gas type GEELY CK 2008 Workshop Manual

Page 18 of 392

11Component 2Figure 21Fan & Generator V-Belt
Vane-Type Pump V-Belt (V/ Power Steering)
V-Belt No.1Right Engine
Mounting InsulatorDoor AssemblySteering Column
AssemblyFront Shaft Hub Left NutLeft Front Speed Sensor Left Engine Mounting Bracket Steering Column Hole CoverHole Cover Steering Column Glove Compartment Front exhauxt pipe assembly
GasketGasket
One-off accessory

Page 24 of 392

17Section 3 Timing Belt ReplacementFigure 37Air Filter Assembly W/ HoseHigh Pressure CableVentilation PipeSeal
Cylinder Head
Right Engine Mounting
Fan & Generator V-Belt
V-Belt No.1Cylinder Head GasketGasket
Timing Chain Or Timing Belt Cover Assembly No. 2
Crankshaft Or Pulley
Cover Sub-Assembly
Crankshaft PulleyTiming Belt Guide
Timing Chain Timing Belt
Cover Sub-Assembly
Generator Assembly Timing Belt
Fan Pulley Vane-Type Pump V-Belt V/ Power Steering

Page 29 of 392

22Section 4 Camshaft ReplacementFigure 49Vane-Type Pump V-Belt
V/ Power Steering
Fan & Generator V-BeltHigh Pressure CableVentilation Pipe
V-Belt No.1
Cylinder Head
Cylinder
Head Gasket
Crankshaft Bearing Cap
Crankshaft Timing Belt WasherCrankshaft Counter GearWave GasketSnap RingCamshaftCamshaft No. 2Oil Seal
Camshaft Timing Pulley
Fan PulleyGenerator AssemblyCrankshaft Or Pulley
Cover Sub-AssemblyTiming Belt
Cover No. 2Air Filter Assembly W/ HoseRight Engine MountingSeal

Page 311 of 392

304Section 4 Service Caution & NoticeI. Service CautionRefrigerant Treatment
•During the treatment, the operator shall be careful not to inhale A/C refrigerant or lubricant vapor. Long-
term exposure to the A/C environment will cause the operator's eye, nose and throat liable to stimulation.
In addition, based on the consideration on the environment influence, when discharging the HFC-134a
from the A/C system, we suggest using the recyclable and rechargeable devices. If sudden system fault
occurs, it is recommended to place the device on a ventilated place before starting service.
•For HFC-134a service equipment, it is recommended not to perform the pressurization check or leakage
inspection. If these mixture combust, it may result in severe human injury or property loss.
•Please be noticed not to let the refrigerant leak near the spark or other hot objects. If the refrigerant gas
contacts the spark or similar heat source (e.g. cigarette or heater), it may generate poisonous gas. The
refrigerant is extremely liable to leakage during the transportation. In this case, please eliminate or remove
the heat source mentioned above and keep good ventilation.
•It is very dangerous to handle the liquid refrigerant. Only a drop of refrigerant can result in local frostbite
on skin if dropped on the skin of the operator. Therefore, it is specified that the operator shall always
wear glove and eye protection during the handling of the liquid refrigerant. If liquid refrigerant gets in
your eyes or on your skin, Wash the area with much cool water. Go immediately to hospital for professional
treatment.
Refrigerant Preservation
• Refrigerant preservation container is a high pressure resistant equipment. If it is put in hot treatment, the
explosion may arise, and the resulting metal fragments and the splashed liquid refrigerant will result in
severe human injury. It is recommended to preserve the refrigerant below 40°C.II. Service NoticeInsufficient Refrigerant Handling
•If the refrigerant is founded to be insufficient during the fault diagnosis, it is recommended not to add
refrigerant because of the following facts: the pressure readings indicated by different pressure gauge
are different, thus you will be unable to determine the exact amount of the refrigerant to be added, and
excessive or insufficient refrigerant may cause a series of chained negative effects such as damaged
refrigerant circulation parts or deteriorated refrigeration effect. Therefore, if the refrigerant is found to
be insufficient, it is recommended to drain the refrigerant from the refrigerant circulation pipeline and fill
specified amount of the refrigerant.
Compressor Oil Handling
•For this type of vehicle, it is recommended to use SW-100 type compressor oil. Use of PAG compressor
oil other than the SW-100 type may cause the A/C compressor to be damaged.
•During the operation, please be noticed not to splash the SW-100 type compressor oil onto the vehicle
surface. Therefore, if this happens, please wipe it off immediately, otherwise the compressor oil will
damage the paint on the vehicle surface.