air conditioning FORD MUSTANG 2003 User Guide

Page 3076 of 4378

to plot a vertical line for ambient temperature and a
horizontal line for A/C clutch OFF time in seconds.
z Is the intersection of the two lines above the upper
limit? DISCHARGE and RECOVER
the system to remove
excessive moisture or
refrigerant oil. REFER to
Air Conditioning (A/C) System
Recovery, Evacuation and
Charging . TEST the system
for normal operation.
No
GO to E7 .
E6 CHECK FOR A HIGH SUCTION PRESSURE
z
Refer to the data plot used to evaluate the system low
pressure performance in Step E3.
z Is the intersection of the two lines above the upper
limit? Yes
REMOVE the A/C evaporator
core orifice to repair missing or
damaged (leaking) O-
ring
seals. REFER to Section 412 -
03 . TEST the system for
normal operation.
No
INSTALL a new A/C cycling
switch when the intersection of
the two lines is below the
lower limit. REFER to Section 412 - 03 . TEST the system for
normal operation. E7 CHECK THE AMBIENT TEMPERATURE
z
Refer to the data plot used to evaluate the system A/C
clutch OFF time in Step E5.
z Is the ambient temperature above 26°C (80°F)? Yes
This is normal operation for
the refrigerant system in high
humidity conditions.
No
DISCHARGE and RECOVER
the system to correct an
overcharge condition. REFER
to
Air Conditioning (A/C) System Recovery, Evacuation
and Charging . TEST the
system for normal operation. E8 CHECK FOR A HIGH DISCHARGE PRESSURE
z
Refer to the data plot used to evaluate the system high
pressure performance in Step E2.
z Is the intersection of the two lines above the upper
limit? Yes
GO to
E9 .
No
GO to E11 .
E9 CHECK FOR A NORMAL LOW PRESSURE
z
Use the recorded data from the refrigerant system tests
to plot a vertical line for ambient temperature and a
horizontal line for compressor suction (low) pressure. Yes
REFER to
Section 303 - 03A or
Section 303 - 03B . to diagnose
the engine cooling system.
TEST the system for normal
operation. Klj . 27 ba
412003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3078 of 4378

z
Is the intersection of the two lines above the upper
limit? E13 CHECK FOR A NORMAL A/C CLUTCH OFF TIME
z
Use the recorded data from the refrigerant system tests
to plot a vertical line for ambient temperature and a
horizontal line for A/C clutch OFF time in seconds.
z Is the intersection of the two lines within the upper
and lower limits? Yes
INSPECT the A/C evaporator
core due to a low or restricted
airflow. TEST the system for
normal operation.
No
GO to
E14 .
E14 CHECK FOR A LONG A/C CLUTCH OFF TIME
z
Refer to the data plot used to evaluate the system A/C
clutch OFF time performance in Step E13.
z Is the intersection of the two lines above the upper
limit? Yes
INSTALL a new A/C
condenser core due to a
partially restricted or plugged
condition. REFER to
Section 412 - 03 . TEST the system for
normal operation.
No
EVACUATE and RECHARGE
the system when the
intersection of the two lines is
below the lower limit. REFER
to Air Conditioning (A/C) System Recovery, Evacuation
and Charging . TEST the
system for normal operation. E15 CHECK FOR A MISSING A/C EVAPORATOR CORE
ORIFICE z
Remove the A/C evaporator core orifice tube. Refer to
Section 412 - 03 .
z Is the A/C evaporator core orifice missing? Yes
INSTALL a new A/C
evaporator core orifice.
REFER to
Section 412 - 03 .
TEST the system for normal
operation.
No Klj . 29 ba
412003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3088 of 4378

A/C Evaporator/Condenser Core—
On-Vehicle Leak Test
1. Discharge and recover the refrigerant. For additional information, refer to Air Conditioning (A/C) System Recovery, Evacuation and Charging in this section.
2. NOTE: DO NOT leak test an A/C evaporator core with the suction accumulator/drier (19C836)
attached to the core tubes.
Disconnect the suspect A/C evaporator core or A/C condenser core from the A/C system. For
additional information, refer to Section 412 - 03 .
3. Clean the spring lock couplings. For additional information, refer to Spring Lock Coupling in this
section.
4. Connect the appropriate test fittings from the A/C Test Fitting Set to the evaporator or condenser tube connections.
5. NOTE: The automatic shut- off valves on some gauge set hoses do not open when connected to
the test fittings. If available, use hoses without shut- off valves. If hoses with shut-off valves are
used, make sure the valve opens when attached to the test fittings or install an adapter which
will activate the valve. The test is not valid if the shut- off valve does not open.
Connect the red and blue hoses from the manifold gauge set to the test fittings on the A/C
evaporator core or A/C condenser core. Connect the yellow hose to a known good vacuum
pump.
6. Open both gauge set valves and start the vacuum pump. Allow the vacuum pump to operate for a minimum of 45 minutes after the gauge set low pressure gauge indicates 101 kPa (30 in- Hg).
The 45- minute evacuation is necessary to remove any refrigerant from oil left in the A/C
evaporator core or A/C condenser core. If the refrigerant is not completely removed from the oil,
outgassing will degrade the vacuum and appear as a refrigerant leak.
7. If the low pressure gauge reading will not drop to 101 kPa (30 in- Hg) when the valves on the
gauge and manifold set are open and the vacuum pump is operating, close the gauge set
valves and observe the low pressure gauge. If the pressure rises rapidly to zero, a large leak is
indicated. Recheck the test fitting connections and gauge set connections before installing a
new A/C evaporator core or A/C condenser core.
8. After evacuating for 45 minutes, close the gauge set valves and stop the vacuum pump. Observe the low pressure gauge; it should remain at the 101 kPa (30 in- Hg) mark.
z If the low pressure gauge reading rises 34 or more kPa (10 or more in- Hg) of vacuum
from the 101 kPa (30 in- Hg) position in 10 minutes, a leak is indicated.
z If a very small leak is suspected, wait 30 minutes and observe the vacuum gauge.
z If a small amount of vacuum is lost, operate the vacuum pump with gauge valves open
for an additional 30 minutes to remove any remaining refrigerant from the oil in the A/C Klj . 39 ba
412003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3089 of 4378

evaporator core or A/C condenser core. Then recheck for loss of vacuum.
z If a very small leak is suspected, allow the system to sit overnight with vacuum applied
and check for vacuum loss.
9. If the A/C evaporator core or A/C condenser core does leak, as verified by the above procedure, install a new A/C evaporator core or A/C condenser core. For additional information, refer to
Section 412 - 03 .
A/C Compressor— External Leak Test
1. Install the A/C pressure test adapter on the rear head of the A/C compressor using the existing manifold retaining bolt.
2. Connect the high and low pressure lines of a manifold gauge set or a refrigerant recovery/recycling station such as the R- 134a A/C Service Center to the corresponding fittings
on the A/C pressure test adapter.
3. Attach the center hose of the manifold gauge set to a refrigerant container standing in an upright position.
4. Hand- rotate the compressor shaft 10 complete revolutions to distribute the oil inside the A/C
compressor.
5. Open the low pressure gauge valve, the high pressure gauge valve and the valve on the refrigerant container to allow the refrigerant vapor to flow into the A/C compressor.
6. Using the Refrigerant Leak Detector, check for leaks at the compressor shaft seal and the compressor center seal.
7. If a shaft seal leak is found, install a new shaft seal. For additional information, refer to Section 412 - 03 . If an external leak is found at the center joint of the A/C compressor, install a new A/C
compressor.
8. When the leak test is complete, recover the refrigerant. For additional information, refer to Air Conditioning (A/C) System Recovery, Evacuation and Charging in this section. Klj . 40 ba
412003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3091 of 4378

GENERAL PROCEDURES
Air Conditioning (A/C) System Check —
Retail Procedure
NOTE: This Retail Procedure is not eligible for claiming on Ford paid repairs (warranty and ESP).
NOTE: The engine should be run at idle for 10 minutes with the air conditioning on and set to MAX A/C
before carrying out this retail procedure.
NOTE: Read and follow all of the Warnings, Cautions and Notes at the beginning of this section before
continuing.
1. Visual inspection
Open the hood and visually inspect the heating and air conditioning systems for the following:
zCoolant reservoir for correct coolant level
z Heater hoses for deterioration or loose connections
z Radiator and condenser for debris or damaged fins restricting airflow, loose mounting or
connections
z Accessory drive belt(s) and cooling fan(s) for wear or physical damage
z Refrigerant lines and connections for physical damage or loose connections
z Compressor for physical damage or loose connections
z Suction accumulator/drier for physical damage or loose connections
z Wiring and connectors for excessive wear, loose or damaged connections, or incorrect
routing
2. A/C refrigerant analysis
zCarry out air conditioning refrigerant analysis. For additional information, refer to
Refrigerant Identification Testing in this section.
z If the refrigerant fails the analysis, discontinue diagnosis and make recommendations for
repairs.
z If the refrigerant passes the analysis, carry out the air conditioning system check.
3. Air conditioning system check
zConnect manifold gauge set or charging station with gauges to refrigerant system.
z With the vehicle in park, parking brake set, thermometer installed in center panel vent,
and air conditioning system on and set to MAX A/C, start the engine.
z Record air refrigerant system pressures while running the engine at 1,500 rpm and allow
engine to return to idle.
z Operate the blower motor in all control positions and check for correct blower speed
changes.
z With the blower motor on HI, operate air discharge mode selector in all positions and
check for correct airflow in each position.
z Operate the temperature blend selector in all positions and check for correct change in
discharge temperature. Check the air discharge temperature with the selector in the
coolest position and the air conditioning on and set to MAX A/C to determine if the air
discharge temperature is acceptable for the current ambient air temperature.
z Carry out the EATC self- test (if applicable).
If the refrigerant system pressures were low, carry out the refrigerant system leak test.
SECTION 412-
00: Climate Control System - General Information 2003 Mustang Workshop Manual Klj . 1 ba
22003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3102 of 4378

GENERAL PROCEDURES
Air Conditioning Line (Peanut) Fitting
Disconnect
1. CAUTION: Support the female fitting with a wrench to prevent the tubes from
twisting.
Remove the nut from the peanut fitting.
2. Pull the peanut fitting apart.
3. CAUTION: Do not use metal tools to remove the O- ring seal. They can cause axial
scratches across the O- ring seal groove, resulting in refrigerant leaks.
Remove the O- ring seal with a non- metallic tool.
SECTION 412-
00: Climate Control System - General Information 2003 Mustang Workshop Manual Klj . 1 ba
32003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3109 of 4378

GENERAL PROCEDURES
Air Conditioning (A/C) Clutch Air Gap Adjustment
1. Check the A/C clutch air gap at three equally- spaced places between the A/C clutch hub (2884)
and the A/C clutch pulley (2E884).
2. Remove the A/C clutch. Add or remove spacers between the A/C clutch and the compressor shaft until clearance is within specification. For additional information, refer to Section 412 - 03 .
SECTION 412-
00: Climate Control System - General Information 2003 Mustang Workshop Manual Klj . 1 ba
12003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3113 of 4378

GENERAL PROCEDURES
Electronic Leak Detection
CAUTION: Good ventilation is necessary in the area where electronic A/C leak testing is to
be carried out. If the surrounding air is contaminated with refrigerant gas, the leak detector will
indicate this gas all the time. Odors from other chemicals such as anti- freeze, diesel fuel, disc
brake cleaner, or other cleaning solvents can cause the same problem. A fan, even in a well-
ventilated area, is very helpful in removing small traces of contamination from the air that
might affect the leak detector.
1. NOTE: The system pressure should be between 413- 551 kPa (60-80 psi) at 24°C (75°F) with
the engine off.
Leak test the refrigerant system using the Refrigerant Leak Detector. Follow the instructions
included with the leak detector for handling and operation techniques.
2. If a leak is found, discharge and recover the refrigerant. For additional information, refer to Air Conditioning (A/C) System Recovery, Evacuation and Charging in this section.
z Repair the system.
z Test the system for normal operation.
SECTION 412-
00: Climate Control System - General Information 2003 Mustang Workshop Manual Special Tool(s)
H10PM Refrigerant Leak
Detector With Battery
216-
00001 or equivalent Klj . 1 ba
22003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3117 of 4378

GENERAL PROCEDURES
Air Conditioning (A/C) System Flushing
WARNING: Use extreme care and observe all safety and service precautions related to the
use of refrigerants.
WARNING: Due to refrigerant hazards, always wear safety goggles and non- penetrable
gloves when working on or flushing A/C systems.
CAUTION: An A/C refrigerant analyzer must be used before the recovery of any vehicle's
A/C refrigerant. Failure to do so puts the shop's bulk refrigerant at risk of contamination. If the
vehicle's A/C refrigerant is contaminated, refer the customer to the service facility that carried
out the last A/C service. If the customer wishes to pay the additional cost, use the A/C recovery
equipment that is designated for recovering contaminated A/C refrigerant. All contaminated
A/C refrigerant must be disposed of as hazardous waste. For all equipment, follow the
equipment manufacturer's procedures and instructions.
CAUTION: Suction accumulator/drier, muffler, hoses, thermal expansion valve, and fixed
orifice tube should be removed when flushing the A/C system. Internal plumbing of these
devices makes it impossible to correctly remove any residual- flushing agent. Except for the
hoses, these components are typically discarded after A/C system contamination. Hoses can
normally be reused unless they are clogged with foreign material. The 3.785 liters (1 gallon) of
A/C Systems Flushing Solvent F4AZ-19579- A and FL1-A filter used in A/C Flush and Purge
Machine 219- 00022 are intended for use on one vehicle only. They may be used to flush both
the A/C condenser core and the A/C evaporator core on an individual vehicle, but under no
circumstances should they be used on more than one vehicle.
1. NOTE: Prior to using the A/C Flush and Purge Machine 219- 00022 for the first time, review the
operating instructions.
NOTE: Only the A/C Flush and Purge Machine kit 219- 00023, which includes A/C Flush and
Purge Machine 219- 00022, A/C Flush and Purge Fitting Kit 219- 00024, and the Ford Part
number F4AZ-19579- A A/C Systems Flushing Solvent, is approved for use on Ford vehicles. No
other flushing device or solvent is approved for flushing heat exchangers. Use of any other
flusher or solvent may cause damage to the A/C system and the flushing unit.
SECTION 412-
00: Climate Control System - General Information 2003 Mustang Workshop Manual Special Tool(s)
A/C Flush and Purge Machine
219-
00022 (part of 219- 00023)
or equivalent A/C Flush and Purge Fitting Kit
219-
00024 (part of 219- 00023)
or equivalent Klj . 1 ba
32003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3120 of 4378

GENERAL PROCEDURES
Air Conditioning (A/C) System Recovery, Evacuation and
Charging
Refrigerant System Recovery
NOTE:
Ford Motor Company recommends use of an A/C service center to carry out recovery,
evacuation, and charging of the refrigerant system. If an A/C service center is not available, refrigerant
system recovery, evacuation, and charging may be accomplished using a separate recovery station,
vacuum pump, charging cylinder, and manifold gauge set.
1. Prior to recovering the refrigerant system, you must verify the purity of the refrigerant. For additional information, refer to Refrigerant Identification Testing in this section.
2. NOTE: Some R- 134a service centers require the use of an A/C manifold gauge set. For
additional information, refer to Manifold Gauge Set Connection in this section.
SECTION 412-
00: Climate Control System - General Information 2003 Mustang Workshop Manual Special Tool(s)
R-
134a A/C Refrigerant Center
176- 00002 or equivalent R-
134a A/C Refrigerant Center
023- 00153 or equivalent R-
134a Manifold Gauge Set
176- R032A or equivalent 1.2 CFM Vacuum Pump
023-
00162 or equivalent 4.0 CFM Vacuum Pump
023-
00163 or equivalent Klj . 1 ba
32003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...