av system SSANGYONG RODIUS 2007 Service Manual

SSANGYONG RODIUS 2007 Service Manual RODIUS 2007 SSANGYONG SSANGYONG https://www.carmanualsonline.info/img/67/57524/w960_57524-0.png SSANGYONG RODIUS 2007 Service Manual

Page 386 of 465

SSANGYONG RODIUS 2007  Service Manual 0-14
RODIUS 2006.09
6810-20 
AIR CONDITIONING SYSTEM
2) Active Incar/Humidity Sensor (AIH Sensor)
The AIH sensor is installed at the driver side  instrument panel undercover. It is a sensor that  
det

Page 387 of 465

SSANGYONG RODIUS 2007  Service Manual 0-15
AIR CONDITIONING SYSTEM
RODIUS 2006.09
6810-20 
(3) Inspection
If the active incar sensor defect code (DTC 1) and the humidity sensor defect code (DTC 10)  
are set, check as below:
Air condition

Page 388 of 465

SSANGYONG RODIUS 2007  Service Manual 0-16
RODIUS 2006.09
6810-20 
AIR CONDITIONING SYSTEM
Humidity sensor ▶
Apply 5 V to terminal No. 1 and 3 on the humidity sensor connector.
Connect the positive (+) probe of a tester on No. 2 termina

Page 389 of 465

SSANGYONG RODIUS 2007  Service Manual 0-17
AIR CONDITIONING SYSTEM
RODIUS 2006.09
6810-20 
5. AIR QUALITY SYSTEM (AQS)
1) Components of AQS
Air Quality System (AQS) changes the air source selection to recirculation mode when polluted  
ai

Page 390 of 465

SSANGYONG RODIUS 2007  Service Manual 0-18
RODIUS 2006.09
6810-20 
AIR CONDITIONING SYSTEM
2) AQS Operation
The AQS operates under air conditioner AUTO mode or when the AQS switch is pressed under  
manual mode. It requires preheating tim

Page 391 of 465

SSANGYONG RODIUS 2007  Service Manual 0-19
AIR CONDITIONING SYSTEM
RODIUS 2006.09
6810-20 
When driving out of polluted area 3.
If the polluted air is disappeared, the air 
source is automatically changed to the fresh 
air mode and AQS LE

Page 392 of 465

SSANGYONG RODIUS 2007  Service Manual 0-20
RODIUS 2006.09
6810-20 
AIR CONDITIONING SYSTEM
3) AQS Operation Circuit
1. Ambient temperature switch
2. Sensor ground
3. AQS signal (Output)
4. Ground
5. IGN 2
[AQS sensor] ▶
Measure the volt

Page 393 of 465

SSANGYONG RODIUS 2007  Service Manual 0-21
AIR CONDITIONING SYSTEM
RODIUS 2006.09
6810-20 
6. AIR CONDITIONER MODULE SENSORS AND ACTUATORS
1) Duct Temperature Sensor
The duct temperature sensor is installed on the top of heater unit. It d

Page 394 of 465

SSANGYONG RODIUS 2007  Service Manual 0-22
RODIUS 2006.09
6810-20 
AIR CONDITIONING SYSTEM
2) Power Transistor
The power transistor controls the fan speed. It controls the blower motor operating speed  
without stages by changing the curr

Page 395 of 465

SSANGYONG RODIUS 2007  Service Manual 0-23
AIR CONDITIONING SYSTEM
RODIUS 2006.09
6810-20 
3) Mode Door Actuator
The mode door actuator is an actuator that closes, opens and adjusts the mode door for VENT,  
FLOOR and DEF mode to change t