumers
running for 15 minutes.
Page 148 of 348
17B-148V7 MR-413-X44-17B000$133.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF455
PRESENT
OR
STOREDLOW FUEL LEVEL SIGNAL
1.DEF: Multiplex signals absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault).
2.DEF: EOBD
NOTESConditions for applying the fault finding procedure to stored faults
The fault is declared present when the ignition is switched on.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Disconnect the battery and the fuel sender.
Check the condition of the fuel pump and sender unit connector (component code 199, for NEW TWINGO or
component code 833 (for E33, CLIO III or MODUS).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the universal bornier to check the insulation and continuity of the following connections:
●AP41 between components 199 and 247 (for NEW TWINGO),
●41B between components 199 and 247 (for NEW TWINGO),
●41A between components 833 and 247 (for E33, CLIO III or MODUS),
●41B between components 833 and 247 (for E33, CLIO III or MODUS).
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, test the multiplex network (see 88B, Multiplex).
If the fault is not resolved, run fault finding on the Instrument panel (see 83A, Instrument panel).
If the fault is still present, contact the Techline.
SIM32_V44_DF455/SIM32_V4C_DF455/SIM32_V50_DF455/SIM32_V54_DF455
AFTER REPAIRFollow the instructions to confirm repair:
–If the fault is present, continue to deal with the fault.
–If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.