Page  61   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 10.5.1   Add   the following after the first paragraph:  
For RS 1 compliance is checked by measurement 
under the following conditions:  
In addition to the normal operating condi tions, all 
controls adjustable from the outside by hand, by any 
object such as a tool or a coin, and those internal 
adjustments or presets which are not locked in a reliable 
manner, are adjusted so as to give maximum radiation 
whilst maintaining an intelli gible picture for 1 h, at the 
end of which the measurement is made.  
NOTE Z1  Soldered joints and paint lockings are examples of 
adequate locking.  
The dose - rate is determined by means of a  radiation 
monitor with an effective area of 10 cm², at any point 10  
cm from the outer surface of the apparatus.  
Moreover, the measurement shall be made under fault 
conditions causing an increase of the high - voltage, 
provided an intelligible picture is maintained for 1 h, at 
the end of which the measurement is made.  
For RS 1, the dose - rate shall not exceed 1 μSv/h taking 
account of the background level.  
NOTE Z2  These values appear in Directive 96/29/Euratom of 13 May 
1996.     N/A  
10.6.1   Add   the following paragraph to the end of the 
subclause:  
EN 71 - 1:2011, 4.20 and the relat ed tests methods and 
measurement distances apply.     N/A  
10.Z1   Add   the following new subclause after 10.6.5.  
10.Z1 Non - ionizing radiation from radio frequencies 
in the range 0 to 300 GHz  
The amount of non - ionizing radiation is regulated by 
European Council  Recommendation 1999/519/EC of 12 
July 1999 on the limitation of exposure of the general 
public to electromagnetic fields (0 Hz to 300 GHz).  
For intentional radiators, ICNIRP guidelines should be 
taken into account for Limiting Exposure to Time -
Varying Elec tric, Magnetic, and Electromagnetic Fields 
(up to 300 GHz). For hand - held and body - mounted 
devices, attention is drawn to EN 50360 and EN 50566     N/A  
G.7.1   Add   the following note:  
NOTE Z1  The harmonized code designations corresponding to the 
IEC cord type s are given in Annex ZD.     P   
Page 170 of 406

   
 
Page  60   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 10.5.1   Add   the following after the first paragraph:  
For RS 1 compliance is checked by measurement 
under the following conditions:  
In addition to the normal operating conditions, all 
controls adjustable from the outside by hand , by any 
object such as a tool or a coin, and those internal 
adjustments or presets which are not locked in a reliable 
manner, are adjusted so as to give maximum radiation 
whilst maintaining an intelligible picture for 1 h, at the 
end of which the measurem ent is made.  
NOTE Z1  Soldered joints and paint lockings are examples of 
adequate locking.  
The dose - rate is determined by means of a  radiation 
monitor with an effective area of 10 cm², at any point 10 
cm from the outer surface of the apparatus.  
Moreover,  the measurement shall be made under fault 
conditions causing an increase of the high - voltage, 
provided an intelligible picture is maintained for 1 h, at 
the end of which the measurement is made.  
For RS1, the do se - rate shall not exceed 1 μSv/h taking 
account of the background level.  
NOTE Z2  These values appear in Directive 96/29/Euratom of 13 May 
1996.     N/A  
10.6.1   Add   the following paragraph to the end of the 
subclause:  
EN 71 - 1:2011, 4.20 and the related tests  methods and 
measurement distances apply.     N/A  
10.Z1   Add   the following new subclause after 10.6.5.  
10.Z1 Non - ionizing radiation from radio frequencies 
in the range 0 to 300 GHz  
The amount of non - ionizing radiation is regulated by 
European Council Recommend ation 1999/519/EC of 12 
July 1999 on the limitation of exposure of the general 
public to electromagnetic fields (0 Hz to 300 GHz).  
For intentional radiators, ICNIRP guidelines should be 
taken into account for Limiting Exposure to Time -
Varying Electric, Mag netic, and Electromagnetic Fields 
(up to 300 GHz). For hand - held and body - mounted 
devices, attention is drawn to EN 50360 and EN 50566     N/A  
G.7.1   Add   the following note:  
NOTE Z1  The harmonized code designations corresponding to the 
IEC cord types are giv en in Annex ZD.     P   
Page 272 of 406

   
 
Page  59   of  88   Report No. :  60404489 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 10.5.1   Add   the following after the first paragraph:  
For RS 1 compliance is checked by measurement 
under the following conditions:  
In addition to the normal operating conditions, all 
controls adjustable from the outside by hand, by any 
object  such as a tool or a coin, and those internal 
adjustments or presets which are not locked in a reliable 
manner, are adjusted so as to give maximum radiation 
whilst maintaining an intelligible picture for 1 h, at the 
end of which the measurement is made.  
NOT E Z1  Soldered joints and paint lockings are examples of 
adequate locking.  
The dose - rate is determined by means of a  radiation 
monitor with an effective area of 10 cm², at any point 10 
cm from the outer surface of the apparatus.  
Moreover, the measurement  shall be made under fault 
conditions causing an increase of the high - voltage, 
provided an intelligible picture is maintained for 1 h, at 
the end of which the measurement is made.  
For RS1, the dose - rate sh all not exceed 1 μSv/h taking 
account of the background level.  
NOTE Z2  These values appear in Directive 96/29/Euratom of 13 May 
1996.     N/A  
10.6.1   Add   the following paragraph to the end of the 
subclause:  
EN 71 - 1:2011, 4.20 and the related tests methods an d 
measurement distances apply.     N/A  
10.Z1   Add   the following new subclause after 10.6.5.  
10.Z1 Non - ionizing radiation from radio frequencies 
in the range 0 to 300 GHz  
The amount of non - ionizing radiation is regulated by 
European Council Recommendation 1999 /519/EC of 12 
July 1999 on the limitation of exposure of the general 
public to electromagnetic fields (0 Hz to 300 GHz).  
For intentional radiators, ICNIRP guidelines should be 
taken into account for Limiting Exposure to Time -
Varying Electric, Magnetic, and   Electromagnetic Fields 
(up to 300 GHz). For hand - held and body - mounted 
devices, attention is drawn to EN 50360 and EN 50566     N/A  
G.7.1   Add   the following note:  
NOTE Z1  The harmonized code designations corresponding to the 
IEC cord types are given in Anne x ZD.     P   
Page 370 of 406

   
 
Page  59   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 10.5.1   Add   the following after the first paragraph:  
For RS 1 compliance is checked by measurement 
under the following conditions:  
In addition to the normal operating conditions, all 
controls adjustable from the outside by hand, by any 
objec t such as a tool or a coin, and those internal 
adjustments or presets which are not locked in a reliable 
manner, are adjusted so as to give maximum radiation 
whilst maintaining an intelligible picture for 1 h, at the 
end of which the measurement is made.  
N OTE Z1  Soldered joints and paint lockings are examples of 
adequate locking.  
The dose - rate is determined by means of a  radiation 
monitor with an effective area of 10 cm², at any point 10 
cm from the outer surface of the apparatus.  
Moreover, the measuremen t shall be made under fault 
conditions causing an increase of the high - voltage, 
provided an intelligible picture is maintained for 1 h, at 
the end of which the measurement is made.  
For RS1, the dose - rate sh all not exceed 1 μSv/h taking 
account of the background level.  
NOTE Z2  These values appear in Directive 96/29/Euratom of 13 May 
1996.     N/A  
10.6.1   Add   the following paragraph to the end of the 
subclause:  
EN 71 - 1:2011, 4.20 and the related tests methods an d 
measurement distances apply.     N/A  
10.Z1   Add   the following new subclause after 10.6.5.  
10.Z1 Non - ionizing radiation from radio frequencies 
in the range 0 to 300 GHz  
The amount of non - ionizing radiation is regulated by 
European Council Recommendation 1999 /519/EC of 12 
July 1999 on the limitation of exposure of the general 
public to electromagnetic fields (0 Hz to 300 GHz).  
For intentional radiators, ICNIRP guidelines should be 
taken into account for Limiting Exposure to Time -
Varying Electric, Magnetic, and   Electromagnetic Fields 
(up to 300 GHz). For hand - held and body - mounted 
devices, attention is drawn to EN 50360 and EN 50566     N/A  
G.7.1   Add   the following note:  
NOTE Z1  The harmonized code designations corresponding to the 
IEC cord types are given in Anne x ZD.     P