BL-38
POWER DOOR LOCK SYSTEM
Revision: 2004 November 2004 FX35/FX45
Preliminary CheckAIS004LY
FUSE AND FUSIBLE LINK CHECK
1. FUSE INSPECTION
Check the following fuse and fusible link.
NOTE:
Refer to BL-22, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse, refer to PG-
3, "POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connectors.
3. Check voltage between BCM connectors M4 terminals 42, 55
and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace BCM power supply circuit.
3. CHECK GROUND CIRCUIT
Check continuity between BCM connectors M4 terminals 49, 52 and
ground.
OK or NG
OK >> Power supply and ground circuit are OK.
NG >> Repair or replace BCM ground circuit.
Unit Signal name No, Location
BCMBattery power supply 22 (15A) Fuse block (J/B)
Battery power supply M (50A) Fuse and fusible link box
BCM – Ground
42 (L/R) – Ground : Battery voltage
55 (G) – Ground : Battery voltage
PIIA6374E
BCM – Ground
49 (B) – Ground : Continuity should exist.
52 (B) – Ground : Continuity should exist.
ConnectorTerminals
(Wire color)
Continuity
(+) (–)
M449 (B)
Ground Yes
52 (B)
PIIA6375E

Page 849 of 4449

BL-42
POWER DOOR LOCK SYSTEM
Revision: 2004 November 2004 FX35/FX45
Check Door SwitchAIS004M1
CHECK DOOR SWITCH (EXCEPT BACK DOOR SWITCH)
1. CHECK DOOR SWITCH INPUT SIGNAL
With CONSULT-II
Check door switches (“DOOR SW-DR”, “DOOR SW-AS”, “DOOR
SW-RL” and “DOOR SW-RR”) in “DATA MONITOR” mode with
CONSULT-II.
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK >> Door switch circuit is OK.
NG >> GO TO 2.
Monitor item Condition
DOOR SW-DR
CLOSE → OPEN: OFF → ON DOOR SW-AS
DOOR SW-RL
DOOR SW-RR
Item ConnectorTerminals
(Wire color)Door
conditionVoltage (V)
(Approx.)
(+) (-)
Driver side
B1462 (W)
GroundCLOSE

OPENBattery voltage

0 Rear LH 63 (P)
Passenger side
M312 (P/B)
Rear RH 13 (P/L)
PIIA6469E
PIIA7003E

Page 853 of 4449

BL-46
POWER DOOR LOCK SYSTEM
Revision: 2004 November 2004 FX35/FX45
4. CHECK BACK DOOR SWITCH GROUND HARNESS
Check continuity between back door switch connector D109 terminal
8 and ground.
OK or NG
OK >> Check harness connection.
NG >> Repair or replace harness.
Check Key SwitchAIS004M2
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check ignition key switch “KEY ON SW” in “DATA MONITOR” mode
with CONSULT-II.
When key is inserted in ignition key cylinder
When key is removed from ignition key cylinder
Without CONSULT-II
Check voltage between BCM connector M3 terminal 37 (B/W) and ground.
OK or NG
OK >> Key switch circuit is OK.
NG >> GO TO 2. (with intelligent key)
NG >> GO TO 3. (without intelligent key)8 (B) – Ground : Continuity should exist.
PIIA6477E
KEY ON SW : ON
KEY ON SW : OFF
PIIA6470E
Condition of key switchVoltage (V)
Approx.
Key switch is “ON”. (Key is inserted in IGN key cylinder.) Battery voltage
Key switch is “OFF”. (Key is removed from IGN key cylinder.) 0
PIIA6378E

Page 858 of 4449

POWER DOOR LOCK SYSTEM
BL-51
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2004 November 2004 FX35/FX45
2. CHECK OUTPUT SIGNAL
1. Connect BCM and door lock actuator (driver side) connector.
2. Check voltage between BCM connector M4 terminals 44, 50 and
ground.
OK or NG
OK >> Check harness connection.
NG >> Replace BCM.
Check Door Lock Actuator (Passenger Side and Rear LH/RH)AIS004M5
1. CHECK DOOR LOCK ACTUATOR HARNESS
1. Disconnect BCM and each door lock actuator connectors.
2. Check continuity between BCM connector M4 terminals 50, 51
and front door lock actuator passenger side, rear door lock actu-
ator LH/RH connectors D40, D52, D72 terminals 2, 3.
3. Check continuity between BCM connector M4 terminals 50, 51
and ground.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace harness.
Con-
nectorTerminal
(Wire color)
ConditionVoltage (V)
(Approx.)
(+) (–)
M444 (Y)
GroundDriver door lock/unlock
switch is turned to UNLOCK.0 → Battery voltage
50 (PU)Driver door lock/unlock
switch is turned to LOCK.0 → Battery voltage
PIIA6383E
50 (PU) – 3 (PU) : Continuity should exist.
51 (W/B) – 2 (L or Y) : Continuity should exist.
50 (PU) – Ground : Continuity should not exist.
51 (W/B) – Ground : Continuity should not exist.
PIIA6540E

Page 859 of 4449

BL-52
POWER DOOR LOCK SYSTEM
Revision: 2004 November 2004 FX35/FX45
2. CHECK DOOR LOCK ACTUATOR SIGNAL
Check voltage between BCM connector M4 terminals 50, 51 and
ground.
OK or NG
OK >> Replace front door lock assembly (passenger side) or rear door lock actuator LH/RH.
NG >> Replace BCM.
Check Fuel Lid Opener Actuator AIS004M6
1. CHECK FUEL LID OPENER ACTUATOR HARNESS
1. Turn ignition switch OFF.
2. Disconnect BCM and fuel lid lock actuator connector.
3. Check continuity between BCM connector M4 terminals 44, 50
and fuel lid lock actuator connector B70 terminals 1, 2.
4. Check continuity between BCM connector M4 terminals 44, 50
and ground.
OK or NG
OK >> Replace fuel lid actuator.
NG >> Repair or replace harness.
Con-
nectorTerminal
(Wire color)
ConditionVoltage (V)
(Approx.)
(+) (–)
M450 (PU)
GroundDoor lock/unlock switch
is turned to LOCK.0 → Battery voltage
51 (W/B)Door lock/unlock switch
is turned to UNLOCK.0 → Battery voltage
PIIA6385E
44 (Y) – 2 (L) : Continuity should exist.
50 (PU) – 1 (PU) : Continuity should exist.
44 (Y) – Ground : Continuity should not exist.
50 (PU) – Ground : Continuity should not exist.
PIIA6386E

Page 871 of 4449

BL-64
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2004 November 2004 FX35/FX45
Terminals and Reference Value for BCMAIS004MF
*1 : In the state that hazard reminder operates.
*2 : In the state that room lamp switch is in “DOOR” position.TERMI-
NALWIRE
COLORITEM CONDITIONVOLTAGE (V)
Approx.
1PUKey ring illumination output sig-
nal Key ring illumination is lighting. Battery voltage
Key ring illumination is being turned off. 0
11 LG/R Ignition switch Ignition switch is in ACC or ON position Battery voltage
12 P/BFront door switch (Passenger
side)ON (door open) → OFF (door closed) 0 → Battery voltage
13 P/L Rear door switch RH ON (door open) → OFF (door closed) 0 → Battery voltage
37 B/W Key switchON (Key is inserted in IGN key cylinder)
→ OFF (Key is removed from IGN key
cylinder)Battery voltage → 0
38 W/L Ignition switchIgnition switch is in ON or START posi-
tionBattery voltage
39 L CAN H — —
40 R CAN L — —
41 R/B Battery saver output signal30 minutes after ignition switch is turned
to OFF0
Ignition switch is in ON position Battery voltage
42 L/R Battery power supply (fuse) — Battery voltage
44 YDriver door lock actuator
(Unlock)Door lock / unlock switch
(Free → Unlock)0 → Battery voltage
45 G/W Left turn signal lampWhen door lock or unlock is operated
using key fob.*
1
(ON → OFF)Battery voltage → 0
46 BR/W Right turn signal lampWhen door lock or unlock is operated
using key fob.*
1
(ON → OFF)Battery voltage → 0
47 Y/R Step lamp output signalStep lamp is lighting. 0
Step lamp is being turned off. Battery voltage
48 PU/W Room lamp output signalRoom lamp is lighting.*
20
Room lamp is being turned off.*
2Battery voltage
49, 52 B Ground — 0
50 PU Door lock actuator (Lock)Door lock / unlock switch
(Free → Lock)0 → Battery voltage
51 W/BPassenger and rear doors lock
actuator (Unlock)Door lock / unlock switch
(Free → Unlock)0 → Battery voltage
54 WBattery power supply
(power window)—Battery voltage
55 GBattery power supply (Fusible
link)—Battery voltage
58 L Back door switch OFF (Door close) → ON (Door open) 9 → 0
62 W Front door switch (Driver side) OFF (Door close) → ON (Door open) Battery voltage → 0
63 P Rear door switch LH OFF (Door close) → ON (Door open) Battery voltage → 0

Page 872 of 4449

REMOTE KEYLESS ENTRY SYSTEM
BL-65
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2004 November 2004 FX35/FX45
Terminals and Reference Value for IPDM E/RAIS004MG
* : In the state that horn reminder operates.
CONSULT-II FunctionAIS004MH
The following functions are performed by combining data received and command transmitted via the commu-
nication line from the BCM.
*:Refer to BCS-14, "CAN Communication Inspection Using CONSULT-II (Self-Diagnosis)" .
CONSULT-II INSPECTION PROCEDURE
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carry out CAN communication.
1. Turn ignition switch “OFF”.
2. Connect “CONSULT-II” and “CONSULT-II CONVERTER” to the
data link connector.
3. Turn ignition switch “ON”.
4. Touch “START (NISSAN BASED VHCL)”.
TERMINAL WIRE
COLORITEM CONDITIONVOLTAGE (V)
Approx.
38 B Ground — 0
48 L CAN H — —
49 R CAN L — —
51 SB Horn relayWhen door lock is operated using key
fob* (OFF → ON)Battery voltage → 0
60 B Ground — 0
BCM diagnosis
positionInspection items and diagnosis mode Description
BCM C/U*Self-diagnosis results Carries out the self-diagnosis.
DATA MONI-
TORCAN diagnosis support
monitorDisplays CAN communication system diagnosis, disabled
transmission status, and communication status of each unit
communicated with BCM.
Selection from menu Displays the input data to BCM on real-time basis.
MULTI REMOTE
ENTDATA MONITORDisplays the input remote keyless entry system data to BCM
on real–time basis.
ACTIVE TEST Gives a drive to a load to check the operation.
WORK SUPPORT Changes the setting for each function.
PBIB1503E
MBIB0233E

Page 876 of 4449

REMOTE KEYLESS ENTRY SYSTEM
BL-69
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2004 November 2004 FX35/FX45
Trouble Diagnosis Chart by SymptomAIS004MJ
NOTE:
Always check the “Work Flow” before troubleshooting. Refer to BL-68, "Work Flow" .
Always check key fob battery before replacing key fob.
Symptom Diagnoses/service procedureReference
page
All function of remote keyless entry system do not
operate.1. Check key fob battery and function.BL-71
2. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning.BL-80
3. Replace BCM.BCS-15
The new ID of key fob cannot be entered.1. Check key fob battery and function.BL-71
2. Check key switch.BL-77
3. Check door switch.BL-73
4. Check ACC switch.BL-72
5. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning.BL-80
6. Replace BCM.BCS-15
Door lock or unlock does not function with key fob.
(Power door lock system is “OK”.)1. Check key fob battery and function.BL-71
2. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning.BL-80
3. Replace BCM.BCS-15
Hazard and horn reminder does not activate prop-
erly when pressing lock or unlock button of key fob.1. Check hazard and horn reminder mode.*
*: Hazard and horn reminder mode can be changed.
First check the hazard and horn reminder setting.BL-67
2. Check door switch.BL-73
3. Replace BCM.BCS-15
Hazard reminder does not activate properly when
pressing lock or unlock button of key fob.
(Horn reminder is “OK”.)1. Check hazard reminder mode.*
*: Hazard reminder mode can be changed.
First check the hazard reminder setting.BL-67
2. Check hazard function with hazard switch.BL-79
3. Replace BCM.BCS-15
Horn reminder does not activate properly when
pressing lock button of key fob.
(Hazard reminder is “OK”.)1. Check horn reminder mode.*
*: Horn reminder can be changed.
First check the horn chirp setting.BL-67
2. Check horn function.BL-79
3. Check IPDM E/R operation.BL-78
4. Replace BCM.BCS-15

Page 877 of 4449

BL-70
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2004 November 2004 FX35/FX45
Panic alarm (horn and headlamp) does not activate
when panic alarm button is continuously pressed.1. Check panic alarm mode.*
*: Panic alarm mode can be changed.
First check the panic alarm setting.BL-67
2. Check key fob battery and function.BL-71
3. Check headlamp function.BL-79
4. Check horn function.BL-79
5. Check IPDM E/R operation.BL-78
6. Check key switch.BL-77
7. Replace key fob. Refer to ID Code Entry Procedure.
NOTE:
If the result of key fob function check with CONSULT-II is OK, key
fob is not malfunctioning.BL-80
8. Replace BCM.BCS-15
Auto door lock operation does not activate properly.
(All other remote keyless entry system function is
OK.)1. Check auto door lock operation mode.*
*: Auto door lock operation mode can be changed.
First check the auto door lock operation setting.BL-67
2. Replace BCM.BCS-15
Keyless power window down (open) operation does
not activate properly.
(All other remote keyless entry system function is
OK.)1. Check power window down operation mode.*
*: Power window down operation mode can be changed.
First check the power window down setting.BL-67
2. Check power window function.GW-15
3. Replace BCM.BCS-15
Map lamp and ignition keyhole illumination opera-
tion does not activate properly.1. Check map lamp and ignition keyhole illumination operation.BL-792. Check door switch.BL-73
3. Replace BCM.BCS-15
Symptom Diagnoses/service procedureReference
page

Page 878 of 4449

REMOTE KEYLESS ENTRY SYSTEM
BL-71
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2004 November 2004 FX35/FX45
Check Key Fob Battery and FunctionAIS004MK
1. CHECK KEY FOB BATTERY
1. Remove key fob battery. Refer to BL-83, "
Key Fob Battery Replacement" .
2. Measure voltage between battery positive and negative termi-
nals, (+) and (−).
NOTE:
Key fob does not function if battery is not set correctly.
OK or NG
OK >> GO TO 2.
NG >> Replace battery.
2. CHECK KEY FOB FUNCTION
With CONSULT-II
Check key fob function in “DATA MONITOR” mode with CONSULT-
II. When pushing each button of key fob, the corresponding monitor
item should be turned as follows.
OK or NG
OK >> Key fob is OK.
NG >> Replace key fob.Voltage : 2.5 – 3.0V
SEL237W
Condition Monitor item
Pushing LOCK KEYLESS LOCK : ON
Pushing UNLOCK KEYLESS UNLOCK : ON
Keep pushing UNLOCKRKE KEEP UNLK : ON
*: UN BUTTON ON turns to ON three sec-
onds after UNLOCK button keeps pushing.
Pushing PANIC KEYLESS PANIC : ON
Pushing LOCK and UNLOCK at the
same timeRKE LCK-UNLOCK : ON
PIIA6468E

Page:   < prev 1-10 ... 41-50 51-60 61-70 71-80 81-90 91-100 101-110 111-120 121-130 ... 740 next >