SSANGYONG RODIUS 2006 Owners Manual 0-22
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
2) Power Transistor
The power transistor controls the fan speed. It controls the blower motor operating speed  
without stages by changing the curr

Page 374 of 444

SSANGYONG RODIUS 2006 Owners Manual 0-23
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
3) Mode Door Actuator
The mode door actuator is an actuator that closes, opens and adjusts the mode door for VENT,  
FLOOR and DEF mode to change t

Page 375 of 444

SSANGYONG RODIUS 2006 Owners Manual 0-24
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
(1) Inspection
If the intake door mode on FATC is different from the actual intake door mode, 
check as below. ▶
Turn the ignition switch to ON p

Page 376 of 444

SSANGYONG RODIUS 2006 Owners Manual 0-25
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
4) Air Door Actuator
The air door actuator sets the intake door mode according to the control signals from FATC.

Page 377 of 444

SSANGYONG RODIUS 2006 Owners Manual 0-26
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
(1) Inspection
Terminal arrangementCircuit diagram
If the intake door mode on FATC is different from the actual intake door mode, check 
as below.

Page 378 of 444

SSANGYONG RODIUS 2006 Owners Manual 0-27
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
5) Air Mix Door Actuator
The air mix door actuator controls the discharging air temperature properly by closing/opening  
the damper according to t

Page 379 of 444

SSANGYONG RODIUS 2006 Owners Manual 0-28
RODIUS 2007.07
6810-20 
AIR CONDITIONING SYSTEM
(1) Inspection
Circuit diagram
Terminal arrangement
If the air mix door defect error is indicated, check as below. ▶
Turn the ignition switch to

Page 380 of 444

SSANGYONG RODIUS 2006 Owners Manual 0-29
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20 
6) Thermo AMP
The thermo AMP outputs the compressor ON or OFF signal to ECU to prevent evaporator from  
freezing. The sensing part of the thermist

Page 388 of 444

SSANGYONG RODIUS 2006 Owners Manual 0-9
AIR BAG SYSTEM
RODIUS 2007.07
8810-01
9) Micro Controller
This device receives the impact signal from the sensor for vehicle impact and identifies whether 
the current condition is necessary for a