ignition INFINITI FX35 2004 Service Manual
Page 2332 of 4449
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-991
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
On Board Diagnosis LogicABS00C5R
DTC Confirmation ProcedureABS00C5S
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and let it idle for at least 13 seconds.
4. If 1st trip DTC is detected, go to EC-994, "
Diagnostic Procedure"
.
WITH GST
Follow the procedure “WITH CONSULT-II” above.
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0444
0444EVAP canister purge volume
control solenoid valve circuit
openAn excessively low voltage signal is sent
to ECM through the valve
Harness or connectors
(The solenoid valve circuit is open or
shorted.)
EVAP canister purge volume control
solenoid valve
P0445
0445EVAP canister purge volume
control solenoid valve circuit
shortedAn excessively high voltage signal is sent
to ECM through the valve
Harness or connectors
(The solenoid valve circuit is shorted.)
EVAP canister purge volume control
solenoid valve
SEF058Y
Page 2334 of 4449
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-993
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
45 WEVAP canister purge vol-
ume control solenoid valve[Engine is running]
Idle speedBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Engine speed is about 2,000 rpm (More
than 100 seconds after starting engine)11 - 1 4 V
111 W / BECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFFBATTERY VOLTAGE
(11 - 14V)
11 9
120R
RPower supply for ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
PBIB0050E
PBIB0051E
Page 2335 of 4449
EC-994
[VK45DE]
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
Revision: 2004 November 2004 FX35/FX45
Diagnostic ProcedureABS00C5U
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIR-
CUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve
harness connector.
3. Turn ignition switch ON.
4. Check voltage between EVAP canister purge volume control
solenoid valve terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors M82, F102
Joint connector-3
Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 45 and EVAP canister purge volume control solenoid
valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK (With CONSULT-II)>>GO TO 4.
OK (Without CONSULT-II)>>GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB1478E
Voltage: Battery voltage
PBIB0148E
Continuity should exist.
Page 2338 of 4449
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-997
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P0447 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component DescriptionABS00C5X
The EVAP canister vent control valve is located on the EVAP canis-
ter and is used to seal the canister vent.
This solenoid valve responds to signals from the ECM. When the
ECM sends an ON signal, the coil in the solenoid valve is energized.
A plunger will then move to seal the canister vent. The ability to seal
the vent is necessary for the on board diagnosis of other evaporative
emission control system components.
This solenoid valve is used only for diagnosis, and usually remains
opened.
When the vent is closed, under normal purge conditions, the evapo-
rative emission control system is depressurized and allows “EVAP
Control System” diagnosis.
CONSULT-II Reference Value in Data Monitor ModeABS00C5Y
Specification data are reference values.
On Board Diagnosis LogicABS00C5Z
PBIB1263E
PBIB1522E
MONITOR ITEM CONDITION SPECIFICATION
VENT CONT/V
Ignition switch: ON OFF
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0447
0447EVAP canister vent con-
trol valve circuit openAn improper voltage signal is sent to ECM
through EVAP canister vent control valve.
Harness or connectors
(The valve circuit is open or shorted.)
EVAP canister vent control valve
Page 2339 of 4449
EC-998
[VK45DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2004 November 2004 FX35/FX45
DTC Confirmation ProcedureABS00C60
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and wait at least 8 seconds.
4. If 1st trip DTC is detected, go to EC-1000, "
Diagnostic Proce-
dure" .
WITH GST
Follow the procedure “WITH CONSULT-II” above.
SEF058Y
Page 2341 of 4449
EC-1000
[VK45DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS00C62
1. INSPECTION START
Do you have CONSULT-II?
Ye s o r N o
Yes >> GO TO 2.
No >> GO TO 3.
2. CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT
With CONSULT-II
1. Turn ignition switch OFF and then turn ON.
2. Select “VENT CONTROL/V” in “ACTIVE TEST” mode with CONSULT-II.
3. Touch “ON/OFF” on CONSULT-II screen.
4. Check for operating sound of the valve.
Clicking noise should be heard.
OK or NG
OK >> GO TO 7.
NG >> GO TO 3.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
11 7 R / YEVAP canister vent control
valve[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
PBIB0151E
Page 2342 of 4449
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
EC-1001
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister vent control valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between EVAP canister vent control valve termi-
nal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors M11, B1
Harness connectors B84, B216
IPDM E/R harness connector E7
10A fuse
Harness for open or short between EVAP canister vent control valve and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 117 and EVAP canister vent control valve terminal 2.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.Voltage: Battery voltage
PBIB1522E
PBIB0152E
Continuity should exist.
Page 2343 of 4449
EC-1002
[VK45DE]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
Revision: 2004 November 2004 FX35/FX45
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors B216, B84
Harness connectors M11, B1
Harness for open or short between EVAP canister vent control valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
7. CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EVAP canister vent control valve.
2. Check the rubber tube for clogging.
OK or NG
OK >> GO TO 8.
NG >> Clean the rubber tube using an air blower.
8. CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to EC-1002, "
Component Inspection" .
OK or NG
OK >> GO TO 9.
NG >> Replace EVAP canister vent control valve.
9. CHECK INTERMITTENT INCIDENT
Refer to EC-784, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionABS00C63
EVAP CANISTER VENT CONTROL VALVE
With CONSULT-II
1. Remove EVAP canister vent control valve from EVAP canister.
2. Check portion B of EVAP canister vent control valve for being
rusted.
If NG, replace EVAP canister vent control valve.
If OK, go to next step.
3. Reconnect harness connectors disconnected.
4. Turn ignition switch ON.
PBIB1033E
Page 2345 of 4449
EC-1004
[VK45DE]
DTC P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR
Revision: 2004 November 2004 FX35/FX45
DTC P0451 EVAP CONTROL SYSTEM PRESSURE SENSORPFP:22365
Component DescriptionABS00C64
The EVAP control system pressure sensor detects pressure in the purge line. The sensor output voltage to the
ECM increases as pressure increases.
CONSULT-II Reference Value in Data Monitor ModeABS00C65
Specification data are reference values.
On Board Diagnosis LogicABS00C66
NOTE:
If DTC P0451 is displayed with DTC P1229, first perform the trouble diagnosis for DTC P1229. Refer to
EC-1156
.
PBIB1522E
PBIB1207E
MONITOR ITEM CONDITION SPECIFICATION
EVAP SYS PRES
Ignition switch: ON Approx. 1.8 - 4.8V
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0451
0451EVAP control system
pressure sensor perfor-
manceECM detects a sloshing signal from the EVAP
control system pressure sensor
Harness or connectors
EVAP control system pressure sensor
Page 2346 of 4449
DTC P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-1005
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC Confirmation ProcedureABS00C67
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
3. Start engine and wait at least 40 seconds.
NOTE:
Do not depress accelerator pedal even slightly.
If 1st trip DTC is detected, go to EC-1005, "
Diagnostic Proce-
dure" .
WITH GST
Follow the procedure “WITH CONSULT-II” above.
Diagnostic ProcedureABS00C68
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
Refer to EC-791, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
SEF194Y