air conditioning TOYOTA AVENSIS 2005 Service Owner's Manual
[x] Cancel search | Manufacturer: TOYOTA, Model Year: 2005, Model line: AVENSIS, Model: TOYOTA AVENSIS 2005Pages: 5135, PDF Size: 95.28 MB
Page 1113 of 5135

I35392
DTCDEF
I35417ECU±B2
Fuse block:
3
2
145678
910111213141516
DLC3
A04550
05±1092
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
3.DTC CHECK (SENSOR CHECK)
(a)After the indicator check is completed, the system enters the DTC check mode automatically.
(b)Read the codes displayed on the panel. Refer to the list of codes on page 05±1094 when reading the codes.
(Trouble codes are outputed at the temperature display.)
(c) If the slower display is desired, press the DEF switch and
change it to the stop operation. Each time the DEF switch
is pressed, the display changes by 1 step.
4. CLEARING DTC
(a) To clear diagnostic trouble code, there are 2 ways. (1) During sensor check, press the ºDEFº switch andºDUALº switch at the same time.
(2) Pull the ECU±B2 fuse in fuse block for 20 seconds or longer to clear the DTC memory.
5. CHECK DLC3
(a) The vehicle engine and ECT ECU uses the ISO 9141±2 (Euro±OBD)/ISO 14230 (M±OBD) communication proto-
col. The terminal arrangement of the DLC3 complies with
ISO 15031±3 and matches the ISO 9141±2/ISO 14230
format.
Terminal No.Connection/Voltage or ResistanceCondition
7Bus + Line/Pulse generationDuring transmission
4Chassis Ground Body Ground/1 or lessAlways
5Signal Ground Body Ground/1 or lessAlways
16Battery Positive Body Ground/9 ± 14 VAlways
Page 1114 of 5135

I36146
Display code R/FDEFLHD:
I36147
Display code RHD:R/FDEF
Blower level Step No.Display
codeConditions
Air flow bent Air inlet damper Compressor
ºCOOLº side (Full closed)Air mix damper
OFF FRESH
FACE 0
1
2
3
6
7
8
9
104
51
16
16
16
16
16
16
16
31 0
1
2
3
6
7
8 4
5
9FACE
FACE
FACE
B/L
FOOT1
FOOT/ DEF.
DEF.FRESH
ON
ON
ON
ON
ON
ON
ONºCOOLº side (Full closed)
ºCOOLº side (Full closed)
ºCOOLº side (Full closed)
ºCOOLº/ ºHOT º (50 % open)
ºHOTº side (Full opened)
FOOT FACE1FRESH
FRESH
RECIRCULATION
RECIRCULATION
RECIRCULATION
RECIRCULATION
RECIRCULATION
RECIRCULATIONHot gas magnetic valve
ºCOOLº/ ºHOT º (50 % open)
ºHOTº side (Full opened)
ºHOTº side (Full opened)ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF OFF
ºHOTº side (Full opened) OFF
± DIAGNOSTICSAIR CONDITIONING SYSTEM
05±1093
AVENSIS REPAIR MANUAL (RM1018E)
6. ACTUATOR CHECK
(a) After entering the DTC check mode (Sensor Check
Mode) press the R/F switch.
(b) Since each damper, motor and relay automatically oper-
ates at 1 second intervals beginning in order from 10 in
the temperature display, check the temperature and air
flow from visual and by hand.
If the slower display is desired, press the DEF switch and
change it to step operation. Each time the DEF switch is
pressed, the display changes by 1 step.
HINT:
Codes are displayed from the smaller to the larger num-
bers in order.
To cancel the check mode, press the OFF switch.
Page 1115 of 5135

050TH±09
I30150
Inspector 's name:
Customer 's NameVIN
Production Date
Licence No.
Odometer Readingkm
Miles Date vehicle
Brought In / /
Date of Problem Occurrence
How Often does Problem Occur?
Weather
Outdoor Temperature / /
Continuous Intermittent ( times a day)
Fine Cloudy Snowy Various / Other
Hot Warm Cool Cold (Approx.F
C)
Symptoms Blower motor does not operate
Blower motor speed does not change
(Always Hi, Always Mid, Always Lo) Air Flow Control
Faulty
Cabin temperature does not go down
Response is slow
Cannot change between FRS and REC
(Always Fresh or always Recirculating)
Will not enter the desired mode Temperature
Control Faulty
Air Inlet Control
Faulty
Vent Control
Faulty
DTC Check1st Time
2nd Time Normal Code Malfunction Code (Code )
Normal Code Malfunction Code (Code )
AIR CONDITIONING SYSTEM Check Sheet
Cabin temperature does not rise
Mode will not change 05±1090
± DIAGNOSTICSAIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
CUSTOMER PROBLEM ANALYSIS CHECK
Page 1116 of 5135

050TG±11
05±1088
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
AIR CONDITIONING SYSTEM
HOW TO PROCEED WITH TROUBLESHOOTING
1VEHICLE BROUGHT TO WORK SHOP
2CUSTOMER PROBLEM ANALYSIS (See page 05±1090)
3CHECK AND CLEAR DTC (See page 05±1091)
4 PROBLEM SYMPTOM CONFIRMATION
SYMPTOM OCCUR (GO TO STEP 6)
SYMPTOM DOES NOT OCCUR (GO TO
STEP 5)
5SYMPTOM SIMULATION (See page 01±22)
6DTC CHECK (See page 05±1091)
MALFUNCTION CODE (GO TO STEP 7)
NORMAL CODE (GO TO STEP 8)
7DTC CHART (See page 05±1094)
GO TO STEP 10
8PROBLEM SYMPTOMS TABLE (See page 05±1100)
9ACTUATOR CHECK (See page 05±1091)
Page 1117 of 5135

±
DIAGNOSTICS AIR CONDITIONING SYSTEM
05±1089
AVENSIS REPAIR MANUAL (RM1018E)
10 CIRCUIT INSPECTION ( See page 05±1102 to 05± 1159 )
11 IDENTIFICATION OF PROBLEM
12 PARTS INSPECTION
13 REPAIR
14 CONFIRMATION TEST
15 END
Page 1140 of 5135

I35378
A23
Air Mix Control Servo Motor (Driver Side) A/C Control Assembly
M
MAX
HOT4P±L
A15 AMDH12
MAX
COOL5B
A15 AMDC11
PT 3GR
A16 TPD8
VZ 2Y±B
A16 S5±22
GND 1Y±R
A15 SG±214
± DIAGNOSTICSAIR CONDITIONING SYSTEM
05±1139
AVENSIS REPAIR MANUAL (RM1018E)
DTC 46 AIR MIX DAMPER CONTROL SERVOMOTOR
CIRCUIT (DRIVER SIDE)
CIRCUIT DESCRIPTION
The air mix damper servo sub±assy is controlled by the A/C amplifier and moves the air mix damper to the
desired position.
DTC No.Detection ItemTrouble Area
46Air mix damper position sensor value does not change even if
A/C amplifier operated air mix damper control servomotor.
Air mix damper servo sub±assy (air mix damper control )
Harness or connector between air mix damper servo sub±
assy (air mix damper control servomotor) and A/C amplifier
A/C amplifier assy
WIRING DIAGRAM
05A8A±02
Page 1141 of 5135

05±1140
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
1PERFORM ACTUATOR CHECK
(a)Set the actuator check mode (See page 05±1091).
(b) Press the DEF switch (driver side) and change to the step operation.
(c) Check the air flow temperature by hand.
Display CodeAir Mix Damper Operation
0COOL side (0 % open)
1COOL side (0 % open)
2COOL side (0 % open)
3COOL side (0 % open)
4COOL/HOT (50% open)
5COOL/HOT (50% open)
6HOT side (100% open)
7HOT side (100% open)
8HOT side (100% open)
9HOT side (100% open)
NG PROCEED TO NEXT CIRCUIT INSPECTION SHOWN ON PROBLEM SYMPTOMS TABLE
OK
Page 1142 of 5135

I35383
RHD Models:
MAX. COOL MAX. HOT
1
2
3
4
5
MAX HOTMAX COOL
I36141
LHD Models:
MAX. COOL MAX. HOT
MAX HOTMAX COOL
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
05±1141
AVENSIS REPAIR MANUAL (RM1018E)
2INSPECT AIRMIX DAMPER SERVO SUB±ASSY
(a)Remove the air mix damper servo sub±assy.
(b)Connect the positive (+) lead from the battery to terminal
MAX HOT and negative (±) lead to terminal MAX COOL,
then check that the lever turns to ºHOTº side smoothly.
(c)Connect the positive (+) lead from the battery to terminal MAX COOL and negative (±) lead to terminal MAX HOT,
then check that the lever turns to ºCOOLº side smoothly.
NGREPLACE AIRMIX DAMPER SERVO SUB±ASSY
OK
3CHECK HARNESS AND CONNECTOR(AIRMIX DAMPER SERVO SUB±ASSY ± A/C AMPLIFIER)
(a)Check for an open or short circuit in harness and connector between air mix c\
ontrol servomotor and
A/C amplifier (See page 01±32).
NG REPAIR OR REPLACE HARNESS ORCONNECTOR
OK
REPLACE AIR CONDITIONING AMPLIFIER
Page 1143 of 5135

I35378
A25
Air Vent Mode Control Servo Motor A/C Control Assembly
M
FACE 5L±B
A15 AOF4
DEF 4LG±B
A15 AOD3
PT 3GR±R
A16 TPM19
VZ 2BR±W
A16 S5±314
GND 1G±W
A15 SG±315 05±1136
± DIAGNOSTICSAIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
DTC 43 AIR OUTLET DAMPER CONTROL
SERVOMOTOR CIRCUIT
CIRCUIT DESCRIPTION
This circuit turns the servomotor and changes each mode damper position by the signals from the A/C ampli-
fier assy. When the AUTO switch is on, the A/C amplifier changes the mode automatically between ºFACEº,
ºBI±LEVELº, ºFOOTº and ºFOOT/DEFº according to the temperature setting.
DTC No.Detection ItemTrouble Area
43Air mode damper position sensor value does not change even
if A/C amplifier operated mode damper control servomotor.
Mode damper servo sub±assy (mode damper control)
Harness or connector between mode damper servo sub±
assy (mode damper control) and A/C amplifier assy
A/C amplifier assy
WIRING DIAGRAM
05A87±02
Page 1144 of 5135

±
DIAGNOSTICS AIR CONDITIONING SYSTEM
05±1137
AVENSIS REPAIR MANUAL (RM1018E)
INSPECTION PROCEDURE
1PERFORM ACTUATOR CHECK
(a)Warm up engine.
(b)Set the actuator check mode (See page 05±1091).
(c) Press the DEF switch and change it to the step operation.
(d) Check the air flow by hand.
Display codeAir flow condition
0FACE
1FACE
2FACE
3FACE
4FACE1
5B/L
6FOOT1
7FOOT
8FOOT/DEF
9DEF
OK PROCEED TO NEXT CIRCUIT INSPECTION
SHOWN ON PROBLEM SYMPTOMS TABLE
NG