ESP INFINITI FX35 2004 Service Manual

Page 2155 of 4449

EC-814
[VK45DE]
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
Revision: 2004 November 2004 FX35/FX45
DTC P0037, P0038, P0057, P0058 HO2S2 HEATERPFP:226A0
DescriptionABS00C0V
SYSTEM DESCRIPTION
The ECM performs ON/OFF control of the heated oxygen sensor 2 heater corresponding to the engine speed,
amount of intake air and engine coolant temperature.
OPERATION
CONSULT-II Reference Value in Data Monitor ModeABS00C0W
Specification data are reference values.
On Board Diagnosis LogicABS00C0X
Sensor Input signal to ECM ECM function Actuator
Camshaft position sensor (PHASE)
Crankshaft position sensor (POS)Engine speed
Heated oxygen sensor 2
heater controlHeated oxygen sensor 2 heater
Engine coolant temperature sensor Engine coolant temperature
Mass air flow sensor Amount of intake air
Engine speed rpm Heated oxygen sensor 2 heater
Above 3,600OFF
Below 3,600 rpm after the following conditions are met.
Engine: After warming up
Keeping the engine speed between 3,500 and 4,000 rpm for 1
minute and at idle for 1 minute under no loadON
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 HTR (B1)
HO2S2 HTR (B2)
Engine speed is below 3,600 rpm after the following conditions are met.
–Engine: After warming up
–Keeping the engine speed between 3,500 and 4,000 rpm for 1 minute and
at idle for 1 minute under no loadON
Engine speed: Above 3,600 rpm OFF
DTC No.Trouble diagnosis
nameDTC detecting condition Possible cause
P0037
0037
(Bank 1)Heated oxygen
sensor 2 heater
control circuit lowThe current amperage in the heated oxygen sen-
sor 2 heater circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM
through the heated oxygen sensor 2 heater.)
Harness or connectors
(The heated oxygen sensor 2 heater circuit is
open or shorted.)
Heater oxygen sensor 2 heater P0057
0057
(Bank 2)
P0038
0038
(Bank 1)Heated oxygen
sensor 2 heater
control circuit highThe current amperage in the heated oxygen sen-
sor 2 heater circuit is out of the normal range.
(An excessively high voltage signal is sent to
ECM through the heated oxygen sensor 2
heater.)
Harness or connectors
(The heated oxygen sensor 2 heater circuit is
shorted.)
Heater oxygen sensor 2 heater P0058
0058
(Bank 2)

Page 2164 of 4449

DTC P0101 MAF SENSOR
EC-823
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC Confirmation ProcedureABS00C16
Perform PROCEDURE FOR MALFUNCTION A first.
If the DTC cannot be confirmed, perform PROCEDURE FOR MALFUNCTION B.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
PROCEDURE FOR MALFUNCTION A
NOTE:
If engine will not start or stops soon, wait at least 10 seconds with engine stopped (Ignition switch ON) instead
of running engine at idle speed.
With CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and warm it up to normal operating temperature.
4. Run engine for at least 10 seconds at idle speed.
5. If DTC is detected, go to EC-826, "
Diagnostic Procedure" .
With GST
Follow the procedure “With CONSULT-II” above.
PROCEDURE FOR MALFUNCTION B
CAUTION:
Always drive vehicle at a safe speed.
With CONSULT-II
1. Turn ignition switch ON.
2. Start engine and warm it up to normal operating temperature.
If engine cannot be started, go to EC-826, "
Diagnostic Procedure" .
3. Select “DATA MONITOR” mode with CONSULT-II.
4. Check the voltage of “MAS A/F SE-B1” with “DATA MONITOR”.
5. Increases engine speed to about 4,000 rpm.
6. Monitor the linear voltage rise in response to engine speed
increases.
If NG, go to EC-826, "
Diagnostic Procedure" .
If OK, go to following step.
SEF174Y
SEF243Y

Page 2165 of 4449

EC-824
[VK45DE]
DTC P0101 MAF SENSOR
Revision: 2004 November 2004 FX35/FX45
7. Maintain the following conditions for at least 10 consecutive sec-
onds.
8. If DTC is detected, go to EC-826, "
Diagnostic Procedure" .
Overall Function CheckABS00C17
PROCEDURE FOR MALFUNCTION B
Use this procedure to check the overall function of the mass air flow sensor circuit. During this check, a DTC
might not be confirmed.
With GST
1. Start engine and warm it up to normal operating temperature.
2. Select MODE 1 with GST.
3. Check the mass air flow sensor signal with MODE 1.
4. Check for linear mass air flow sensor signal value rise in
response to increases to about 4,000 rpm in engine speed.
5. If NG, go to EC-826, "
Diagnostic Procedure" .
ENG SPEED More than 2,000 rpm
THRTL SEN 1 More than 3V
THRTL SEN 2 More than 3V
Selector lever Suitable position
Driving locationDriving vehicle uphill (Increased engine load) will help
maintain the driving conditions required for this test.
PBIB0199E
SEF534P

Page 2170 of 4449

DTC P0101 MAF SENSOR
EC-829
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Component InspectionABS00C1A
MASS AIR FLOW SENSOR
1. Reconnect all harness connectors disconnected.
2. Start engine and warm it up to normal operating temperature.
3. Check voltage between ECM terminal 51 (Mass air flow sensor
signal) and ground.
*: Check for linear voltage rise in response to engine being increased to about
4,000 rpm.
4. If the voltage is out of specification, proceed the following.
Turn ignition switch OFF.
Disconnect mass air flow sensor harness connector and reconnect it again.
Perform steps 2 and 3 again.
5. If NG, remove mass air flow sensor from air duct. Check hot film for damage or dust.
6. If NG, clean or replace mass air flow sensor.
Removal and InstallationABS00C1B
MASS AIR FLOW SENSOR
Refer to EM-172, "AIR CLEANER AND AIR DUCT" .
Condition Voltage V
Ignition switch ON (Engine stopped.) Approx. 1.0
Idle (Engine is warmed-up to normal
operating temperature.)1.2 - 1.8
2,500 rpm (Engine is warmed-up to
normal operating temperature.)1.7 - 2.4
Idle to about 4,000 rpm* 1.2 - 1.8 to Approx. 4.0
PBIB1106E

Page 2177 of 4449

EC-836
[VK45DE]
DTC P0102, P0103 MAF SENSOR
Revision: 2004 November 2004 FX35/FX45
Component InspectionABS00C1I
MASS AIR FLOW SENSOR
1. Reconnect all harness connectors disconnected.
2. Start engine and warm it up to normal operating temperature.
3. Check voltage between ECM terminal 51 (Mass air flow sensor
signal) and ground.
*: Check for linear voltage rise in response to engine being increased to about
4,000 rpm.
4. If the voltage is out of specification, proceed the following.
Turn ignition switch OFF.
Disconnect mass air flow sensor harness connector and reconnect it again.
Perform steps 2 and 3 again.
5. If NG, remove mass air flow sensor from air duct. Check hot film for damage or dust.
6. If NG, clean or replace mass air flow sensor.
Removal and InstallationABS00C1J
MASS AIR FLOW SENSOR
Refer to EM-172, "AIR CLEANER AND AIR DUCT" .
Condition Voltage V
Ignition switch ON (Engine stopped.) Approx. 1.0
Idle (Engine is warmed-up to normal
operating temperature.)1.2 - 1.8
2,500 rpm (Engine is warmed-up to
normal operating temperature.)1.7 - 2.4
Idle to about 4,000 rpm* 1.2 - 1.8 to Approx. 4.0
PBIB1106E

Page 2178 of 4449

DTC P0112, P0113 IAT SENSOR
EC-837
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0112, P0113 IAT SENSORPFP:22630
Component DescriptionABS00C1K
The intake air temperature sensor is built-into mass air flow sensor.
The sensor detects intake air temperature and transmits a signal to
the ECM.
The temperature sensing unit uses a thermistor which is sensitive to
the change in temperature. Electrical resistance of the thermistor
decreases in response to the temperature rise.
<Reference data>
*: These data are reference values and are measured between ECM terminal 34
(Intake air temperature sensor) and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output
voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM termi-
nals, such as the ground.
On Board Diagnosis LogicABS00C1L
DTC Confirmation ProcedureABS00C1M
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Wait at least 5 seconds.
4. If 1st trip DTC is detected, go to EC-840, "
Diagnostic Procedure"
.
SEC266C
Intake air temperature
°C (°F)Voltage* V Resistance kΩ
-10 (14) 4.43 7.9 - 9.3
25 (77) 3.32 1.9 - 2.1
80 (176) 1.23 0.31 - 0.37
SEF012P
DTC No.Trouble diagnosis
nameDTC detecting condition Possible cause
P0112
0112Intake air tempera-
ture sensor circuit
low inputAn excessively low voltage from the sensor is
sent to ECM.
Harness or connectors
(The sensor circuit is open or shorted.)
Intake air temperature sensor
P0113
0113Intake air tempera-
ture sensor circuit
high inputAn excessively high voltage from the sensor is
sent to ECM.
SEF058Y

Page 2189 of 4449

EC-848
[VK45DE]
DTC P0122, P0123 TP SENSOR
Revision: 2004 November 2004 FX35/FX45
DTC P0122, P0123 TP SENSORPFP:16119
Component DescriptionABS00C1Y
Electric throttle control actuator consists of throttle control motor,
throttle position sensor, etc. The throttle position sensor responds to
the throttle valve movement.
The throttle position sensor has the two sensors. These sensors are
a kind of potentiometers which transform the throttle valve position
into output voltage, and emit the voltage signal to the ECM. In addi-
tion, these sensors detect the opening and closing speed of the
throttle valve and feed the voltage signals to the ECM. The ECM
judges the current opening angle of the throttle valve from these sig-
nals and the ECM controls the throttle control motor to make the
throttle valve opening angle properly in response to driving condi-
tion.
CONSULT-II Reference Value in Data Monitor ModeABS00C1Z
Specification data are reference values.
*: Throttle position sensor 2 signal is converted by ECM internally. Thus, it differs from ECM terminal voltage signal.
On Board Diagnosis LogicABS00C20
These self-diagnoses have the one trip detection logic.
FAIL-SAFE MODE
When the malfunction is detected, ECM enters fail-safe mode and the MIL lights up.
PBIB0145E
MONITOR ITEM CONDITION SPECIFICATION
THRTL SEN1
THRTL SEN2*
Ignition switch: ON
(Engine stopped)
Shift lever: DAccelerator pedal: Fully released More than 0.36V
Accelerator pedal: Fully depressed Less than 4.75V
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0122
0122Throttle position sensor
2 circuit low inputAn excessively low voltage from the TP sensor
2 is sent to ECM.
Harness or connectors
(TP sensor 2 circuit is open or shorted.)
(APP sensor 2 circuit is shorted.)
Electric throttle control actuator
(TP sensor 2)
Accelerator pedal position sensor P0123
0123Throttle position sensor
2 circuit high inputAn excessively high voltage from the TP sen-
sor 2 is sent to ECM.
Engine operation condition in fail-safe mode
The ECM controls the electric throttle control actuator in regulating the throttle opening in order for the idle position to be within +10
degrees.
The ECM regulates the opening speed of the throttle valve to be slower than the normal condition.
So, the acceleration will be poor.

Page 2199 of 4449

EC-858
[VK45DE]
DTC P0127 IAT SENSOR
Revision: 2004 November 2004 FX35/FX45
DTC P0127 IAT SENSORPFP:22630
Component DescriptionABS00C2C
The intake air temperature sensor is built into mass air flow sensor.
The sensor detects intake air temperature and transmits a signal to
the ECM.
The temperature sensing unit uses a thermistor which is sensitive to
the change in temperature. Electrical resistance of the thermistor
decreases in response to the temperature rise.
<Reference data>
*: These data are reference values and are measured between ECM terminal 34
(Intake air temperature sensor) and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output
voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM termi-
nals, such as the ground.
On Board Diagnosis LogicABS00C2D
DTC Confirmation ProcedureABS00C2E
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
CAUTION:
Always drive vehicle at a safe speed.
TESTING CONDITION:
This test may be conducted with the drive wheels lifted in the shop or by driving the vehicle. If a road
test is expected to be easier, it is unnecessary to lift the vehicle.
WITH CONSULT-II
1. Wait until engine coolant temperature is less than 90°C (194°F)
a. Turn ignition switch ON.
SEC266C
Intake air temperature
°C (°F)Voltage* V Resistance kΩ
–10 (14) 4.43 7.9 - 9.3
25 (77) 3.32 1.9 - 2.1
80 (176) 1.23 0.31 - 0.37
SEF012P
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0127
0127Intake air temperature
too highRationally incorrect voltage from the sensor is
sent to ECM, compared with the voltage signal
from engine coolant temperature sensor.
Harness or connectors
(The sensor circuit is open or shorted)
Intake air temperature sensor

Page 2209 of 4449

EC-868
[VK45DE]
DTC P0132, P0152 HO2S1
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS00C2S
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
Refer to EC-791, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
2. RETIGHTEN HEATED OXYGEN SENSOR 1
1. Loosen and retighten corresponding heated oxygen sensor 1.
>> GO TO 3.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
35 BRHeated oxygen sensor 1
(bank 2)[Engine is running]
Warm-up condition
Engine speed is 2,000 rpm0 - Approximately 1.0V
(Periodically change)
78 B/RSensor ground
(Heated oxygen sensor)[Engine is running]
Warm-up condition
Idle speedApproximately 0V
PBIB2195E
Tightening torque: 50 N·m (5.1 kg-m, 37 ft-lb)
PBIB1520E

Page 2213 of 4449

EC-872
[VK45DE]
DTC P0133, P0153 HO2S1
Revision: 2004 November 2004 FX35/FX45
DTC P0133, P0153 HO2S1PFP:22690
Component DescriptionABS00C2V
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1 to 0V.
CONSULT-II Reference Value in Data Monitor ModeABS00C2W
Specification data are reference values.
On Board Diagnosis LogicABS00C2X
To judge the malfunction of heated oxygen sensor 1, this diagnosis
measures response time of heated oxygen sensor 1 signal. The time
is compensated by engine operating (speed and load), fuel feedback
control constant, and heated oxygen sensor 1 temperature index.
Judgment is based on whether the compensated time (heated oxy-
gen sensor 1 cycling time index) is inordinately long or not.
SEF463R
SEF288D
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
Engine: After warming upMaintaining engine speed at 2,000
rpm0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S1 MNTR (B1)
HO2S1 MNTR (B2)LEAN ←→ RICH
Changes more than 5 times
during 10 seconds.
SEF010V