engine RENAULT TWINGO RS 2009 2.G Heating And Air Conditioning - Manual Air Conditioning Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: TWINGO RS, Model: RENAULT TWINGO RS 2009 2.GPages: 63
Page 7 of 63

62C-7
MR-413-X44-62C000$182_eng.mif
V1
62C
MANUAL AIR CONDITIONING
Fault finding - List and location of components
System (cold loop, hot loop and components)
1Air conditioning unit
2Heater matrix
3Expansion valve and evaporator
4Coolant circuit
5Cold loop
6Condenser and radiator
7Compressor
●COLD LOOP COMPONENTS:
–Compressor: This is located at the bottom on the left-hand side, next to the radiator in the engine compartment.
–Condenser: This is located between the radiator and the cooling fan assembly.
–Dehydrator reservoir: This is located on the left-hand side of the condenser outlet.
–Heating and air conditioning unit: This is located under the dashboard.
–Thermostatic expansion valve: This is located to the left of the heating and air conditioning unit on the
bulkhead.
–Evaporator: This is located to the right of the thermostatic expansion valve in the heating and air conditioning
unit.
–High pressure pipe: this pipe connects the compressor, condenser, dehydrator reservoir, and expansion valve
inlet in series (it is located in the engine compartment on the left-hand side).
–Low pressure pipe: this pipe connects the expansion valve, buffering capacity, evaporator, and compressor
inlet in series (it is located in the engine compartment on the left-hand side).
MR-413-X44-62C000$182_eng.mif
Page 11 of 63

62C-11
MR-413-X44-62C000$273_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Role of components62C
–High and low pressure pipes:
●The High Pressure and Low Pressure pipes are composed of rigid aluminium pipes and flexible pipes that
enable engine-related movements to be absorbed.
●Two filler valves (High Pressure and Low Pressure) can be accessed in order to fill (or drain) the refrigerant loop.
●The connections must be checked in the event of a refrigerant fluid leak.
1Buffering capacity
2Expansion valve outlet
3Expansion valve inlet
4High pressure filler valve
5Low pressure filler valve
6Condenser inlet
7Condenser outlet
8Pressure sensor
9Compressor inlet
10 Compressor outlet
Figure 6: Cold loop pipes
●HEATING COMPONENTS
–Heater matrix:
The external air entering the heating and air conditioning device (HVAC) is heated by the heater matrix.
Page 12 of 63

62C-12
MR-413-X44-62C000$273_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Role of components62C
–Passenger compartment heating resistors (depending on the equipment level):
The passenger compartment heating resistors (RCH) are electrical heating devices in the air conditioning unit. This
system is an additional heating system which operates when the engine is cold (when starting).
ACTUATORS
–Air distribution flap:
This flap enables the air flowing into the passenger compartment to be directed.
–Air mixing flap:
This flap mixes the air in order to meet the temperature requirements of the occupants.
–Recirculation flap:
This flap prevents the entry of exterior air. In this case, the passenger compartment is isolated from the exterior and
air is blown in the passenger compartment in a closed circuit.
These three flaps are controlled by a cable.
●OTHERS
–Passenger compartment blower unit:
The passenger compartment blower unit is controlled by the Resistive Blower Dimmer Module (MVPR).
Page 17 of 63

62C-17
MR-413-X44-62C000$455_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Function62C
Exchanges between the two air conditioning computers (manual air conditioning)
–air conditioning request
–switch on heated rear screen request (+ electric door mirrors)
–passenger compartment ventilation signal
MANUAL AIR
CONDITIONING
CONTROL PANELUCH
–Heated rear screen warning light lit
–Air conditioning warning light lit
–Air conditioning request 2
UCHINJECTION
COMPUTER
–Air conditioning authorisation
–Engine status signal
Page 19 of 63

62C-19
MR-413-X44-62C000$455_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Function62C
Vehicle
multiplex
network
Summary diagram of components controlled or managed by the UCH:
Summary diagram of components controlled or managed by the injection computer Rear screen de-icing and
rear-view mirror de-icer
(depending on version)External temperature
sensor
(depending on
version)
Actuator control Sensor management
UCH
Air conditioning request
managementHeated rear screen control
management
Relay No. 1 for
the Passenger
Compartment
Heating
ResistorsRelay No. 2 for
the Passenger
Compartment
Heating
ResistorsAir conditioning
compressorEngine cooling
fan assemblyEngine
coolant
temperature
sensorRefrigerant
fluid
pressure
sensor
Actuator control Sensor management
Engine injection computer
Management of the cold loop (refrigerant pressure, engine cooling fan activation request,
compressor activation authorisation, etc.)
Key:
Wire connections =
Multiplex connections =
Page 22 of 63

62C-22
MR-413-X44-62C000$637_eng.mif
V1
62C
MANUAL AIR CONDITIONING
Fault finding - Conformity check
SUB-FUNCTION: COLD LOOP
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped, ignition on, AIR CONDITIONING
SWITCHED OFF (Passenger compartment blower unit switched off and air
conditioning compressor not activated).
Note:
Read the parameters when the vehicle is cold (in the morning) to check the conformity
of the temperature parameters (without thermometer). The temperatures should be
approximately equal (interior, exterior and engine coolant).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
UCH (see 87B,
Passenger
compartment
connection unit)PR002: Exterior
temperature
(depending on
the version)X = exterior temperature
± 5 ˚C (invalid value:
215 ˚C)In the event of a fault, see the
interpretation of this
parameter.
ET030: Air conditioning
request 2INACTIVE In the event of a fault, refer to the
interpretation of this status.
Note:
This status represents the
request from the UCH to the
injection computer to activate the
compressor.
ET015: Passenger
compartment
blowerINACTIVE
(according to test
conditions: see Notes).In the event of a fault, refer to the
interpretation of this status.
PR025: Engine speed0 rpmIn the event of a fault, see the
interpretation of this
parameter.
ET142: Engine
operating phaseSTOPPEDIn the event of a fault, refer to the
interpretation of this status.
MR-413-X44-62C000$637_eng.mif
Page 23 of 63

62C-23
MR-413-X44-62C000$637_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Conformity check62C
COLD LOOP SUB-SYSTEM (CONTINUED 1)
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped, ignition on, AIR CONDITIONING
SWITCHED OFF (Passenger compartment blower unit switched off and air
conditioning compressor not activated).
Note:
Read the parameters when the vehicle is cold (in the morning) to check the conformity
of the temperature parameters (without thermometer). The temperatures should be
approximately equal (interior, exterior and engine coolant).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
Injection
(see 13B, Diesel
injection or 17B,
Petrol injection)ET079:Air conditioning
presentYES
(automatic injection
computer configuration)If the status displays NO, refer
to the interpretation of this
status.
ET088:Compressor
actuation
requestINACTIVEIf the status displays ACTIVE,
refer to the interpretation of this
status.
ET004:Air conditioning
authorisationNO
(no authorisation with
engine stopped)In the event of a fault, refer to the
interpretation of this status.
PR037:Refrigerant
pressure 1 bar < X < 15 barIn the event of a fault, see the
interpretation of this
parameter.
PR055:Engine speed0 rpmIn the event of a fault, see the
interpretation of this
parameter.
ET023:Fast idle speed
requestABSENTIn the event of a fault, refer to the
interpretation of this status.
Page 24 of 63

62C-24
MR-413-X44-62C000$637_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Conformity check62C
SUB-FUNCTION: COLD LOOP (CONTINUED 2)
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped, ignition on, AIR CONDITIONING
SWITCHED OFF (Passenger compartment blower unit switched off and air
conditioning compressor not activated).
Note:
Read the parameters when the vehicle is cold (in the morning) to check the conformity
of the temperature parameters (without thermometer). The temperatures should be
approximately equal (interior, exterior and engine coolant).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
Injection
(continued)PR064:Coolant
temperatureX = engine coolant
temperatureIn the event of a fault, see the
interpretation of this
parameter.
PR089:Vehicle speed0 mphIn the event of a fault, see the
interpretation of this
parameter.
PR125:Power absorbed
by the air
conditioning
compressor0 W (ambient
temperature 23 ˚C)In the event of a fault, see the
interpretation of this
parameter.
ET022:Low speed fan
assembly
requestINACTIVEIn the event of a fault, refer to the
interpretation of this status.
ET021:High speed fan
assembly
requestINACTIVEIn the event of a fault, refer to the
interpretation of this status.
Page 25 of 63

62C-25
MR-413-X44-62C000$637_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Conformity check62C
SUB-FUNCTION: HEATING
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped, ignition on, AIR CONDITIONING
SWITCHED OFF (Passenger compartment blower unit switched off and air
conditioning compressor not activated).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
UCH (see 87B,
Passenger
compartment
connection unit)ET015:Passenger
compartment
blowerINACTIVE
(according to test
conditions: see Notes).In the event of a fault, refer to the
interpretation of this status.
PR001:Battery voltage10.5 V < X <14.4 VIf there is a fault, refer to the
interpretation of this
parameter If the fault is still
present, carry out fault finding on
the charging circuit (see MR 411
Mechanical, 16A, Starting -
Charging).
PR002:Exterior
temperature
(depending on
the version)X = exterior
temperature ±± ± ±
5 ˚C
(invalid value: 215 ˚C).If there is a fault, refer to the
interpretation of this
parameter
PR024:Engine coolant
temperatureX = engine coolant
temperature in ˚C.If there is a fault, refer to the
interpretation of this
parameter
ET239:Ignition switch
position+ after ignition feedIn the event of a fault, refer to the
interpretation of this status.
PR025:Engine speed0 rpmIf there is a fault, refer to the
interpretation of this
parameter
Page 26 of 63

62C-26
MR-413-X44-62C000$637_eng.mif
V1
MANUAL AIR CONDITIONING
Fault finding - Conformity check62C
SUB-FUNCTION: HEATING (CONTINUED)
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: engine stopped, ignition on, AIR CONDITIONING
SWITCHED OFF (Passenger compartment blower unit switched off and air
conditioning compressor not activated).
ComputerParameter or Status
checked or ActionDisplay and Notes Fault finding
Injection (see 13B,
Diesel injection or
17B, Petrol
injection)PR064:Coolant
temperatureX = engine coolant
temperatureIf there is a fault, refer to the
interpretation of this
parameter
ET111:RCH number setNO
Note: Depending on the
requirements of the
injection system (power
requirement, torque
reduction, etc.), the
injection computer sets
the controlled
passenger compartment
heating resistor stage
number (no more, no
less)In the event of a fault, refer to the
interpretation of this status.
ET112:Passenger
compartment
heating resistor
cut-offYESIn the event of a fault, refer to the
interpretation of this status.