DACIA SOLENZA 2004 Repair Manual

Page 121 of 891

IGNITION AND INJECTION
17
17 - 27
DF003
P RESENT
OR
MEMORIZEDAIR TEMPERATURE SENSOR CIRCUIT
1. DEF : Open circuit or short-circuit
RECOMMENDATIONS
AF TER
REPARATION
C heck the connection and the state of the air temperature sensor connector.
R eplace the sensor ’s connector if necessary.
C heck that resistance of air temperature se nsor is not zero or infinite (sensor sur e failure).
(Use chapter “Help” in order to compare the measured resistance values compared with
recommend ed ones).
R eplace the air te mperature se nsor if necessary.
C onnect the 90 w ays terminal box instead of the injection c omputer then c heck the insulation,
continuity and absence of the parasite resistance on lines: Pin 77 injection computer > pin 1 air temperature sensor
Pin 49 injection computer > pin 2 air temperature sensor
Fix if necessary
C heck the correct evolution of the sensor resistance subject to ai r temperature.
R eplace the air te mperature se nsor if necessary.
If the problem is persisting after these checking, fix the other failures the n perform the conformity
checking.
Diagnostic – Failures interpretation
If failure “DF345 : Supply 5 volts potentiometers or transducers” is present
or memorized, this must be treated with priority.
C onditions for failure detection by the computer:
- Set the contact on
- If the failure is only memorized, st art the engine in order to obtain a temperature
variation ( an engine cooling fan starting).
(The failure must pass to the present state, but it may become again memorized
i mmediately after finishing performing the previous operations).
* If the failure is memorized with OBD indicator on, check in the context part,
if state “ET274 : Air tempe rature se nsor circuit” corresponding to the OBD
i ndicator lighting request is affirmative. In this case, proceed as per bellow
m entioned method.
Perform the operations from “recommendations” for reparation confirmation.
Fix a ny other possible failures.
Erase the failures memoriz ed by the injection computer.
Perform a conformity checking by means of the CLIP tester.
vnx.su

Page 122 of 891

IGNITION AND INJECTION
17
17 - 28
Diagnostic – Failures interpretation
DF004
P RESENT
OR
MEMORIZEDWATER TEMPERATURE SENSOR CIRCUIT
1. DEF : Open circuit or short-circuit
RE CO MMENDATIONS
AFTER
REPARATION
C heck the connection and the state of the air tempe ratur e sensor connector.
Re place the connector if necessary.
C heck tha t resistance of wate r te mperatur e se nsor is not zero or infinite (sensor sur e failure).
Use chapter “Help” in order to compare the measured resistance values compared with
recommend ed ones).
Repl ace the wate r tempe ratur e se nsor if necessary.
C onnect the 90 w ays terminal box instead of the injection c omputer then c heck the insulation,
continuity and absence of the parasite resistance on lines: Pin 73 injection computer > pin B1 water temperature sensor
Pin 13 injection computer > pin B2 water temperature sensor
Fix if necessary
C heck the correct evolution of the sensor resistance subject to the temperature.
Repl ace the wate r tempe ratur e se nsor if necessary.
If the problem is persisting after these checking, fix the other failures the n perform the conformity
checking.
If failure “DF345 : Supply 5 volts potentiometers or transducers” is present
or memorized, this must be treated with priority.
Conditions for failure detection by the compu ter:
- Set the contact on
- If the failure is only memorized, st art the engine in order to obtain a temperature
variation (an engine cooling fan starting).
(The failure must pass to the present state, but i t may become again memorized
imme diately after finishing performing the previous operations).
* If the failure is memorized with OBD indicator on, check in the context part,
if state “ET275 : Water temperature sensor circuit” c orresponding to the
OBD indicator lighting request is affirma tive. In this case, proceed a s per
bellow mentioned method.
P erform the operations from “recommendations” for reparation confirmation.
Fix a ny other possible failures.
Erase the failures memoriz ed by the injection computer.
Perform a conformity checking by means of the CLIP tester.
vnx.su

Page 123 of 891

IGNITION AND INJECTION
17
17 - 29
AFTER
REPARATION P
erform the operations from “recommendations” for reparation confirmation.
Fix a ny other possible failures.
Erase the failures memoriz ed by the injection computer.
Perform a conformity checking by means of the CLIP tester.
C heck the c onnection and the state of the de tonation sensor connector.
R eplace the sensor ’s connector if necessary.
C heck the tightening of the RPM sensor on the engine block
Fi x if necessary.
C onnect the 90 w ays terminal box instead of the injection c omputer then c heck the insulation,
continuity and absence of the parasite resistance on lines:
Pin 20 injection computer > p in 1 detonation sensor
Pin 79 injection computer > p in 2 detonation sensor
Pin 19 injection computer > RPM sensor sc reening
Fix if necessary
If the problem is persisting after these checking, fix the other failures the n perform the conformity
checking.
RE CO MMENDATIONS
Conditions for diagnostic application for memorized failure:
Perform a road test with warm and in charge engine.
* If the failure is memorized with OBD indicator on, check in the context part,
if state “ET289 : Detonation sensor cir cuit” corresponding to the OBD
i ndicator lighting request is affirmative. In this case , proceed as per bellow
m entioned method.
Diagnostic – Failures interpretation
DF006
P RESENT
OR
ME MO RIZEDDETONATION SENSOR CIRCUIT
1. DEF : Open circuit or short-circuit
vnx.su

Page 124 of 891

IGNITION AND INJECTION
17
17 - 30
AFTER
REPARATION
Perform the operations from “recommendations” for repara tion confirmation.
Fix a ny other possible failures.
Erase the failures memoriz ed by the injection computer.
Perform a conformity checking by means of the CLIP tester.
C heck the battery and electric mass condition of the veh icle.
Fi x if necessary.
C heck the connection and the connector condition of the actuator s relay .
C hange the connector if necessary.
C heck the presence of +12 Volts at pin 1 actuators relay.
Fi x if necessary.
C heck the actuators relay coil.
R eplace the actuators relay if necessary.
C heck the insulation and continuity on line
Pin 39 injection computer > pin 2 actuators relay.
Fix if necessary
If the problem is persisting after these checking, fix the other failures the n perform the conformity
checking.
RE CO MMENDATIONS
Conditions for diagnostic appl ication for memorized failure:
Set t he contact on then enter in dialog with the injection computer by means
of the CLIP tester.
REMARK: This failure is of high importance. It is then necessary to be
tr eate d before the following ones.
Diagnostic – Failures interpretation
DF009
P RESENT
OR
ME MO RIZEDACTUATORS RELAY CONTROL CIRCUIT
1DEF : Open circuit or short-circuit
CO : open circuit
CC.O : s hot circuit at mass
CC.1 : s hort circuit at + 12 V.
vnx.su

Page 125 of 891

IGNITION AND INJECTION
17
17 - 31
DF012
P RESENT
OR
ME MO RIZEDINJECTION > AC CONNECTION
No comments failure
RE CO MM ENDATIONS
Conditions for diagnostic appl ication for memorized failure :
Failure is declared present further to a 10 seconds timing with engine running
and climate control under operation, state ET009: active (during test, battery
voltage must be not under 11 V).
AF TER
REPARATION Pe
rform the operations from “recommendations” for reparation confirmation.
Fi x any other possible failures.
Erase the failures memoriz ed by the injection computer.
Pe rform a conformity checking by means of the CLIP tester.
Diagnostic – Failures interpretation
Connect the 90 ways terminal box instead of the injection computer then check the insulation,
continuity and absence of the parasite resistance on line 32 of the injection computer.
Fi x if necessary.
Re fer to climate control diagnostic if the incident is persisting.
vnx.su

Page 126 of 891

IGNITION AND INJECTION
17
17 - 32
DF014
P RESENT
OR
ME MO RIZEDCANISTER PURGING VALVE CIRCUIT
1.DEF : Open circuit or short-circuit
CO : Open circuit
CC.O : S hot circuit at mass
CC. 1 : Short circuit at + 12 V.
RECO MMENDATIONS
Conditions for diagnostic appl ication for memorized failure:
Se t the contact on or launch commend “AC016: Canister Purging Valve”
In ca se of failures additi on, treat as most important failure “DF009 actuators
relay control circuit ”.
* If the failure is memorized with OBD indicator on, check in the context part,
if state “ET117 : Canister purging control” corresponding to the OBD i ndicator
lighting request is affirma tive. In this case, proceed as per bellow mentioned
met hod.
C heck the connection and the connector state of the can ister purging valve .
C hange the connector if necessary.
C heck the resistance of the canister purging valve.
Repl ace the canister purging valve if is necessary.
C heck with the contact on, the presence of +12 Volts at pin 1 of the purging valve .
Fi x if necessary.
C onnect the 90 ways terminal box instead of the injection computer the n check the in s u la t ion and
the continuity of the l ine:
Pin 4 injection computer > pin 2 canister purging valve
Fix if necessary
Repl ace the canister purging valve if necessary.
If the problem is persisting after these checking, fix the other failures then perform the conformity
checking.
AFT ER
REPARATION Pe
rform the operations from “recommendations” for reparation confirmation.
Fi x any other possible failures.
Erase the failures memoriz ed by the injection computer.
Pe rform a conformity checking by means of the CLIP tester.
Diagnostic – Failures interpretation
vnx.su

Page 127 of 891

IGNITION AND INJECTION
17
17 - 33
RE CO MM ENDATIONS
In order to perform this diagnostic, the pressure sensor must be not in
failure.
Conditions for diagnostic appl ication for memorized failure :
Se t the contact off and wait until the communication computer-CLIP tester
is lost.
Set the contact on, enter in dialog with the computer and eras e the memorized
failures. Act upon the starter for 10 seconds or make the engine idle running.
* If the failure is memor ized with OBD indicator on, check in the conte xt
part, if sta te “ET276 : Engine flywheel tooting dama ge” corresponding to
t he OBD indicator lighting request is affirma tive. In this case, proceed as
per bellow mentioned method.
AF TER
REPARATION
RPM SIGNAL INFORMATION
1. DEF : Engine flywheel tooting damage
2. DEF: tooth signal abse nce
C heck the connection and the condition of the RPM sensor connector
R eplace the connector if necessary.
C heck the cleaning state and the correct attachment of the RPM sensor
Fi x if necessary.
C heck the resistance of the RPM sensor.
R eplace the RPM sensor if necessary.
C onnect the 90 ways terminal box instead of the injection computer then c heck the insulation,
continuity and absence of the parasite resistance on lines: Pin 54 injection computer > p in A RPM sensor
Pin 24 injection computer > pi n B RPM sensor
Fi x if necessary.
If 1. DEF is occurring, check the engine flywheel condition.
If the problem is persisting after these checking, fix the other failures then perform the conformity
checking.
Diagnostic – Failures interpretation
DF017
P RESENT
OR
ME MO RIZED
Che ck tha t state “ ET202: Dia gnostic OBD c ombustion misfires taken into
consideration”, is ACTIVE. Contrary, it is necessary, the re-act ivation of “learning”
t he RPM signal by the injection computer.
Fix the others possible failures and then perform the conformity checking.
vnx.su

Page 128 of 891

IGNITION AND INJECTION
17
17 - 34
UPSTREAM OXYGEN SENSOR HEATING CIRCUIT
1DEF : Open circuit or short-circuit
CO : open circuit
CC.O : s hot circuit at mass
CC.1 : s hort circuit at + 12 V.

DF018
P RESENT
OR
MEMO RIZED
Conditions for diagnostic appl ication for memorized failure :
- Start the engine and ensure that state “ AC261: Upstream O2 sensor
heating” is ACTIVE.
- Or act upon the actua tor control “ AC261: upstream 02 sensor heating ”.
In case of failures addition, treat as most important failure “DF009 actuators
relay control circuit” .
* If the failure is memorized with OBD indicator on, check in the context part,
if state “ET117 : Cani ster purging control” corresponding to the OBD i nd icator
lighting request is affirmative. In this case, proceed as per bellow mentioned
met hod.
RECOMMENDATIONS
Perform the operations from “recommendations” for reparation confirmation.
Fi x any other possible failures.
Erase the failures memoriz ed by the injection computer.
Pe rform a conformity checking by means of the CLIP tester.
AF
TER
REPARATION
Diagnostic – Failures interpretation
C heck the connection and the connector state of the oxygen sensor.
C hange the connector if necessary.
C heck the heating resistance of the oxygen sensor. Refer to chapter ” Help” for res istance values .
Repl ace the sensor if necessary.
C heck the presence of +12 Volts on A way of the oxygen s ensor.
Fi x the electric connection between A way oxygen sensor and the actuators relay.
C onnect the 90 ways terminal box instead of the injection computer then check the insulati on, the
continuity and the abse nce of the parasite resistance on line: :
Pin 63 injection computer > pin B oxygen sensor
Fi x if necessary.
If the problem is persisting after these checking, fix the other failures then perform the conformity
checking.
vnx.su

Page 129 of 891

IGNITION AND INJECTION
17
17 - 35
DF 022
P RESENTINJECTION COMPUTER
1 . DEF : Replace the computer
Nothing to mention.
Pe rform a road test followed then by a new checking by means of the CLIP tester.
Pe rform the operations from ” recommendations” for reparation confir mation
Fi x any other possible failures.
Erase the failures memoriz ed by the injection computer.
Pe rform a conformity checking by means of the CLIP tester.
AF TER
REPARATION
RECOMMENDATIONS
Non-conform or damaged computer.
C heck if the computer the one specific for that type of vehicle .
Do not immediately replace the computer without identifying preci sely its damaging cause.
Pe rform the following procedure:
Se t th e contact on and ente r in dialog with the computer.
Erase the failures memoriz ed by the injection computer.
Set the contact off and wait for the interruption of the communication computer-CLIP te ster.
Se t the contact on and then enter in dialog with the computer
If the failure is persisting, replace the computer.
Diagnostic – Failures interpretation
vnx.su

Page 130 of 891

IGNITION AND INJECTION
17
17 - 36
DF 032
P RESENT
OR
ME MO RIZEDWATER TEMPERATURE WARNING CIRCUIT
1D EF : Open circuit or short-cir cuit
CO : open circuit
CC.O : short-circuit at mass
CC.1 : shot-circuit at + 12 volts
RECO MMENDATI O N S
Conditions for diagnostic appl ication for memorized failure :
St art the engine and maintain it at over 1500 rot/min until engine fun
st arting or act upon control AC212: Water temperatu re warning indicator.
Check the connection and the condition of the connector on the line over-heating indicator .
Re place the connector if necessary.
C heck the indicator condition ( if by chance this is on)
Re place it if necessary.
C heck if there is +12V at indi cator.
Fi x if necessary, the supply electric routing between the water temperature warning indicator and
t he corresponding fuse.
C onnect the 90 ways terminal box and check the insulation and continuity on pin 9 line of the
in jection compute r.
Fi x if necessary.
If the failure is persisting after this check, refer to Instrument panel diagnostic.
Perform the operations from ” recommendations” for reparation confirma tion.
Fi x any other possible failures.
Erase the failures memoriz ed by the injection computer.
Pe rform a conformity checking by means of the CLIP tester.
Diagnostic – Failures interpretation
AF TER
REPARATION
vnx.su

Page:   < prev 1-10 ... 81-90 91-100 101-110 111-120 121-130 131-140 141-150 151-160 161-170 ... 900 next >