DACIA SOLENZA 2004 Repair Manual

Page 551 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 8
The RF remote control has only the function of blocking/ unlocking the doors. The RF remote
c ontrol with evolutionary code can use only two keys as the decoder may manage only two different
e volutionary codes.
Th e key heads have an identification number formed by eight alphanumeric characters (letters
and fi gures), beginning with letter E. In case of loosing one key, a key head and a metal insertion
will be ordered, then the resynchronisation procedure of the RF remote control of the key with the
de coder from the vehicle must be performed.
If the ve hicle is provided with RF remote control key and this one has been replaced, then
pe rfor m the “ Simple synchronised procedure “. When the vehicle has both keys with RF remote
contro l, then perform the “Specific synchronised procedure “ after the replacement of the second
key.
REMA RK:
If only one key head is replaced, usually there is no need for resynchronisation of the
other RF remote control.
If both RF re mote controls are desynchronised, one procedure of resynchronisation will
be performed w ith each remote control: perform the “Simple synchronisation procedure for
the first R F r emote control” and the “Specific synchronisation procedure” for the second
RF remote control.
Check then, the operation of doors blocking/ unlocking with both RF r emote controls.
R.F. remote control for blocking/unlocking the doors
vnx.su

Page 552 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 9
If further to the diagnostic by means of the CLIP tester, it is necessary the replacement of the
E. C.U. (computer) injection, for its dismounting, proceed as follows:
-disconnect the battery (the contact being off);
-d ismount the screw from the battery attachment clip;
-remov e the battery;
-d ismount the two attachment nuts of the injection computer and of the ECU protector;
-remov e the injection ECU protector;
-d isconnect the injection computer from the engine wiring;
-d ismount the ECU injection
For mounting, perform the dismounting operations in the reverse order.
The in jection computer is delivered not coded. It is necessary the memorising of an anti starting
code in the computer, after this has been mounted.
Proceed as follows: 1. Set the contact on, without starting the engine, for 5 seconds.
2. Ta ke off the contact; after 10 seconds, the anti starting function is activated, and the anti
starting indicator will blink rarely (one blink per second). 3. Set the contact on. The anti starting indicator must turn off after 3 seconds and the engine
can be started. In or der to disconnect the injection computer (E.C.U. injection) act upon the blocking lever (A)
of the connector in the direction of the B arrow, then the connector will be lifted in the direction of
the C arrow. In ca se the vehicle is blocked on the road further to serious damages of the anti starting system,
the “ Procedure for repairing code introduction” may be used, which allows the moving of the
vehicle to the nearest DACIA service centre for complete repairing. In order to perform this
procedur e it is necessary the CLIP tester and the specific repairing code of that vehicle.
A
B
C
Electric control unit injection replacement
vnx.su

Page 553 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 10
(For auto made before 03.07.2003)
Th
e ac oustic warning is attached on the closing plate of the upper longitudinal girder.
DISMOUNTIN G
Lift the vehicle by means of an elevator.
Disconnect the acoustic warning connector (1).
Di smount the attachment screw ( 2) of the acoustic warning on the closing plate of the left
upper longitudinal girder.
R EMOU NT I NG
Perform the dismounting operations in the reverse order. The acoustic warning must not be in
contact with the left wheel fairing.
The required tightening moment of the screw : 17 Nm ±15%.
Check the operation of the acoustic warning.
Acoustic warning
vnx.su

Page 554 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 11
REPLACEMENT OF THE ACCOUSTIC WARNING
(for auto made after 03.07.2003)
The ne w acoustic warning i s attached in t he engine c ompartment, on the left upper front
longitudinal girder.
1 2
DISMOUNTIN
G
Disconnect the battery (-) terminal.
Remove by hand the battery screen from the acoustic warnin g attaching area so that dismounting
of the screw ( 1) is permitted.
Di smount the screw ( 1) attaching the acoustic warning on the l eft upper front longitudinal
girder.
Disconnect the acoustic warning connector (2).
Carefully remove the acoustic warning
REMOU NT I NG
Perform the dismounting operations in the reverse order.
Check the operation of the acoustic warning.
REMARK !
Eac h t i me whe n di smount i ng t he ac oust i c warni ng, re pl ac e the fan-t y pe the
attachm ent screw ( 1) .
The required tightening moment of t he attachment screw is of 21 Nm + 10%.
Acoustic warning
vnx.su

Page 555 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 12
Procedures
A. E.C.U. DECODER REPLACEMENT PROCEDURE AND
ANTI STARTING CODE MEMORISING
The new E.C.U. decoder is always not coded. After its mounting on the vehicle it is necessary
that this one is memorising the anti starting code in order to be operational.
REMARK:
If only the E.C.U. decoder i s replaced, there i s no need of an i ntervention to t he
E.C.U. injection (injection computer), which will keep the old anti starting code.
AT T E N T I ON!
After the E.C.U. de coder memorised the anti starting c ode, this code cannot be erased
or replaced with another one. In order t o perform this procedure, one of the keys of t he ve hicle and the CLIP tester are
needed.
Proceed as follows:
1. Connect the CLIP tester to the diagnostic socket and to the battery (or the lighter socket)
of the vehicle. 2. Read the configuration of the old E.C.U. decoder in the following way, before dismounting
it from the vehicle:
- select the type “B41”
- enter the menu “ COMPUTER TEST” then select “ ANTI STARTING”
- access “COMMAND MODE” then “CONFIGURATIONS READING”
- note the configurations found : petrol, programming with 1 or 2 keys, ceiling delayed
light, the type of the doors’ blocking switch (CPE), etc.;
3. Return to the menu “COMPUTER TEST”
4. Remove the old E .C.U. decoder and replace it with a new one, the contact being off.
5. Enter the menu “ANTI STARTING”, then select “ STATE LIST”. If the E.C.U. decoder is
new, you must find the following states:
18G FIRST CYCLE MEMORISING………………….......………… PASSIVE
19G NOT PERFORMED KEY PROGRAMMING ………..……….. ACTIVE
19D UNBLOCKED KEY PROGRAMMING ……………….………ACTIVE
OBSERVAT ION:
If the states 19G and 19D are not “ACTIVE” this means the E.C.U. decoder has
b een already used, so it isn’t new and cannot memorise another anti starting code.
6. Access t he menu “COMMAND MODE” and then “CONFIGURATION”, where you
will c onfigure t he new E .C.U. decoder in the same way as the old one : petrol, 1 ke y, ceiling
delayed light, impulsion doors blocking switch, etc. selecting one by one these configurations,
which you’ll validate with “CLICK” on the blue button on right top of the screen.
vnx.su

Page 556 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 13
Procedures
1. Return to “COMPUTER TEST”
2. Set the contact on for 2 seconds in “ M” position, without start ing the engine. The anti
starting indicator will begin to blink rapidly.
3. Access the menu “ STATE LIST”, where the following states must exist:
9D RECEIVED KEY CODE ………………………………......…… ACTIVE
19G NOT PERFORMED KEY PROGRAMMING …………….…… PASSIVE
10. Take the c ontact off. In the menu “COMMAND MODE” select “ACTUATORS”, then
validate “ FINISHED CALIBRATION” launching the command on the blue rectangle situated
on the right top of the screen. The message “COMMAND IN PROGRESS” will appear, followed
by “ FINISHED COMMAND”. 11 . The anti starting indicator will blink rarely.
12. Return to the “STATE LIST”, which now, must be like that: 18G FIRST CYCLE MEMORISING…………………………….....…ACTIVE
19G NOT PERFORMED KEY PROGRAMMING…………….……..PASSIVE
19D UNBLOCKED KEY PROGRAMMING …………………..…… PASSIVE
13. Set the contact i n “M” position for 2-3 seconds in order t o send the code t o the E.C.U.
injection. The anti starting indicator must light for 3 seconds, then turn off.
14. Take off the contact. After 10 seconds, the anti starting indicator will blink rarely.
15. Check the engine starting with both keys, and then take the contact off.
16. Check in the menu “ STATE LIST ” if the state 10G “ANTI STARTING” is “ ACTIVE”.
Perform the synchronisation of the TRF remote control with the decoder (with 1or 2 keys).
OBSERVAT ION:
With the CLIP tester, a starting interdiction may be simulated, proceeding as follows:
- take the contact off; wait for 10 seconds, then the anti starting indicator will blink;
- in the menu, “COMMAND MODE” access “ ACTUATORS” then validate “ FORCED
PROTECTION MODE” launching the command from the blue button situated on the ri ght
topside of the screen. “COMMAND IN PROGRESS” will be displayed and then “FINISHED
COMMAND”; - in t he m enu “ STATE LIST” search for the state 10G ”ANTI START ING”, which
must be “ ACTIVE”; - set the contact on “M” position; the anti starting indicator will blink rapidly, and the
engine starting is impossible;
- remove the key from the contact and check then the engine starting with both keys, so
the procedure is finished.
vnx.su

Page 557 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 14
Procedures
RE M ARK:
For the RF remote control synchronisation, after the replacement of an E.C.U. decoder,
the sync hron is ation proced ure must be per formed taking i nto account the foll owing
situations : - fo r one RF remote control, perform the “ SIMPLE SYNCHRONISED
PROCED URE ”;
- for the second RF remote co ntrol per form the “SPE CI FI C SYNCHRONI SED
PROCED URE ”.
B. KIT REPLACEMENT PROCEDURE
(E.C.U. decoder plus 2 key he ads)
In case of one kit replacement perform the following steps:
- memorising the anti starting code by the E.C.U. decoder;
- memorising of the new anti starting code by the injection computer; it is necessary the
repairing code (found out based on the old ke y heads code) and t he CLIP tester.
Perform the actions in the following sequence:
1. Mount the metal insertions of the old keys to the new key heads.
2. Inform by phone at ”Client Voice” (phone no 0248 500 000), the vehicle chassis series and
the key heads code, written on the vehicle invoice, in order to get the repairing code.
3. Connect the CLIP tester t o the diagnostic socket and to the battery (or to the lighter
s ocket) of the vehicle. Read the configuration of the old E.C.U. decoder before dismounting it
off the vehicle, as follows:
- select vehicle type “B41”;
- enter the menu “ COMPUTER TEST” then select “ ANTI STARTING”;
- access “COMMAND MODE” then “READ CONFIGURATIONS”;
- note the configuration s : petrol/diesel, programming with 1 or 2 keys, ceiling delayed light,
the type of the doors’ blocking switch (CPE), etc.
4. Return to the menu “ANTI START ING”.
5. Dismount the old E.C.U. decoder and replace it with a new one, the contact being off.
6. Check the configuration of the new E.C.U. decoder selecting “ STAT E LIST”; here you
must find the following states: 18G FIRST KEY MEMORISING……………………………........… PASSIVE
19G NOT PERFORMED KEY PROGRAMMING ………………..... ACTIVE
19D UNBLOCKED KEY PROGRAMMING ……………………..... ACTIVE
REMARK:
If the state 19G and 19D are not “ACTIVE” this means the E.C.U. decoder isn’t a
ne w one and cannot memorise another anti starting code.
vnx.su

Page 558 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 15
Procedures
7. Set the contact i n “M” position with one of the ke ys (without start ing the engine), for
about 2 seconds and then check the following states, which must be:
9D RECEIVED KEY CODE ……………………………….....…..... ACTIVE
19G NOT PERFORMED KEY PROGRAMMING ………….........… ACTIVE
8. Set the contact with the second key (without starting t he engine) for about 2 seconds.
Check then the following states:
-case (a)- the second key belongs to the vehicle;
9D RECEIVED KEY CODE ……………………………………..… ACTIVE
19G NOT PERFORMED KEY PROGRAMMING …………….....… PASSIVE
- case (b)- t he second key doe s not belong to t he vehicle or the first ke y was used once
again;
9D RECEIVED KEY CODE ……………………………………..… PASSIVE
19G NOT PERFORMED KEY PROGRAMMING ………….....…… ACTIVE
9. The anti starting indicator blinks rapidly.
10. Take off the contact. In the menu “ COMMAND MODE” select “ACTUATORS” and
validate “ FINISHED CALIBRATION” launching the command on the blue rectangle situated
on the right top of the screen. The message “COMMAND IN PROGRESS” will appear,
followed by “ FINISHED COMMAND”. 11 . The anti starting indicator will blink rarely.
12. Return to the “STATE L IST”, which now must be as follows: 18G FIRST KEY MEMORISING…………………………….........… ACTIVE
19G NOT PERFORMED KEY PROGRAMMING……………...……PASSIVE
19D UNBLOCKED KEY PROGRAMMING ………………...…...…PASSIVE
13. In the menu “COMMAND MODE” select “ ACTUATORS”. Select the command “
FORCED PROTECTION MODE” launching the command from the blue button situated on
the ri ght topside of the screen. The display will show “COMMAND IN PROGRESS” and
then “FINISHED COMMAND”.
Return to the “STATE LIST “ and check t he state: 9GFORCED PROTECTION MODE ………………………....…… ACTIVE
14. Set the contact on “M” position. The anti starting indicator will start to blink ra pidly.
Check in the “ STATE LIST” if the state “ANTI STARTING” is “ACTIVE”.
15. In the menu “COMMAND MODE” a ccess “ACTUATORS”, then select the command
“ MANUAL CODE INTRODUCTION”. Type t he four fi gures of the repairi ng code, t hen
validate with the key “ENTER”. On the screen the message “COMMAND IN PROGRESS”
w ill appear and then “FINISHED COMMAND”.
16. Set the contact off and then set again the contact on, without starting the engine, in order
to send the new anti starting code to the injection computer. The anti starting indicator will light
for 3 seconds, and then it will turn off.
vnx.su

Page 559 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 16
Procedures
17. The procedure is finished. Check the engine starting with both keys.
REMARK:
For the RF remote control synchronisation, after the replacement of a kit, take into account
the following situations:
- for the first RF remote control, perform the “ SIMPLE SYNCHRONISED PROCEDURE”;
- for t he second RF re m ote control pe rform the “SPE CIFIC SYNCHRONISE D
PROCEDURE”. C. CODE REPAIRING INTRODUCTION PROCEDURE
The repairing code may be introduced only by means of the CLIP tester. This is possible only
if when setting the contact on, the anti starting indicator blinks rapidly, this being confirmed by the
state:
10G ANTI STARTING ……………………………………………….ACTIVE
After getting from DACIA database the repairing code (based on the vehicle chassis series
and on the code from the vehicle’s key head), perform the following operations.
1. Connect the CLIP tester to the diagnostic socket and to the battery (or to the lighter
socket) of the vehicle.
2. The anti start up indicator must blink slowly , the contact being taken off.
3. Set the contact in “M” position. The indicator must blink rapidly.
4. Select vehicle type “B41”;
5. Select the menu “ COMPUTER TEST” then select “ ANTI STARTING”.
6. In the menu “STAT E LIST” find the state 10G “ANTI STARTING” which must be
“ACTIVE”. 7. Access “COMMAND MODE” then select “ACTUATORS”.
8. Select the command “ MANUAL CODE INTRODUCTION” where you will write the
repairi ng c ode (form ed of 4 fi gures), then validate it with t he ke y “ ENTER”. The message
“COMMAND IN PROGRESS” will be displayed followed by the message “FINISHED
COMMAND”. 9. Now the procedure is finished and you may start the vehicle engine.
AT T E N T I ON!
Yo u may perform three attempts of introducing the repairing code; if after the third
essay the code is not yet valid, wait for 15 minutes, take off the contact and then set it
again, then other three attempts may be performed.
REMARK:
This procedure does not decode the injection computer, but is only allowing the start
of the vehicle’s engine. After 10 minutes have passed from the first introduction of the
r epairing code or after the disconnection of the battery, the vehicle’s engine cannot be
s tarted unless a new repairing code is introduced.
vnx.su

Page 560 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 17
Procedures
D. SIMPLE SYNCHRONISED PROCEDURE
This procedure allows the synchronisation of a RF remote control with E.C.U. decoder and
is to be applied in the following situations: -the RF remote control c ode is no longer in the range of the E .C.U. decoder reception,
because of blind consecutive pushing over a 1000 time on the RF remote control button.;
- the replacement of the E .C.U. decoder with a new one;
- the replacement of the RF remote control if the E.C.U. decoder is new (E.C.U. decoder
replacement plus a RF key.);
The following operations will be performed: -take off the contact;
- push and maintain like that for about 5 seconds, the doors locking switch located on the
dashboard ; the doors actuators are performing a closing/opening course;
- during the next 10 seconds, confirmed by the permanent lightening of the anti starting
system indicator, push twice the RF remote control button; the doors actuators are performing a
closing/opening course;
-the procedure of synchronisation is finished; check the doors blocking/ unlocking by
pushing the RF remote control.
OBSERVAT ION:
During those 10 seconds you can visualise by means of the CLIP tester t he state 17G
“PROGRAMMING OR TIR/TRF RESYNCHRONISATION” which must be ACTIVE.
E. SPECIFIC SYNCHRONISED PROCEDURE
This procedure is used for the synchronisation of the second RF key with E.C.U. decoder
and will be performed as follows:
-connect the CLIP tester to the diagnostic socket and the battery (or the lighter socket)
of the vehicle;
- select the vehicle type “B41”;
- select the menu “ COMPUTERS TEST” then “ ANTI STARTING”;
- enter the menu “COMMAND MODE” and select “CONFIGURATION”;
- validate the command “ PROGRAMMI NG THE SECOND TIR / TRF KEY” launching
the command from the blue button situated on the right top of the screen; the doors actuators are
performing a closing/opening course. - during the next 10 seconds, confirmed by the permanent lightening of the anti starting
system, push twice t he RF remote control button; the doors will block and then unlock and the
anti starting indicator will turn off. The second remote control is now synchronised. Check the
blocking/ unlocking by pushing the RF remote control.
vnx.su

Page:   < prev 1-10 ... 511-520 521-530 531-540 541-550 551-560 561-570 571-580 581-590 591-600 ... 900 next >