check engine light SUZUKI SWIFT 2000 1.G SF310 Service Owner's Manual
[x] Cancel search | Manufacturer: SUZUKI, Model Year: 2000, Model line: SWIFT, Model: SUZUKI SWIFT 2000 1.GPages: 557, PDF Size: 14.35 MB
Page 476 of 557

1. Crankshaft pulley
2. Water pump pulley
A: To be advanced
B: To be retarded
1. Distributor flange bolt
2. Distributor
IGNITION SYSTEM 6F-9
IGNITION TIMING
NOTE:
Before starting engine, place transmission gear shift lever in
“Neutral” (shift selector lever to “P” range for A/T model), and
set parking brake.
INSPECTION AND ADJUSTMENT
1) Connect SUZUKI scan tool (1) to DLC (2) with ignition switch
OFF.
2) Start engine and warm it up to normal operating temperature.
3) Make sure that all of electrical loads except ignition are
switched off.
4) Check to be sure that idle speed is within specification.
(Refer to SECTION 6E1)
5) Set timing light to No.1 high-tension cord.
6) Fix ignition timing to initial one as follows:
Select “MISC” made on SUZUKI scan tool and fix ignition tim-
ing to initial one.
7) Using timing light, check that timing is within specification.
Initial ignition timing (Ignition timing fixed):
5 ±3 BTDC (at idle speed)
Ignition order: 1-3-2
Special Tool
(A): 09900-27301 or 09930-76420
8) If ignition timing is out of specification, loosen flange bolts, ad-
just timing by turning distributor assembly while engine is run-
ning, and then tighten bolts.
Tightening Torque
(a): 15 N
.m (1.5 kg-m, 11.0 lb-ft)
9) After tightening distributor flange bolts, recheck that ignition
timing is within specification.
10) After checking and/or adjusting Initial Ignition Timing, release
ignition timing fixation by SUZUKI scan tool.
11) With engine idling (ignition timing not fixed, idle switch ON and
car stopped), check that ignition timing is about 10 BTDC.
(Constant variation within a few degrees from 10 indicates no
abnormality but proves operation of electronic timing control
system.) Also, check that increasing engine speed advances
ignition timing.
If above check results are not satisfactory, check CTP switch,
test switch terminal circuit and ECM.
Page 487 of 557

6F1-8 IGNITION SYSTEM (SFI FOR G13)
5) Fix ignition timing to initial one as follow.
Select “MISC” mode on SUZUKI scan tool and fix ignition tim-
ing to initial one.
6) Detach air cleaner case and shift air cleaner case and hose
position to observe ignition timing.
7) Using timing light (1), check that ignition timing is within specifi-
cation.
Initial ignition timing (fixed with
SUZUKI scan tool) : 5 3 BTDC at idle speed
Ignition order : 1-3-4-2
8) If ignition timing is out of specification, check the followings:
CKP sensor
Crankshaft timing belt pulley (signal rotor)
TP sensor
VSS
Timing belt cover installation
9) After checking Initial Ignition Timing, release ignition timing
fixation by using SUZUKI scan tool.
10) With engine idling (throttle opening at closed position and ve-
hicle stopped), check that ignition timing is about 9–15
BTDC. (Constant variation within a few degrees from 9–15
indicates no abnormality but proves operation of electronic tim-
ing control system.) Also, check that increasing engine speed
advances ignition timing.
If above check results are not satisfactory, check CKP sensor
and ECM (PCM).
11) Install air cleaner case.
Page 539 of 557

8G
IMMOBILIZER CONTROL SYSTEM 8G-1
GENERAL DESCRIPTION8G- 2 . . . . . . . . . . . . . .
On-Board Diagnostic System
(Self-Diagnosis Function) 8G- 4. . . . . . . . . . . . .
DIAGNOSIS8G- 6 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Precautions in Diagnosing
Troubles 8G- 6. . . . . . . . . . . . . . . . . . . . . . . . . . .
DIAGNOSTIC FLOW TABLE 8G- 8. . . . . . . . . . . . .
Diagnostic Trouble Code Check
(Immobilizer Control Module) 8G-10. . . . . . . . .
Diagnostic Trouble Code Check (ECM) 8G-10. .
Diagnostic Trouble Code Table 8G-12. . . . . . . . .
A-1 Code (DTC) is not Outputted
from Diagnostic Output Terminal
of Immobilizer Diagnostic Coupler 8G-13. . . . . A-2 Immobilizer Indicator Lamp Check
(Immobilizer Indicator Lamp does not
Light at Ignition Switch ON) 8G-14. . . . . . . . . . .
A-3 Immobilizer Indicator Lamp Check
(Immobilizer Indicator Lamp Remains
ON after Engine Starts) 8G-15. . . . . . . . . . . . . .
HOW TO REGISTER IGNITION KEY8G-16 . . . . .
PROCEDURE AFTER IMMOBILIZER
CONTROL MODULE REPLACEMENT8G-17 . .
PROCEDURE AFTER ECM
REPLACEMENT8G-18 . . . . . . . . . . . . . . . . . . . . . .
SPECIAL TOOLS8G-18 . . . . . . . . . . . . . . . . . . . . . .
SECTION 8G
IMMOBILIZER CONTROL SYSTEM
WARNING:
For vehicles equipped with Supplemental Restraint (Air Bag) System:
Service on and around the air bag system components or wiring must be performed only by an autho-
rized SUZUKI dealer. Refer to “Air Bag System Components and Wiring Location View” under “Gener-
al Description” in air bag system section in order to confirm whether you are performing service on
or near the air bag system components or wiring. Please observe all WARNINGS and “Service Precau-
tions” under “On-Vehicle Service” in air bag system section before performing service on or around
the air bag system components or wiring. Failure to follow WARNINGS could result in unintentional
activation of the system or could render the system inoperative. Either of these two conditions may
result in severe injury.
Technical service work must be started at least 90 seconds after the ignition switch is turned to the
“LOCK” position and the negative cable is disconnected from the battery. Otherwise, the system may
be activated by reserve energy in the Sensing and Diagnostic Module (SDM).
NOTE:
Whether the immobilizer indicator lamp is used in the particular vehicle or not depends on specifica-
tions. If there is a monitor coupler in the engine room near the left strut assembly, the vehicle is not
equipped with immobilizer indicator lamp and if there isn’t, it is equipped with immobilizer indicator
lamp.
For the descriptions (items) not found in this section, refer to the section 8G of the Service Manual men-
tioned in FOREWORD of this manual.
CONTENTS
Page 546 of 557

8G-8 IMMOBILIZER CONTROL SYSTEM
Fig. 1 for Step 1 Fig. 2 for Step 1 Fig. 3 for Step 2
1. Monitor coupler
2. Service wire
A: Diagnosis switch terminal
B: Ground terminal
Fig. 4 for Step 3
“CHECK ENGINE” light
0.5
ON
OFF
TIME (sec.)
DIAGNOSTIC FLOW TABLE
STEPACTIONYESNO
11) Make sure that diagnosis switch
terminal in monitor coupler is not
grounded by service wire. See Fig. 1.
2) Check malfunction indicator lamp
while ignition switch is ON (but without
starting engine). See Fig. 2.
Dose malfunction indicator lamp flash?Go to Step 3.If malfunction indicator lamp
remains ON, go to Step 2.
If malfunction indicator lamp
remains OFF, go to
“MALFUNCTION INDICATOR
LAMP CHECK” in Section 6.
21) Using service wire, ground diagnosis
switch terminal in monitor coupler.
See Fig. 3.
Dose malfunction indicator lamp flash?Immobilizer control
system is in good
condition.Go to “MALFUNCTION
INDICATOR LAMP CHECK” in
Section 6.
3Dose malfunction indicator lamp flash as
Fig. 4?Go to Step 4.Go to “MALFUNCTION
INDICATOR LAMP CHECK” in
Section 6.
41) Check DTC stored in Immobilizer
Control Module referring to
“DIAGNOSTIC TROUBLE CODE
CHECK (IMMOBILIZER CONTROL
MODULE)” in this section.
Is there any DTC(s)?Go to flow table for
DTC No.Go to Step 5.
51) Check DTC stored in ECM referring to
“DIAGNOSTIC TROUBLE CODE
CHECK (ECM)” in this section.
Is there any DTC(s)?Go to flow table for
DTC No.Substitute a known-good ECM
and recheck.
NOTE:
After replacing with a known-
good ECM, register ECM /
Immobilizer Control Module
code in ECM by performing
procedure described in
“Procedure after ECM
Replacement” section.
Page 552 of 557

8G-14 IMMOBILIZER CONTROL SYSTEM
1. Main fuse
2. Main relay
3. ECM
4. Immobilizer indicator lamp
(Vehicle not equipped with
monitor coupler)For G10 engine
For G13B engine
For G10 engine For G13B engine
A-2 IMMOBILIZER INDICATOR LAMP CHECK
(IMMOBILIZER INDICATOR LAMP DOSE NOT LIGHT AT IGNITION SWITCH ON)
STEPACTIONYESNO
11) Turn ignition switch ON.
Do other indicator / warning lights in
combination meter come ON?Go to Step 2.“IG” fuse blown, main fuse blown,
ignition switch malfunction,
“(d)” circuit between “IG” fuse
and combination meter or poor
coupler connection at
combination meter.
21) Turn ignition switch OFF and
disconnect connectors from ECM.
2) Check for proper connection to ECM
at terminal C02-18 for G10 engine or
C01-28 for G13B engine.
3) If OK, then using service wire, ground
terminal C02-18 for G10 engine or
C01-28 for G13B engine in connector
disconnected.
Does immobilizer indicator lamp turn on
at ignition switch ON?Substitute a known-
good ECM and
recheck.Bulb burned out or “(P)” wire
circuit open.