air condition SSANGYONG RODIUS 2006 User Guide

SSANGYONG RODIUS 2006 User Guide RODIUS 2006 SSANGYONG SSANGYONG https://www.carmanualsonline.info/img/67/57523/w960_57523-0.png SSANGYONG RODIUS 2006 User Guide

Page 363 of 444

SSANGYONG RODIUS 2006 User Guide 0-12
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
3. AIR CONDITIONER AND HEATER PIPE LAYOUT

Page 364 of 444

SSANGYONG RODIUS 2006 User Guide 0-13
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
4. SENSORS AND ACTUATORS
1) Sun Sensor
It is installed on the upper left end of instrument panel. It is using characteristics that the 
amount of c

Page 365 of 444

SSANGYONG RODIUS 2006 User Guide 0-14
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
2) Active Incar/Humidity Sensor (AIH Sensor)
The AIH sensor is installed at the driver side  instrument panel undercover. It is a sensor that  
det

Page 366 of 444

SSANGYONG RODIUS 2006 User Guide 0-15
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
(3) Inspection
If the active incar sensor defect code (DTC 1) and the humidity sensor defect code (DTC 10)  
are set, check as below:
Air condition

Page 367 of 444

SSANGYONG RODIUS 2006 User Guide 0-16
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
Humidity sensor ▶
Apply 5 V to terminal No. 1 and 3 on the humidity sensor connector.
Connect the positive (+) probe of a tester on No. 2 termina

Page 368 of 444

SSANGYONG RODIUS 2006 User Guide 0-17
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
5. AIR QUALITY SYSTEM (AQS)
1) Components of AQS
Air Quality System (AQS) changes the air source selection to recirculation mode when polluted  
ai

Page 369 of 444

SSANGYONG RODIUS 2006 User Guide 0-18
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
2) AQS Operation
The AQS operates under air conditioner AUTO mode or when the AQS switch is pressed under  
manual mode. It requires preheating tim

Page 370 of 444

SSANGYONG RODIUS 2006 User Guide 0-19
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
When driving out of polluted area 3.
If the polluted air is disappeared, the air 
source is automatically changed to the fresh 
air mode and AQS LE

Page 371 of 444

SSANGYONG RODIUS 2006 User Guide 0-20
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
3) AQS Operation Circuit
1. Ambient temperature switch
2. Sensor ground
3. AQS signal (Output)
4. Ground
5. IGN 2
[AQS sensor] ▶
Measure the volt

Page 372 of 444

SSANGYONG RODIUS 2006 User Guide 0-21
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
6. AIR CONDITIONER MODULE SENSORS AND ACTUATORS
1) Duct Temperature Sensor
The duct temperature sensor is installed on the top of heater unit. It d