blower SUZUKI SWIFT 2005 2.G Service Owner's Manual

SUZUKI SWIFT 2005 2.G Service Owner's Manual SWIFT 2005 2.G SUZUKI SUZUKI https://www.carmanualsonline.info/img/20/7607/w960_7607-0.png SUZUKI SWIFT 2005 2.G Service Owner's Manual

Page 284 of 1496

SUZUKI SWIFT 2005 2.G Service Owners Manual Downloaded from www.Manualslib.com manuals search engine 1C-12 Engine Electrical Devices: 
MAF and IAT Sensor InspectionS7RS0B1306020
CAUTION! 
Do not heat up MAF and IAT sensor more 
than 100 °C (21

Page 415 of 1496

SUZUKI SWIFT 2005 2.G Service Owners Manual Downloaded from www.Manualslib.com manuals search engine Charging System:  1J-5
Generator Test (Undercharged Battery Check)S7RS0B1A04003
This condition, as evidenced by slow cranking or 
indicator cle

Page 933 of 1496

SUZUKI SWIFT 2005 2.G Service Owners Manual Downloaded from www.Manualslib.com manuals search engine Table of Contents 7- i
7
Section 7
CONTENTS
HVAC
Precautions ................................................. 7-1
Precautions.................

Page 934 of 1496

SUZUKI SWIFT 2005 2.G Service Owners Manual Downloaded from www.Manualslib.com manuals search engine 7-ii Table of Contents
Recommended Service Material ....................... 7B-33
Special Tool ................................................

Page 937 of 1496

SUZUKI SWIFT 2005 2.G Service Owners Manual Downloaded from www.Manualslib.com manuals search engine Heater and Ventilation:  7A-1
HVAC
Heater and Ventilation
General Description
Heater and Ventilation ConstructionS7RS0B7101001
NOTE
The figure

Page 938 of 1496

SUZUKI SWIFT 2005 2.G Service Owners Manual Downloaded from www.Manualslib.com manuals search engine 7A-2 Heater and Ventilation: 
Schematic and Routing Diagram
Heater and Ventilation Wiring Circuit DiagramS7RS0B7102001
2. Ventilator duct 6. Fo

Page 939 of 1496

SUZUKI SWIFT 2005 2.G Service Owners Manual Downloaded from www.Manualslib.com manuals search engine Heater and Ventilation:  7A-3
Diagnostic Information and Procedures
Heater and Ventilation Symptom DiagnosisS7RS0B7104001
ConditionPossible cau

Page 940 of 1496

SUZUKI SWIFT 2005 2.G Service Owners Manual Downloaded from www.Manualslib.com manuals search engine 7A-4 Heater and Ventilation: 
Repair Instructions
HVAC Unit ComponentsS7RS0B7106001
For manual type A/C, refer to “HVAC Unit Components 
in S

Page 941 of 1496

SUZUKI SWIFT 2005 2.G Service Owners Manual Downloaded from www.Manualslib.com manuals search engine Heater and Ventilation:  7A-5
• Check for operation and current.a. Put blower motor (1) in a soft-jawed vise.
b. Connect battery to blower mo

Page 942 of 1496

SUZUKI SWIFT 2005 2.G Service Owners Manual Downloaded from www.Manualslib.com manuals search engine 7A-6 Heater and Ventilation: 
Blower Motor Relay InspectionS7RS0B7106007
1) Remove junction block assembly referring to “BCM (Included in Jun