Page  17   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  5.2.2.2   Steady - state voltage and current limits   ....................   :   (See appended table 5.2)   P  
5.2.2.3   Capacitance limits   ................................ .....................   :     N/A  
5.2.2.4   Single pulse limits   ................................ .....................   :   No such single pulse wi th the  
e quipment   N/A  
5.2.2.5   Limits for repetitive pulses   ................................ ........   :   No such repetitive pulses with 
the  e quipment   N/A  
5.2.2.6   Ringing signals    No Ringing signals   N/A  
5.2.2.7   Audio signals      P  
5.3   Protection against electrical energy sources  
N/A  
5.3.1   General R equirements for accessible parts to 
ordinary, instructed and skilled persons   Only ES1   N/A  
5.3.1 a)   Accessible ES1/ES2 derived from ES2/ES3 circuits     N/A  
5.3.1 b)   Skilled persons   not unintentional contact ES3 bare 
conductors     N/A  
5.3.2.1   Accessibility to   electrical energy sources and 
safeguards      N/A  
  Accessibility to outdoor equipment bare parts     N/A  
5.3.2.2   Contact requirements     N/A  
  Test with test probe from Annex V     -  
5.3.2.2 a)   Air gap  –   electric strength test potential (V)   .............   :     N/A  
5.3.2.2 b)   Air   gap  –   distance (mm)    ................................ ...........   :     N/A  
5.3.2.3   Compliance     N/A  
5.3.2.4   Terminals for connecting stripped wire      N/A  
5.4   Insulation materials and requirements  
N/A  
5.4.1.2   Properties of insulating material      N/A  
5.4.1.3   Material is non - hygroscopic     N/A  
5.4.1.4   M aximum operating temperature for insulating 
materials   ................................ ................................ ....   :     N/A  
5.4.1.5   Pollution degrees   ................................ ......................   :     N/A  
5.4.1.5.2   Test for pollution degree 1 environment and for an 
insulating compound     N/A  
5.4.1.5.3   Thermal cycling test     N/A  
5.4.1.6   Insulation in transformers w ith varying dimensions     N/A  
5.4.1.7   Insulation in circuits generating starting pulses     N/A  
5.4.1.8   Determination of working voltage   .............................   :     N/A   
Page 28 of 406

   
 
Page  23   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  6.4.3   Redu ction of the likelihood of ignition under single 
fault conditions in PS2 and PS3 circuits     N/A  
6.4.3.1    Supplementary safeguards     N/A  
6.4.3.2   Single Fault Conditions   ................................ ..........   :     N/A  
  Special conditions for temperature limited by fuse     N/A  
6.4.4   Control of fire  spread in PS1 circuits     P  
6.4.5   Control of fire spread in PS2 circuits     P  
6.4.5.2   Supplementary safeguards   For conductor and devices are 
mounted   on  printed board 
made of  Min. V - 1.  
Other components in PS2   are  
mounted on printed board 
made of   Min.   V - 1   and  PVC 
wire used .  
Not ignite during single fault 
condition .   P  
6.4.6   Control of fire spread in PS3 circuits   Provided  Metallic   enclosure   P  
6.4.7   Separation of combustible materials from a PIS     P  
6.4.7.2   Separation by distance     N/A  
6.4.7.3   Separation by a f ire barrier     P  
6.4.8   Fire enclosures and fire barriers     P  
6.4.8.2   Fire enclosure and fire barrier material properties     P  
6.4.8.2.1   Requirements for a fire barrier   V - 0 class material or metal, 
Printed board made of V - 0   P  
6.4.8.2.2   Requirem ents for a fire enclosure   Metallic   enclosure provided   P  
6.4.8.3   Constructional requirements for a fire enclosure 
and a fire barrier     P  
6.4.8.3.1   Fire enclosure and fire barrier openings     P  
6.4.8.3.2   Fire barrier dimensions     P  
6.4.8.3.3   Top openings and   properties   E quipment for building - in ,  
e valuation shall be considered 
in the end product   N/A  
  Openings dimensions (mm)   ................................ ...   :     N/A  
6.4.8.3.4   Bottom openings and properties   E quipment for building - in ,  
e valuation shall be considered 
in the end product   N/A  
  Open ings dimensions (mm)   ................................ ...   :     N/A  
  Flammability tests for the bottom of a fire enclosure     N/A   
Page 30 of 406

   
 
Page  25   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  8.5.1   Fingers, jewellery, clothing, hair, etc., contact with 
MS2 or MS3 parts     N/A  
  MS2 or MS3 part required to be accessible for the 
function of t he equipment      N/A  
  Moving MS3 parts only accessible to skilled person     N/A  
8.5.2   Instructional safeguard ................................ ..............   :     N/A  
8.5.4   Special categories of equipment containing moving 
parts     N/A  
8.5.4.1   General     N/A  
8.5.4.2   Equipment containing work cells with MS3 p arts     N/A  
8.5.4.2.1   Protection of persons in the work cell     N/A  
8.5.4.2.2   Access protection override     N/A  
8.5.4.2.2.1   Override system    
N/A  
8.5.4.2.2.2   Visual indicator    
N/A  
8.5.4.2.3   Emergency stop system    
N/A  
  Maximum stopping distance from the poin t of 
activation (m)   ................................ .............................   :     N/A  
  Space between end point and nearest fixed 
mechanical part (mm)   ................................ ...............   :     N/A  
8.5.4.2.4   Endurance requirements     N/A  
  Mechanical system subjected to 100 000 cycles of 
operation     N/A  
  -   Mechanical function check and visual inspection      N/A  
  -   Cable assembly   ................................ ......................   :     N/A  
8.5.4.3   Equipment having electromechanical device for 
destruction of media      N/A  
8.5.4.3.1   Equipment safeguards     N/A  
8.5.4.3.2   Instructional safeguards against moving parts   ........   :     N/A  
8.5.4.3.3   Disconnection from the supply     N/A  
8.5.4.3.4   Cut type and test force (N)   ................................ ........   :     N/A  
8.5.4.3.5   Compliance     N/A  
8.5.5   High pressure lamps    No High pressure lamps   N/A  
  Explosion test   ................................ ............................   :     N/A  
8.5.5.3   Glass particles dimensions (mm)   .............................   :     N/A  
8.6   Stability of equipment  
N/A   
Page 47 of 406

   
 
Page  42   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  O   MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES  
N/A  
  Value of  X   (mm)   ................................ .....................   :  
 
  
P   SAFEGUARDS AGAINST CONDUCTIVE OBJECTS  
N/A  
P.1   General  
  N/A  
P.2   Safeguards against entry or consequences of entry of a foreign object  
N/A  
P.2.1   General   No  opening in accessible 
enclosure   N/A  
P.2.2   Safeguards against entry of  a  foreign object     N/A  
  Location and Dimensions (mm)    ............................   :    
  
P.2.3   Safeguards against the consequences of entry of a 
foreign object     N/A  
P.2.3.1   Safeguard requirements     N/A  
  The ES3 an d PS3 keep - out volume in Figure P.3 
not applicable to transportable equipment      N/A  
  Transportable equipment with metalized plastic 
parts   ................................ ................................ .......   :     N/A  
P.2.3.2   Consequence of entry test   ................................ ....   :     N/A  
P.3   Safeguards against spillage of internal liquids  
N/A  
P.3.1   Gene ral   No internal liquids   N/A  
P.3.2   Determination of spillage consequences      N/A  
P.3.3   Spillage safeguards     N/A  
P.3.4   Compliance     N/A  
P.4   Metallized coatings and adhesives securing parts  
N/A  
P.4.1   General   No meta l lized coating  and  
adhesive conducted par ts   N/A  
P.4.2   Tests     N/A  
  Conditioning, T
C   (°C)   ................................ .............   :    
  
  Duration (weeks)   ................................ ...................   :    
  
Q   CIRCUITS INTENDED FOR INTERCONNECTION WITH BUILDING WIRING  
P  
Q.1   Limited power sources  
  P  
Q.1.1   Requirements     P  
  a) Inherently limited output     N/A  
  b) Impedance limited ou tput     N/A  
  c) Regulating network limited output     P   
Page 63 of 406

   
 
Page  58   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
4.1.2   TABLE: Critical components information  
P  
Object / part No.   Manufacturer/  
trademark   Type / model   Technical data   S tandard   Mark(s) of 
conformity 1)
 
Plastic 
Enclosure   LG CHEM LTD   LUPOY GN -
5007F(#)   V - 0   UL 94   UL   ( E67171 )  
Alternate   Interchangeable   Interchangeable   Min.  HB   UL 94   UL  
-   Description:   Interchangeability based on specified ratings  
Metal Enclosure   Interchangeabl e   Interchangeable   AL or EGI(SECC)  
or GI(SGCC) or   
NI or ALDC or   
MG or SUS or   
STS or NSP or   
STEEL, Min. 0.4   
thickness   IEC 62368 - 1   Tested in 
equipment    
-   Description:   Interchangeability based on specified ratings and dimensions  
PCB   ZHEJIANG 
HUABANG 
ELE CTRONICS 
CO LTD   H - 01   V - 0   UL 796   UL   ( E251053 )  
Alternate   HYUN WOO 
INDUSTRIAL 
CO LTD   3   V - 0   UL 796   UL (E131308)  
Alternate    Interchangeable   Interchangeable   Min. V - 1   UL 796   UL  
-   Description:   Interchangeability based on specified ratings  
LCD Panel   LG Display   Co., 
Ltd.   LA065WV1   6.5 inch ,    
( 800   x   480  )   IEC 62368 - 1   Tested in 
equipment    
Alternate   LG Display 
(Paju) Co., Ltd.   LA065WV3   6.5 inch ,    
( 800   x   480  )   IEC 60065   T Ü V - Rh  
(JPTUV -
080511)  
Alternate   Giantplus 
Technology Co., 
LTD.   GPM1696A0   6.5 inch ,    
( 800   x   480  )   IEC 60065   SGS F imko  
(FI - 37636)  
Mains connector 
material   KURARAY CO 
LTD   GN2330(#)   V - 0   UL 94   UL (E90350)  
Alternate   Interchangeable   Interchangeable   Min. V - 1   UL   94   UL  
-   Description:   Inte rchangeability based on specified ratings  
Fuse   ST   VN5E010MHTR -
E   13A Switch off   ISO/TS 
16949:2009   9136.STM2  
Supplementary information:  
1) 
Provided evidence ensures the agreed level of compliance. See OD - 2039.   
Page 126 of 406

   
 
Page  16   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  5.2.2.2   Steady - state voltage and current limits   ....................   :   (See appended table 5.2)   P  
5.2.2.3   Capacitance limits   ................................ .....................   :     N/A  
5.2.2.4   Single pulse limits   ................................ .....................   :   No such single pulse with the  
e quipment   N/A  
5.2.2.5   Limits for repetitiv e pulses   ................................ ........   :   No such repetitive pulses with 
the  e quipment   N/A  
5.2.2.6   Ringing signals    No Ringing signals   N/A  
5.2.2.7   Audio signals      P  
5.3   Protection against electrical energy sources  
N/A  
5.3.1   General Requirements for accessible parts to 
ordinary, inst ructed and skilled persons   Only ES1   N/A  
5.3.1 a)   Accessible ES1/ES2 derived from ES2/ES3 circuits     N/A  
5.3.1 b)   Skilled persons   not unintentional contact ES3 bare 
conductors     N/A  
5.3.2.1   Accessibility to electrical energy sources and 
safeguards      N/A  
  Accessibility to outdoor equipment bare parts     N/A  
5.3.2.2   Contact requirements     N/A  
  Test with test probe from Annex V     -  
5.3.2.2 a)   Air gap  –   electric strength test potential (V)   .............   :     N/A  
5.3.2.2 b)   Air gap  –   distance (mm)    ................................ ...........   :     N/A  
5.3.2.3   Compliance     N/A  
5.3.2.4   Terminals for connecting stripped wire      N/A  
5.4   Insulation materials and requirements  
N/A  
5.4.1.2   Properties of insulating material      N/A  
5.4.1.3   Material is non - hygroscopic     N/A  
5.4.1.4   Maximum operating temperature for insulating 
materi als   ................................ ................................ ....   :     N/A  
5.4.1.5   Pollution degrees   ................................ ......................   :     N/A  
5.4.1.5.2   Test for pollution degree 1 environment and for an 
insulating compound     N/A  
5.4.1.5.3   Thermal cycling test     N/A  
5.4.1.6   Insulation in transformers with varying dimensions     N/A  
5.4.1.7   Insulation in   circuits generating starting pulses     N/A  
5.4.1.8   Determination of working voltage   .............................   :     N/A   
Page 132 of 406

   
 
Page  22   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  6.4.3   Reduction of the likelihood of ignition under single 
f ault conditions in PS2 and PS3 circuits     N/A  
6.4.3.1    Supplementary safeguards     N/A  
6.4.3.2   Single Fault Conditions   ................................ ..........   :     N/A  
  Special conditions for temperature limited by fuse     N/A  
6.4.4   Control of fire spread in PS1 circuits     P  
6.4.5   Control of fire s pread in PS2 circuits     P  
6.4.5.2   Supplementary safeguards   For conductor and devices are 
mounted   on  printed board 
made of  Min. V - 1.  
Other components in PS2   are  
mounted on printed board 
made of   Min.   V - 1   and PVC 
wire used .  
Not ignite during single fault 
cond ition .   P  
6.4.6   Control of fire spread in PS3 circuits   Provided  Metallic   enclosure   P  
6.4.7   Separation of combustible materials from a PIS     P  
6.4.7.2   Separation by distance     N/A  
6.4.7.3   Separation by a fire barrier     P  
6.4.8   Fire enclosures and fire bar riers     P  
6.4.8.2   Fire enclosure and fire barrier material properties     P  
6.4.8.2.1   Requirements for a fire barrier   V - 0 class material or metal, 
Printed board made of V - 0   P  
6.4.8.2.2   Requirements for a fire enclosure   Metallic   enclosure provi ded   P  
6.4.8.3   Constructional requirements for a fire enclosure 
and a fire barrier     P  
6.4.8.3.1   Fire enclosure and fire barrier openings     P  
6.4.8.3.2   Fire barrier dimensions     P  
6.4.8.3.3   Top openings and properties   E quipment for building - in ,  
e valuation  shall be considered 
in the end product   N/A  
  Openings dimensions (mm)   ................................ ...   :     N/A  
6.4.8.3.4   Bottom openings and properties   E quipment for building - in ,  
e valuation shall be considered 
in the end product   N/A  
  Openings dimensions (mm)   ................................ ...   :     N/A  
  Flammability tests f or the bottom of a fire enclosure     N/A   
Page 133 of 406

   
 
Page  23   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
    Instructional Safeguard   ................................ .............   :     N/A  
6.4.8.3.5   Side openings and properties   E quipment for building - in ,  
e valuation shall be considered 
in the end product   N/A  
  Openings dimensions (mm)   ................................ ...   :     N/A  
6.4.8.3.6   Integrity of a fir e enclosure, condition met:  a), b) or 
c)   ................................ ................................ ............   :   Not such fire enclosure   N/A  
6.4.8.4   Separation of a PIS from a fire enclosure and a fire 
barrier distance (mm) or flammability rating   ..........   :   Not such fire enclosure   P  
6.4.9   Flammability of insulating liquid ...............................   :     N/A  
6.5   Internal and external wiring   
P  
6.5.1   General requirements      P  
6.5.2   Requirements for interconnection to building wiring
  ................................ ................................ ...............   :   No such interconnection to 
building wiring   N/A  
6.5.3   Internal wiring size (mm 2
) for socket - outlets   ..........   :     N/A  
6.6   Safeguards agai nst fire due to the connection to   additional   equipment  
P  
 
7   INJURY CAUSED BY HAZARDOUS SUBSTANCES  
N/A  
7.2   Reduction of exposure to hazardous substances   
N/A  
7.3    Ozone exposure  
N/A  
7.4   Use of personal safeguards   or personal protective equipment   (PPE)  
N /A  
  Personal safeguards and instructions   ...................   :    
  
7.5    Use of instructional safeguards and instructions  
N/A  
  Instructional safeguard (ISO 7010) ........................   :    
  
7.6   Batteries and their protection circuits  
N/A  
 
8   MECHANICALLY - CAUSED INJURY  
P  
8.2   Mechanical energy sou rce classifications  
P  
8.3   Safeguards against mechanical energy sources  
P  
8.4   Safeguards against parts with sharp edges and corners  
P  
8.4.1   Safeguards   All edges and corners are 
rounded or smoothed   P  
  Instructional Safeguard   ................................ .............   :   MS1   N/A  
8.4.2   Sharp edges  or corners      P  
8.5   Safeguards against moving parts  
N/A   
Page 134 of 406

   
 
Page  24   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  8.5.1   Fingers, jewellery, clothing, hair, etc., contact with 
MS2 or MS3 parts     N/A  
  MS2 or MS3 part required to be accessible for the 
function of the equipment      N/A  
  Moving MS3 parts only accessi ble to skilled person     N/A  
8.5.2   Instructional safeguard ................................ ..............   :     N/A  
8.5.4   Special categories of equipment containing moving 
parts     N/A  
8.5.4.1   General     N/A  
8.5.4.2   Equipment containing work cells with MS3 parts     N/A  
8.5.4.2.1   Protection of persons in the  work cell     N/A  
8.5.4.2.2   Access protection override     N/A  
8.5.4.2.2.1   Override system    
N/A  
8.5.4.2.2.2   Visual indicator    
N/A  
8.5.4.2.3   Emergency stop system    
N/A  
  Maximum stopping distance from the point of 
activation (m)   ................................ .............................   :     N/A  
  Space between end poi nt and nearest fixed 
mechanical part (mm)   ................................ ...............   :     N/A  
8.5.4.2.4   Endurance requirements     N/A  
  Mechanical system subjected to 100 000 cycles of 
operation     N/A  
  -   Mechanical function check and visual inspection      N/A  
  -   Cable assembly   ................................ ......................   :     N/A  
8.5.4.3   Equipment   having electromechanical device for 
destruction of media      N/A  
8.5.4.3.1   Equipment safeguards     N/A  
8.5.4.3.2   Instructional safeguards against moving parts   ........   :     N/A  
8.5.4.3.3   Disconnection from the supply     N/A  
8.5.4.3.4   Cut type and test force (N)   ................................ ........   :     N/A  
8.5.4.3.5   Compliance     N/A  
8.5.5   High pressure lamps    No High pressure lamps   N/A  
  Explosion test   ................................ ............................   :     N/A  
8.5.5.3   Glass particles dimensions (mm)   .............................   :     N/A  
8.6   Stability of equipment  
N/A   
Page 151 of 406

   
 
Page  41   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  O   MEASUREMENT OF CREEPAGE DIST ANCES AND CLEARANCES  
N/A  
  Value of  X   (mm)   ................................ .....................   :  
 
  
P   SAFEGUARDS AGAINST CONDUCTIVE OBJECTS  
N/A  
P.1   General  
  N/A  
P.2   Safeguards against entry or consequences of entry of a foreign object  
N/A  
P.2.1   General   No opening in accessible 
enclosure   N/A  
P.2.2   Safeg uards against entry of  a  foreign object     N/A  
  Location and Dimensions (mm)    ............................   :    
  
P.2.3   Safeguards against the consequences of entry of a 
foreign object     N/A  
P.2.3.1   Safeguard requirements     N/A  
  The ES3 and PS3 keep - out volume in Figure P.3 
not applicab le to transportable equipment      N/A  
  Transportable equipment with metalized plastic 
parts   ................................ ................................ .......   :     N/A  
P.2.3.2   Consequence of entry test   ................................ ....   :     N/A  
P.3   Safeguards against spillage of internal liquids  
N/A  
P.3.1   General   No internal liquids   N/A  
P.3.2   Determination   of spillage consequences      N/A  
P.3.3   Spillage safeguards     N/A  
P.3.4   Compliance     N/A  
P.4   Metallized coatings and adhesives securing parts  
N/A  
P.4.1   General   No meta l lized coating  and  
adhesive conducted parts   N/A  
P.4.2   Tests     N/A  
  Conditioning, T
C   (°C)   ................................ .............   :    
  
  Duration (weeks)   ................................ ...................   :    
  
Q   CIRCUITS INTENDED FOR INTERCONNECTION WITH BUILDING WIRING  
P  
Q.1   Limited power sources  
  P  
Q.1.1   Requirements     P  
  a) Inherently limited output     N/A  
  b) Impedance limited output     N/A  
  c) Regulating network limited output     P