The 3.8L cooling system components include the:
zblock heater
z engine coolant temperature (ECT) sensor
z fan blade, fan motor and fan shroud assembly
z radiator
z radiator cap
z radiator draincock
z coolant pump
z coolant thermostat
z oil filter adapter
z radiator overflow hose
z coolant expansion tank
z upper radiator hose
z lower radiator hose
The fan blade draws air through the radiator to help cool the engine coolant.
The fan motor:
zoperates only when the ignition switch is in the RUN position.
z will not operate with the switch in the OFF position.
The engine coolant:
zflows through the radiator tubes and is cooled by passing air over the cooling fins.
z is then circulated from the radiator outlet tank through the coolant pump and into the cylinder
block to complete the circuit.
A closed coolant thermostat returns the engine coolant to the coolant pump. An open coolant
thermostat allows the engine coolant to flow to the radiator.
CAUTION: Engine coolant provides freeze protection, boil protection, cooling efficiency,
and corrosion protection to the engine and cooling components. In order to obtain these
protections, the engine coolant must be maintained at the correct concentration and fluid level
in the degas bottle (4.6L) or coolant expansion tank (3.8L).
When adding engine coolant, use a 50/50 mixture of engine coolant and deionized water.
To maintain the integrity of the coolant and the cooling system:
zNOTE: The addition of Motorcraft Cooling System Stop Leak Pellets, VC-6, darkens Motorcraft
Premium Gold Engine Coolant from yellow to golden tan.
Add Motorcraft Premium Gold Engine Coolant VC-7- A (in Oregon VC-7-B) or equivalent
meeting Ford specification WSS- M97B51-A1 (yellow color). Use the same coolant that is
present in the cooling system. Do not mix coolant types.
z Do not add/mix orange-colored Motorcraft Speciality Orange Engine Coolant VC- 2 or equivalent Klj . 2 ba
32003 Mustang Workshop Manual
17. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_4464/S3B~us~en~ ...

Page 1854 of 4378

GENERAL PROCEDURES
Cooling System Draining, Filling and Bleeding
Draining
WARNING: Never remove the pressure relief cap while the engine is operating or when the
cooling system is hot. Failure to follow these instructions can result in damage to the cooling
system or engine or personal injury. To avoid having scalding hot coolant or steam blow out of
the degas bottle when removing the pressure relief cap, wait until the engine is cooled, then
wrap a thick cloth around the pressure relief cap and turn it slowly. Step back while the
pressure is released from the cooling system. When you are sure all the pressure has been
released, turn and remove the pressure relief cap (still with a cloth).
CAUTION: The coolant must be recovered in a suitable, clean container for reuse. If the
coolant is contaminated, it must be recycled or disposed of correctly.
NOTE: Less than 80% of coolant capacity can be recovered with the engine in the vehicle. Dirty, rusty
or contaminated coolant should be drained and filled with new coolant.
1. Release the pressure in the cooling system by slowly turning the pressure relief cap one half turn counterclockwise or the radiator cap counterclockwise to the first stop. When the pressure
is released, remove the pressure relief cap/radiator cap.
2. Place a suitable container below the radiator draincock. If equipped, disconnect the coolant return hose at the fluid cooler. Open the draincock and drain the engine coolant.
zClose the radiator draincock.
Filling — 3.8L
CAUTION: Vehicle cooling systems are filled with Motorcraft Premium Gold Engine
Coolant VC -7-A (in Oregon VC -7-B) or equivalent meeting Ford specification WSS- M97B51-A1
(yellow color). Always fill the cooling system with the same coolant that is present in the
system. Do not mix coolant types.
CAUTION: Engine coolant provides freeze protection, boil protection, cooling efficiency,
and corrosion protection to the engine and cooling components. In order to obtain these
protections, the engine coolant must be maintained at the correct concentration and fluid level
in the degas bottle.
When adding engine coolant, use a 50/50 mixture of engine coolant and deionized water. SECTION 303-
03A: Engine Cooling 2003 Mustang Workshop Manual Material
Item Specification
Motorcraft Premium Gold
Engine Coolant
VC
-7-A (in Oregon VC-7- B)
(yellow color) WSS-
M97B51-
A1 Klj . 1 ba
72003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_4464/S3B~us~en~ ...

Page 1856 of 4378

CAUTION: Vehicle cooling systems are filled with Motorcraft Premium Gold Engine
Coolant VC -7-A (in Oregon VC -7-B) or equivalent meeting Ford specification WSS- M97B51-A1
(yellow color). Always fill the cooling system with the same coolant that is present in the
system. Do not mix coolant types.
CAUTION: Engine coolant provides freeze protection, boil protection, cooling efficiency,
and corrosion protection to the engine and cooling components. In order to obtain these
protections, the engine coolant must be maintained at the correct concentration and fluid level
in the degas bottle.
When adding engine coolant, use a 50/50 mixture of engine coolant and deionized water.
To maintain the integrity of the coolant and the cooling system:
zAdd Motorcraft Premium Gold Engine Coolant VC -7-A (in Oregon VC -7-B) or equivalent
meeting Ford specification WSS- M97B51-A1 (yellow color). Use the same coolant that
was drained from the cooling system. Do not mix coolant types.
z Do not add/mix orange- colored Motorcraft Speciality Orange Engine Coolant VC- 2 or
equivalent meeting Ford specification WSS- M97B44-D. Mixing coolants may degrade the
coolant's corrosion protection.
z Do not add alcohol, methanol, or brine, or any engine coolants mixed with alcohol or
methanol antifreeze. These can cause engine damage from overheating or freezing.
z Do not mix with recycled coolant unless it meets the requirements of Ford specification
WSS- M97B51- A1. Not all coolant recycling processes meet these Ford specifications.
Use of such coolants can harm the engine and cooling system components.
NOTE: The addition of Motorcraft Cooling System Stop Leak Pellets, VC- 6, darkens Motorcraft
Premium Gold Engine Coolant from yellow to golden tan.
1. Remove the thermostat. For additional information, refer to Thermostat — 4.6L(2V) in this
section.
2. Disconnect the heater core coolant supply hose from the fitting at the rear of the manifold.
3. Add the coolant/water mixture through the thermostat opening until coolant appears at the heater core coolant supply outlet fitting at the rear of the manifold.
4. Install the heater hose, using an appropriately sized worm style clamp in place of the constant tension clamp.
5. Reinstall the thermostat gasket (O- ring) and the thermostat. For additional information, refer to
Thermostat — 4.6L(2V) in this section.
6. Add the correct engine coolant mixture to the degas bottle until the coolant level is between the Klj . 3 ba
72003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_4464/S3B~us~en~ ...

Page 1857 of 4378

"COOLANT FILL LEVEL" marks and replace the pressure cap.
7. Select the maximum cool temperature setting.
8. Run the engine until it reaches operating temperature.
9. CAUTION: If the engine coolant temperature gauge does not move, the engine
coolant level in the engine is low and must be filled. Stop the engine, allow it to cool and
fill the cooling system.
Add the correct engine coolant mixture to the degas bottle until the coolant level is between the
"COOLANT FILL LEVEL" marks.
10. Repeat the two previous steps until the engine coolant mixture is between the "COOLANT FILL LEVEL" marks on the degas bottle. Turn off the engine and allow it to cool.
11. Check the freeze protection of the engine coolant mixture with the Battery/Anti- freeze Tester
014- R1060 or equivalent. Adjust freezing point range if necessary.
Filling — Cobra
CAUTION: Vehicle cooling systems are filled with Motorcraft Premium Gold Engine
Coolant VC -7-A (in Oregon VC -7-B) or equivalent meeting Ford specification WSS- M97B51-A1
(yellow color). Always fill the cooling system with the same coolant that is present in the
system. Do not mix coolant types.
CAUTION: Engine coolant provides freeze protection, boil protection, cooling efficiency,
and corrosion protection to the engine and cooling components. In order to obtain these
protections, the engine coolant must be maintained at the correct concentration and fluid level
in the degas bottle.
When adding engine coolant, use a 50/50 mixture of engine coolant and deionized water.
To maintain the integrity of the coolant and the cooling system:
zAdd Motorcraft Premium Gold Engine Coolant VC -7-A (in Oregon VC -7-B) or equivalent
meeting Ford specification WSS- M97B51-A1 (yellow color). Use the same coolant that
was drained from the cooling system. Do not mix coolant types.
z Do not add/mix orange- colored Motorcraft Speciality Orange Engine Coolant VC- 2 or
equivalent meeting Ford specification WSS- M97B44-D. Mixing coolants may degrade the
coolant's corrosion protection.
z Do not add alcohol, methanol, or brine, or any engine coolants mixed with alcohol or
methanol antifreeze. These can cause engine damage from overheating or freezing.
z Do not mix with recycled coolant unless it meets the requirements of Ford specification
WSS- M97B51- A1. Not all coolant recycling processes meet these Ford specifications.
Use of such coolants can harm the engine and cooling system components.
NOTE: The addition of Motorcraft Cooling System Stop Leak Pellets, VC- 6, darkens Motorcraft
Premium Gold Engine Coolant from yellow to golden tan.
1. Check all hose clamps for correct tightness. Make sure the radiator draincock is closed.
2. Place the heater temperature selector in maximum cool position. Klj . 4 ba
72003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_4464/S3B~us~en~ ...

Page 1858 of 4378

3. Remove the pressure cap from the cooling system reservoir and the fill plug from the engine
crossover tube.
4. CAUTION: Do not fill the cooling system through the reservoir only. Coolant will not
enter the engine. Only the reservoir and the radiator will be filled and engine overheating
will occur.
Add coolant into the fill neck on the engine crossover tube until coolant reaches the top of the fill
neck on the cooling system reservoir.
5. Install the cooling system pressure cap on the reservoir.
6. Continue to fill the cooling system at the engine crossover fill neck until full.
7. Install the engine crossover tube fill plug.
8. WARNING: To avoid the possibility of personal injury or damage to the vehicle, do
not operate the engine with the hood open until the fan has been first examined for
possible cracks and separation.
CAUTION: If the engine temperature gauge does not move, coolant level is low in
the engine and must be filled. Stop the engine, allow to cool, and fill the cooling system
as outlined.
Run the engine until the thermostat opens (coolant flowing through the radiator lower hose
becomes hot).
9. Stop the engine and allow to cool.
10. Add coolant to the engine crossover tube fill neck until the cooling system is full.
11. Install the fill plug.
12. Repeat the fill procedure if necessary.
Filling — Mach I
CAUTION: Vehicle cooling systems are filled with Motorcraft Premium Gold Engine
Coolant VC -7-A (in Oregon VC -7-B) or equivalent meeting Ford specification WSS- M97B51-A1
(yellow color). Always fill the cooling system with the same coolant that is present in the
system. Do not mix coolant types.
CAUTION: Engine coolant provides freeze protection, boil protection, cooling efficiency,
and corrosion protection to the engine and cooling components. In order to obtain these
protections, the engine coolant must be maintained at the correct concentration and fluid level
in the degas bottle.
When adding engine coolant, use a 50/50 mixture of engine coolant and deionized water.
To maintain the integrity of the coolant and the cooling system:
zAdd Motorcraft Premium Gold Engine Coolant VC -7-A (in Oregon VC -7-B) or equivalent
meeting Ford specification WSS- M97B51-A1 (yellow color). Use the same coolant that Klj . 5 ba
72003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_4464/S3B~us~en~ ...

Page 1898 of 4378

DESCRIPTION AND OPERATION
Supercharger Cooling
CAUTION: Some vehicle cooling systems are filled with Motorcraft Premium Engine
Coolant VC -4-A (in Oregon VC- 5, in Canada CXC- 10) or equivalent meeting Ford specification
ESE- M97B44- A (green color). Others are filled with Motorcraft Premium Gold Engine Coolant
VC -7-A or equivalent meeting Ford specification WSS- M97B51-A1 (yellow color). Always fill the
cooling system with the same coolant that is present in the system. Do not mix coolant types.
NOTE: The addition of Motorcraft Cooling System Stop Leak Pellets, VC- 6, darkens Motorcraft
Premium Gold Engine Coolant from yellow to golden tan.
NOTE: The air that is produced from the supercharger is cooled by the intercooler.
Walter C. Avrea, the owner of patents 3,601,181 and RE 27,965, has granted Ford Motor Company
rights with respect to cooling systems covered by these patents.
The cooling system components include the:
zintercooler
z intercooler radiator (8K226)
z pressure relief cap
z degas bottle
z electric water pump (8501)
The degas bottle:
zprovides a location for system fill.
z contains coolant expansion and system pressurization.
z provides air separation during operation.
z replenishes the intercooler coolant to the system.
The intercooler coolant flows:
zfrom the intercooler to the degas bottle.
z from the degas bottle to the water pump.
z from the water pump to the intercooler radiator.
z from the intercooler radiator to the intercooler.
Engine coolant provides freeze protection, boil protection, cooling efficiency and corrosion protection to
the engine and cooling components. In order to obtain these protections, the engine coolant must be
maintained at the correct concentration and fluid level in the degas bottle.
When adding engine coolant, use a 50/50 mixture of engine coolant and clean, drinkable water.
To maintain the integrity of the coolant and the cooling system: SECTION 303-
03B: Supercharger Cooling 2003 Mustang Workshop Manual Klj . 1 ba
22003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_4464/S3B~us~en~ ...

Page 1907 of 4378

GENERAL PROCEDURES
Supercharger Cooling System Draining, Filling and
Bleeding
Draining
WARNING: Never remove the pressure relief cap while the engine is operating or when the
cooling system is hot. Failure to follow these instructions can result in damage to the cooling
system or engine or personal injury. To avoid having scalding hot coolant or steam blow out of
the degas bottle when removing the pressure relief cap, wait until the engine has cooled, then
wrap a thick cloth around the pressure relief cap and turn it slowly. Step back while the
pressure is released from the cooling system. When certain all the pressure has been released,
(still with a cloth) turn and remove the pressure relief cap.
CAUTION: The coolant must be recovered in a suitable, clean container for reuse. If the
coolant is contaminated, it must be recycled or disposed of correctly and replaced.
CAUTION: Some vehicle cooling systems are filled with Motorcraft Premium Engine
Coolant VC -4-A (in Oregon VC- 5, in Canada CXC- 10) or equivalent meeting Ford specification
ESE- M97B44- A (green color). Others are filled with Motorcraft Premium Gold Engine Coolant
VC -7-A or equivalent meeting Ford specification WSS- M97B51-A1 (yellow color). Always fill the
cooling system with the same coolant that is present in the system. Do not mix coolant types.
NOTE: The addition of Motorcraft Cooling System Stop Leak Pellets, VC- 6, darkens Motorcraft
Premium Gold Engine Coolant from yellow to golden tan.
NOTE: Less than 80% of coolant capacity can be recovered with the engine in the vehicle. Dirty, rusty
or contaminated coolant requires replacement.
1. Raise and support the vehicle. For additional information, refer to Section 100 - 02 .
2. Remove the lower hose from the intercooler radiator and allow the coolant to drain.
Filling and Bleeding
CAUTION: Engine coolant provides freeze protection, boil protection, cooling efficiency
and corrosion protection to the engine and cooling components. In order to obtain these
protections, the engine coolant must be maintained at the correct concentration and fluid level
in the degas bottle.
CAUTION: Some vehicle cooling systems are filled with Motorcraft Premium Engine
Coolant VC -4-A (in Oregon VC- 5, in Canada CXC- 10) or equivalent meeting Ford specification
ESE- M97B44- A (green color). Others are filled with Motorcraft Premium Gold Engine Coolant
VC -7-A or equivalent meeting Ford specification WSS- M97B51-A1 (yellow color). Always fill the
cooling system with the same coolant that is present in the system. Do not mix coolant types.
NOTE: The addition of Motorcraft Cooling System Stop Leak Pellets, VC- 6, darkens Motorcraft
Premium Gold Engine Coolant from yellow to golden tan.
NOTE: When adding engine coolant, use a 50/50 mixture of engine coolant and clean, drinkable
water. SECTION 303-
03B: Supercharger Cooling 2003 Mustang Workshop Manual Klj . 1 ba
22003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_4464/S3B~us~en~ ...

Page 3121 of 4378

Connect an R-
134a A/C service center to the low- and high-pressure service gauge port valves.
3. Recover the refrigerant from the system following the operating instructions provided by the equipment manufacturer.
4. Once the service center has recovered the vehicle A/C system refrigerant, close the service center inlet valve (if equipped). Then switch off the power supply.
5. Allow the vehicle A/C system to remain closed for about two minutes. Observe the system vacuum level as shown on the gauge. If the vacuum does not decrease, disconnect the
refrigerant center hose(s).
6. If the system vacuum does decrease, repeat Steps 2 through 5 until the vacuum level remains stable for two minutes.
7. Carry out the required repairs.
Refrigerant System Evacuation
NOTE: Ford Motor Company recommends use of an A/C service center to carry out recovery,
evacuation, and charging of the refrigerant system. If an A/C service center is not available, refrigerant
system recovery, evacuation, and charging may be accomplished using a separate recovery station,
vacuum pump, charging cylinder, and manifold gauge set.
1. Connect an R- 134a service center to the low- and high-pressure service gauge port valves.
2. Evacuate the system until the low- pressure gauge reads at least 99.4 kPa (29.5 in- Hg) of
vacuum and as close to 101.1 kPa (30 in- Hg) as possible. Continue to operate the vacuum
pump for a minimum of 45 minutes.
3. Turn off the vacuum pump. Observe the low- pressure gauge for five minutes to make sure that
the system vacuum is held. If vacuum is not held for five minutes, leak test the system, service
the leak, and evacuate the system again.
Refrigerant System Charging
NOTE: Ford Motor Company recommends use of an A/C service center to carry out recovery,
evacuation, and charging of the refrigerant system. If an A/C service center is not available, refrigerant
system recovery, evacuation, and charging may be accomplished using a separate recovery station,
vacuum pump, charging cylinder, and manifold gauge set.
1. Correctly oil match the system to verify that the correct amount of refrigerant oil is present in the system. For additional information, refer to Refrigerant Oil Adding in this section.
2. Charge the system with the specified amounts of refrigerant oil and refrigerant.
3. When no more refrigerant is being drawn into the system, start the engine and select MAX A/C operation. Adjust the blower motor speed to the maximum and allow the remaining refrigerant to
be drawn into the system. Continue to add refrigerant into the system until the specified weight
of R- 134a has been added. Close the charging cylinder valve and allow the system to pull any
remaining refrigerant from the hose. When the low- pressure drops to approximately 207 kPa
(30 psi), close the charging hose valve. Klj . 2 ba
32003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3124 of 4378

6. Correctly oil match the system. For additional information, refer to
Refrigerant Oil Adding in this
section.
7. Evacuate and charge the system. For additional information, refer to Air Conditioning (A/C) System Recovery, Evacuation and Charging in this section.
8. Check all refrigerant system hoses, lines and the position of the newly installed filters to be sure they do not interfere with other engine compartment components. If necessary, use tie straps to
make adjustments.
9. Provide adequate airflow to the front of the vehicle (with a fan, if necessary). Select MAX A/C operation and set the blower motor speed to maximum. Start the engine and let it idle briefly.
Make sure the A/C system is operating correctly.
10. Gradually bring the engine up to 1,200 rpm by running it at lower rpms for short periods (first at 800 rpm, then at 1,000 rpm). Set the engine at 1,200 rpm and run it for one hour with the A/C
system operating.
11. Stop the engine.
12. Recover the refrigerant from the system. For additional information, refer to Air Conditioning (A/C) System Recovery, Evacuation and Charging in this section.
13. Remove the fittings, flexible hoses and pancake filter from between the and the condenser to evaporator tube.
14. Discard the pancake filter. It can be used one time only.
15. Reconnect the condenser to evaporator tube to the A/C condenser core.
16. Evacuate and charge the system. For additional information, refer to Air Conditioning (A/C) System Recovery, Evacuation and Charging in this section. Klj . 2 ba
22003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page 3125 of 4378

GENERAL PROCEDURES
Refrigerant Oil Adding
CAUTION: During normal A/C operation, oil is circulated through the system with the
refrigerant, and a small amount is retained in each component. If certain components of the
system are removed for new installation, some of the refrigerant oil will go with the component.
To maintain the original total oil charge, it is necessary to compensate for the oil lost by adding
oil to the system with the new part.
1. NOTE: Service A/C compressors are shipped without compressor oil.
Rotate the A/C compressor shaft six to eight revolutions while collecting oil in a clean measuring
device. zIf the amount of oil drained from the old A/C compressor is between 85- 142 ml (3-5
ounces), pour the same amount plus 30 ml (1 ounce) of clean PAG Refrigerant
Compressor Oil (R-134a Systems) F7AZ-19589- DA (Motorcraft YN-12-C) WSH M1C231-
B or equivalent into the new A/C compressor.
z If the amount of oil that was removed from the old A/C compressor is greater than 142 ml
(5 ounces), pour the same amount drained of clean PAG Refrigerant Compressor Oil (R-
134a Systems) or equivalent into the new A/C compressor.
z If the amount of oil that was removed from the old A/C compressor is less than 85 ml (3
ounces), pour 85 ml (3 ounces) of clean PAG Refrigerant Compressor Oil (R- 134a
Systems) or equivalent into the new A/C compressor.
2. For the suction accumulator/drier, drill one 13 mm (0.52 in) hole in the suction accumulator/drier cylinder and drain the oil into a calibrated container.
zAdd a quantity of new oil to match that drained from the old suction accumulator/drier
plus 60 ml (2 ounces) of clean PAG Refrigerant Compressor Oil (R- 134a Systems) or
equivalent.
3. For the A/C evaporator core, add 89 ml (3 ounces) of clean PAG Refrigerant Compressor Oil (R-134a Systems) or equivalent to the suction accumulator/drier inlet tube.
4. For the A/C condenser core, add 30 ml (1 ounce) of clean PAG Refrigerant Compressor Oil (R- 134a Systems) or equivalent to the A/C condenser core or the suction accumulator/drier inlet
tube.
5. Add 60 ml (2 ounces) of clean PAG Refrigerant Compressor Oil (R- 134a Systems) or equivalent
to the suction accumulator/drier inlet tube when carrying out each of the following repairs:
zinstallation of a new A/C evaporator core orifice
z installation of a new A/C compressor pressure relief valve (19D644)
z installation of a new refrigerant line
z repair of an O- ring seal leak
z repair of a charge port leak
6. Installation of new components that do not require discharge of refrigerant and resulting oil loss, such as the A/C cycling switch and the A/C pressure transducer, do not require additional oil.
SECTION 412-
00: Climate Control System - General Information 2003 Mustang Workshop Manual Klj . 1 ba
22003 Mustang Workshop Manual
18. 11. 2011file:///C:/Ford/2000 - 2004/tsocache/SHEF_2308/S3B~us~en~ ...

Page:   1-10 11-20 next >