Page 83 of 88 Report No. : 60404490 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC62368_1 C
5.6.4.2.1 France
After the indent for pluggable equipment type A ,
the following is added:
– in certain cases, the protective current rating of
the circuit supplied from the mai ns is taken as 20 A
instead of 16 A. N/A
5.6.5.1 To the second paragraph the following is added:
The range of conductor sizes of flexible cords to be
accepted by terminals for equipment with a rated
current over 10 A and up to and including 13 A is:
1,2 5 mm 2
to 1,5 mm 2
in cross - sectional area. N/A
5.6.8 Norway
To the end of the subclause the following is added:
Equipment connected with an earthed mains plug is
classified as class I equipment . See the Norway
marking requirement in 4.1.15. The symbol IE C
60417 - 6092, as specified in F.3.6.2, is accepted . N/A
5.7.6 Denmark
To the end of the subclause the following is added:
The installation instruction shall be affixed to the
equipment if the protective conductor current
exceeds the limits of 3,5 mA a. c. or 10 mA d.c. N/A
5.7.6.2 Denmark
To the end of the subclause the following is added:
The warning (marking safeguard) for high touch
current is required if the touch current or the
protective current exceed the limits of 3,5 mA . N/A
5.7.7.1 Norway and Sweden
To the end of the subclause the following is added:
The screen of the television distribution system is
normally not earthed at the entrance of the building
and there is normally no equipotential bonding
system within the building.
Therefore t he protective earthing of the building
installation needs to be isolated from the screen of a
cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic iso lator, which
may be provided by a retailer, for example.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what country
the equipment is intended to be used in:
“Apparatus connected to the protective earthing of N/A