fuel RENAULT TWINGO RS 2009 2.G Electrical Equipment - Petrol Injection Owner's Guide
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: TWINGO RS, Model: RENAULT TWINGO RS 2009 2.GPages: 348
Page 88 of 348
17B-88V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF081
CONTINUED 3
Disconnect the battery.
Check the condition of the connector for the engine management computer (see Wiring Diagram Technical Note
for NEW TWINGO, E33, CLIO III, or MODUS, component code 120).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the "Universal bornier" to check the insulation and continuity of the following connection:
●3BB between components 120 and 371.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for earth on connection 3BB of the fuel vapour absorber bleed solenoid valve when running command
AC017 Canister bleed solenoid valve.
If the fault is still present, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 97 of 348
17B-97V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF084
PRESENT
OR
STOREDACTUATOR RELAY CONTROL CIRCUITCO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Abnormal voltage
2.DEF: EOBD
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running.
Special notes:
This relay supplies the following actuators: the injectors, the throttle valve control, the
oxygen sensor heaters, the fuel vapour absorber bleed solenoid valve and connection
3FB of the injection computer.
CO/CC.1: No actuator supply: same effect as running out of fuel. The vehicle stalls and
will not start again.
CC.0: The actuators are supplied constantly: high electrical consumption when
stationary.
Intermittent CO: Intermittent relay cut-off: bucking when driving.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III, or
MODUS.
Check the condition of the engine management computer connector (component code 120).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
For NEW TWINGO or E33:
Check the condition of the injection locking relay connector (component code 238).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the universal bornier to check the insulation and continuity of the following connections:
●3AA between components 238 and 120,
●3FB between components 238 and 193, 194, 195, 196, 1076, 242, 887, 371.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
SIM32_V44_DF084/SIM32_V4C_DF084/SIM32_V50_DF084/SIM32_V54_DF084
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 99 of 348
17B-99V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF085
PRESENT
OR
STOREDFUEL PUMP RELAY CONTROL CIRCUITCO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: EOBD
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present with the ignition on or the engine running, or during
command AC015 Fuel pump relay.
Special notes:
CO/CC.1: The effect of the fault is the same as running out of fuel. The vehicle stalls
and cannot be restarted.
CC.0: There is danger of fire in the event of petrol leaking during an accident.
Intermittent CO: Risk of intermittent ignition cut-off and draining the battery.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Check the condition of the engine management computer connector (component code 120).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
For NEW TWINGO or E33:
Check the condition of the fuel pump relay (component code 236).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the "universal bornier" to check the insulation and continuity of the following connection:
●3AC between components 236 and 120,
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for an earth during activation of command AC015 Fuel pump relay.
SIM32_V44_DF085/SIM32_V4C_DF085/SIM32_V50_DF085/SIM32_V54_DF085
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 100 of 348
17B-100V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF085
CONTINUED
With the ignition on, if the + 12 V is still not present on the fuel pump relay connector, there is a fault in the engine
fuse and relay box.
Run fault finding on the engine fuse and relay box to check the continuity of the following connection:
●BP17 between components 120 and 597,
●BP17 between components 1033 and 597.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, check the battery and run fault finding on the charging circuit (see Technical Note 6014A,
Checking the charging circuit).
For CLIO III or MODUS:
Check the condition of the Protection and Switching Unit (see Wiring Diagram Technical Note, CLIO III or
MODUS, component code 1337).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the "universal bornier" to check the insulation and continuity of the following connection:
●3AC between components 1337 and 120.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for an earth during activation of command AC015 Fuel pump relay.
If the fault is still present, there is a fault in the Protection and Switching Unit (the fuel pump relay is in the Protection
and Switching Unit and cannot be dismantled).
Run fault finding on the UPC, component code 1337 (see 87G, Engine compartment connection unit).
If the fault is still present, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 102 of 348
17B-102V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF089
CONTINUED
If the fault is still present, carry out the following checks:
The inlet line must be perfectly sealed, from the throttle valve to the cylinder head.
Check:
–the condition of the air filter,
–that the air inlet circuit is not blocked,
–the sealing between the throttle valve and inlet manifold,
–the manifold pressure sensor sealing,
–the fuel vapour absorber bleed, which must not be jammed open,
–the fuel vapour absorber bleed system sealing,
–the brake servo system sealing,
–the cylinder head oil vapour recovery system sealing,
–the sealing between the inlet manifold and cylinder head,
–the exhaust pipe sealing between the cylinder head and catalytic converter.
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 116 of 348
17B-116V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF109
PRESENT
OR
STOREDLOW FUEL LEVEL MISFIRING
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: EOBD
NOTESPriorities when dealing with a number of faults:
Firstly, deal with the following faults:
–DF085 Fuel pump relay control circuit,
–DF026 Cylinder 1 injector circuit
–DF027 Cylinder 2 injector circuit, DF028 Cylinder 3 injector circuit,
–DF029 Cylinder 4 injector circuit,
–DF059 Misfiring on cylinder 1,
–DF060 Misfiring on cylinder 2,
–DF061 Misfiring on cylinder 3,
–DF062 Misfiring on cylinder 4,
–DF436 Combustion misfiring detection,
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present when the engine is running.
Special notes:
1.DEF: As soon as the fault is detected, the injection is cut for the faulty cylinder(s) to
limit the rise in temperature inside the catalytic converter. The OBD warning light
flashes for as long as the fault is present.
2.DEF: The OBD warning light is continuously lit.
Check:
–the level of fuel in the tank,
–the conformity and the grade of the fuel, apply test 1 Petrol conformity check,
–the fuel filter,
–the fuel pump,
–the fuel lines,
–the fuel pressure.
If there is no present or stored misfiring fault, the misfiring was caused by the low fuel level.
SIM32_V44_DF109/SIM32_V4C_DF109/SIM32_V50_DF109/SIM32_V54_DF109
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 117 of 348
17B-117V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C
and 54
DF119
PRESENT
OR
STOREDCAMSHAFT SENSOR SIGNAL1.DEF: Camshaft tooth event
2.DEF: Tooth lost
3.DEF: Measurement of the offset outside permitted range of values
4.DEF: EOBD
5.DEF: Programming the stops
6.DEF: Programming the initial stops
NOTESPriorities when dealing with a number of faults:
Deal first with fault DF084 Actuator relay control circuit or DF046 Battery voltage
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present when the engine is running.
Special notes:
Engine operation without camshaft dephaser: deterioration in fuel consumption
performance.
Use Wiring Diagram Technical Note for CLIO III or MODUS.
Check the condition of the camshaft position sensor connector and its wiring (component code 1265).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
If the fault is still present, check, with the ignition on, for +12 V on connection 3FB of the camshaft sensor,
component code 1265.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
SIM32_V44_DF119/SIM32_V4C_DF119/SIM32_V54_DF119
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 135 of 348
17B-135V7 MR-413-X44-17B000$133.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF330
CONTINUEDPINKING SENSOR CIRCUIT1.DEF: Abnormal voltage
2.DEF: EOBD
Use the universal bornier to check the insulation and continuity of the following connections:
●3S between components 120 and 146,
●3DQ between components 120 and 146.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the conformity of the fuel in the tank, apply test 1 Petrol conformity check.
Check that the spark plugs are correct.
Repair if necessary.
AFTER REPAIRFollow the instructions to confirm repair:
–If the fault is present, continue to deal with the fault.
–If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 136 of 348
17B-136V7 MR-413-X44-17B000$133.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF361
PRESENT
OR
STOREDIGNITION COIL 1 - 4 CIRCUIT
CC.1: Short circuit to + 12 V
CO.0: Open circuit or short circuit to earth
1.DEF: EOBD
NOTESPriorities when dealing with a number of faults:
Firstly, deal with the following faults:
–DF046 Battery voltage,
–DF084 Actuator relay control circuit,
–DF085 Fuel pump relay control circuit,
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the starter has been in operation for 10 seconds or
after the engine has been running for 10 seconds.
Special notes:
If a fault is present, injectors 1 and 4 are switched off after 60 seconds at
600 rpm or 6 seconds at 6000 rpm, until the ignition is switched off.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Disconnect the quadruple ignition coil module connector and check the cleanliness and condition of its connections
(component code 108) and of the engine management computer connector (component code 120).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the universal bornier to check the insulation and continuity of the following connection:
●3CV between components 120 and 108.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
With the ignition on, check for + 12 V on connection 3N of the ignition quadruple coil module.
If there is no + 12 V:
Disconnect the battery and apply the following steps, depending on the vehicle.
SIM32_V44_DF361/SIM32_V4C_DF361/SIM32_V50_DF361/SIM32_V54_DF361
AFTER REPAIRFollow the instructions to confirm repair:
–If the fault is present, continue to deal with the fault.
–If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.
Page 137 of 348
17B-137V7 MR-413-X44-17B000$133.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF361
CONTINUED 1
For NEW TWINGO or E33:
–Check the condition of the fuel pump relay connector (component code 236).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the "universal bornier" to check the insulation and continuity of the following connection:
●3N between components 236 and 108,
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Carry out a fault finding procedure on the engine fuse and relay box to check the continuity of the following
connection:
●BP17 between components 120 and 597,
●BP17 between components 238 and 597.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, check the battery and run fault finding on the charging circuit (see Technical Note 6014A,
Checking the charging circuit).
–Clean the battery terminals and all connections to + and to Earth.
–Check the battery voltage.
–Check the charging circuit.
AFTER REPAIRFollow the instructions to confirm repair:
–If the fault is present, continue to deal with the fault.
–If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.