SUZUKI SWIFT 2000 1.G RG413 Service Owners Guide HEATER AND VENTILATION 1A-5
ON-VEHICLE SERVICE
HEATER UNIT
1. Heater core 4. Temperature door assembly 7. Temperature lever assembly Do not reuse
2. Blower fan motor assembly 5. Air outlet control doo

Page 59 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Guide 1A-8 HEATER AND VENTILATION
BLOWER FAN MOTOR RESISTOR
REMOVAL
1) Disconnect negative (–) cable at battery.
2) Disconnect blower fan motor resistor coupler.
3) Remove blower fan motor resistor (1) as

Page 60 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Guide HEATER AND VENTILATION 1A-9
HEATER CONTROL ASSEMBLY
REMOVAL
1) Disconnect negative (–) cable at battery.
2) Remove steering column hole cover.
3) Remove heater control knob (1), center upper garnish

Page 61 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Guide 1A-10 HEATER AND VENTILATION
INSTALLATION
1) Reverse removal procedure for installation.
2) Adjust the following items.
a) Move air outlet control dial (1), temperature control dial (2)
and fresh air

Page 63 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Guide 1A-12 HEATER AND VENTILATION
AIR INLET BOX
REMOVAL
1) Disconnect negative (–) cable at battery.
2) Remove glove box.
3) Disable air bag system by referring to “DISABLING AIR BAG
SYSTEM” in Secti

Page 64 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Guide HEATER AND VENTILATION 1A-13
5) Remove air inlet box mounting nuts (1) and screws (2).
6) Remove air inlet box (3).
INSTALLATION
Reverse removal procedure to install air inlet box noting the fol-
lowi

Page 65 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Guide 1A-14 HEATER AND VENTILATION
INSTALLATION
Reverse removal procedure to install ventilation louver noting the
following instruction.
Be sure to install ventilation louver holder (1) to proper direc-
t

Page 66 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Guide AIR CONDITIONING (OPTIONAL) 1B-1
6F1
6F2
6G
1B
7A
7A1
7B1
7C1
7D
7E
7F
8A
8B
8C
8D
8E
9
10
10A
10B
SECTION 1B
AIR CONDITIONING (OPTIONAL)
CONTENTS
GENERAL DESCRIPTION .............................. 1B

Page 67 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Guide 1B-2 AIR CONDITIONING (OPTIONAL)
REMOVING MANIFOLD GAUGE SET ......  1B-26
LEAK TEST................................................  1B-26
LIQUID LEAK DETECTORS ..................  1B-26
ON-VEHICLE S

Page 68 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Guide AIR CONDITIONING (OPTIONAL) 1B-3
GENERAL DESCRIPTION
REFRIGERANT CIRCULATION
REFRIGERANT TYPE
Whether the A/C in the vehicle being serviced uses HFC-134a
(R-134a) or CFC-12 (R-12) is indicated on comp