Ignition switch INFINITI FX35 2005 Service Manual

Page 2051 of 4731

EC-658
[VQ35DE]
IGNITION SIGNAL
Revision: 2005 July 2005 FX
12. CHECK IGNITION COIL GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Check harness continuity between ignition coil terminal 2 and ground. Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 14.
NG >> GO TO 13.
13. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F211, F10
Harness for open or short between ignition coil and ground
>> Repair open circuit or short to power in harness or connectors.
14. CHECK IGNITION COIL OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminals 60, 61, 62, 79, 80, 81 and ignition coil terminal 1. Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 16.
NG >> GO TO 15.
15. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F10, F211
Harness for open or short between ignition coil and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
16. CHECK IGNITION COIL WITH POWER TRANSISTOR
Refer to EC-659, "
Component Inspection" .
OK or NG
OK >> GO TO 17.
NG >> Replace ignition coil with power transistor.
17. CHECK INTERMITTENT INCIDENT
Refer to EC-163, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or Ng
OK >> Replace IPDM E/R.
NG >> Repair open circuit or short to ground a short to power in harness connectors. Continuity should exist.
Continuity should exist.

Page 2052 of 4731

IGNITION SIGNAL EC-659
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Component InspectionABS006Y7
IGNITION COIL WITH POWER TRANSISTOR
CAUTION:
Do the following procedure in the place where ventilation is good without the combustible.
1. Turn ignition switch OFF.
2. Disconnect ignition coil harness connector.
3. Check resistance between ignition coil terminals as follows.
4. If NG, Replace ignition coil with power transistor. If OK, go to next step.
5. Turn ignition switch OFF.
6. Reconnect all harness connectors disconnected.
7. Remove fuel pump fuse in IPDM E/R to release fuel pressure.
NOTE:
Do not use CONSULT-II to release fuel pressure, or fuel pres-
sure applies again during the following procedure.
8. Start engine.
9. After engine stalls, crank it 2 or 3 times to release all fuel pres- sure.
10. Turn ignition switch OFF.
11. Remove ignition coil harness connectors to avoid the electrical discharge from the ignition coils.
12. Remove ignition coil and spark plug of the cylinder to be checked.
13. Crank engine for 5 seconds or more to remove combustion gas in the cylinder.
14. Connect spark plug and harness connector to ignition coil.
15. Fix ignition coil using a rope etc. with gap of 13 - 17 mm between the edge of the spark plug and grounded metal portion
as shown in the figure.
16. Crank engine for about three seconds, and check whether spark is generated between the spark plug and the grounded part.
CAUTION:
Do not approach to the spark plug and the ignition coil
within 50cm. Be careful not to get an electrical shock
while checking, because the electrical discharge voltage
becomes 20kV or more.
It might cause to damage the ignition coil if the gap of 17 mm or more is taken.
NOTE:
When the gap is 13 mm or less, the spark might be generated even if the coil is malfunctioning.
17. If NG, Replace ignition coil with power transistor.
Terminal No. (Polarity) Resistance Ω [at 25 °C (77 °F)]
1 and 2 Except 0 or ∞
1 and 3 Except 0
2 and 3
Spark should be generated.
PBIB0847E
PBIB1603E
PBIB2325E

Page 2053 of 4731

EC-660
[VQ35DE]
IGNITION SIGNAL
Revision: 2005 July 2005 FX
CONDENSER
1. Turn ignition switch OFF.
2. Disconnect condenser harness connector.
3. Check resistance between condenser terminals 1 and 2.
Removal and InstallationABS006Y8
IGNITION COIL WITH POWER TRANSISTOR
Refer to EM-42, "IGNITION COIL" .
Resistance: Above 1 M
Ω at 25 °C (77 °F)
PBIB0794E

Page 2056 of 4731

INJECTOR CIRCUIT EC-663
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureABS006YC
1. INSPECTION START
Turn ignition switch to START.
Is any cylinder ignited?
Ye s o r N o
Yes (With CONSULT-II)>>GO TO 2.
Yes (without CONSULT-II)>>GO TO 3.
No >> GO TO 6.
2. CHECK OVERALL FUNCTION
With CONSULT-II
1. Start engine.
2. Perform “POWER BALANCE” in “ACTIVE TEST” mode with CONSULT-II.
3. Make sure that each circuit produces a momentary engine speed drop.
OK or NG
OK >> INSPECTION END
NG >> GO TO 6.
TER-
MINAL
NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
21
22
23
40
41
42 W
G
R
LG
B
P Injector No. 5
Injector No. 3
Injector No. 1
Injector No. 6
Injector No. 4
Injector No. 2 [Engine is running]
Warm-up condition
Idle speed
NOTE:
The pulse cycle changes depending on rpm
at idle BATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Warm-up condition
Engine speed is 2,000 rpm BATTERY VOLTAGE
(11 - 14V)
SEC984C
SEC985C
PBIB0133E

Page 2057 of 4731

EC-664
[VQ35DE]
INJECTOR CIRCUIT
Revision: 2005 July 2005 FX
3. CHECK FUNCTION OF INJECTOR-I
With out CONSULT-II
1. Turn ignition switch OFF.
2. Disconnect harness connector F50, F251
3. Turn ignition switch ON.
4. Check voltage between harness connector F50 terminal 5 and ground with CONSULT-II or tester.
5. Turn ignition switch OFF.
6. Disconnect ECM harness connector.
7. Check harness continuity between harness connector F50 and ECM as follows.
Refer to Wiring Diagram.
8. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M82, F102
Harness connectors F50, F251
Fuse block (J/B) connector M4
15A fuse
Harness for open or short between harness connector F50 and fuse
Harness for open or short between harness connector F50 and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB2624E
Voltage: Battery voltage
Cylinder Harness connector F50
terminal ECM terminal
1623
2442
3222
4341
5121
6740
Continuity should exist.
PBIB2323E

Page 2058 of 4731

INJECTOR CIRCUIT EC-665
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
5. CHECK FUNCTION OF INJECTOR-II
Provide battery voltage between harness connector F251 as follows
and then interrupt it. Listen to each injector operating sound.
OK or NG
OK >> INSPECTION END
NG >> GO TO 6.
6. CHECK INJECTOR POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect injector harness connector.
3. Turn ignition switch ON.
4. Check voltage between injector terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
Cylinder Harness connector F251 terminal
(+) (–)
156
254
352
453
551
657
Operating sound should exist.
PBIB2497E
PBIB1561E
Voltage: Battery voltage
PBIB0582E

Page 2059 of 4731

EC-666
[VQ35DE]
INJECTOR CIRCUIT
Revision: 2005 July 2005 FX
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M82, F102
Harness connectors F50, F251
Fuse block (J/B) connector M4
10A fuse
Harness for open or short between injector and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
8. CHECK INJECTOR OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between injector terminal 2 and ECM terminals 21, 22, 23, 40, 41, 42. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 10.
NG >> GO TO 9.
9. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F251, F50
Harness for open or short between injector and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
10. CHECK INJECTOR
Refer to EC-667, "
Component Inspection" .
OK or NG
OK >> GO TO 11.
NG >> Replace injector.
11 . CHECK INTERMITTENT INCIDENT
Refer to EC-163, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>> INSPECTION END
Continuity should exist.

Page 2061 of 4731

EC-668
[VQ35DE]
FUEL PUMP CIRCUIT
Revision: 2005 July 2005 FX
FUEL PUMP CIRCUITPFP:17042
DescriptionABS006YF
SYSTEM DESCRIPTION
*: ECM determines the start signal status by the signals of engine speed and battery voltage.
The ECM activates the fuel pump for several seconds after the ignition switch is turned ON to improve engine
start ability. If the ECM receives a engine speed signal from the camshaft position sensor (PHASE), it knows
that the engine is rotating, and causes the pump to operate. If the engine speed signal is not received when
the ignition switch is ON, the engine stalls. The ECM stops pump operation and prevents battery discharging,
thereby improving safety. The ECM does not directly drive the fuel pump. It controls the ON/OFF fuel pump
relay, which in turn controls the fuel pump.
COMPONENT DESCRIPTION
A turbine type design fuel pump is used in the furl tank.
CONSULT-II Reference Value in Data Monitor ModeABS006YG
Specification data are reference values.
Sensor Input Signal to ECM ECM Function Actuator
Crankshaft position sensor (POS)
Camshaft position sensor (PHASE) Engine speed*
Fuel pump control Fuel pump relay
Battery Battery voltage*
Condition Fuel pump operation
Ignition switch is turned to ON. Operates for 1 second.
Engine running and cranking Operates.
When engine is stopped Stops in 1.5 seconds.
Except as shown above Sto ps.
PBIB1569E
MONITOR ITEM CONDITION SPECIFICATION
FUEL PUMP RLY
For 1 second after turning ignition switch ON
Engine running or cranking ON
Except above conditions OFF

Page 2063 of 4731

EC-670
[VQ35DE]
FUEL PUMP CIRCUIT
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS006YI
1. CHECK OVERALL FUNCTION
1. Turn ignition switch ON.
2. Pinch fuel feed hose with two fingers. Fuel pressure pulsation should be felt on the fuel feed hose
for 1 second after ignition switch is turned ON.
OK or NG
OK >> INSPECTION END
NG >> GO TO 2.
2. CHECK FUEL PUMP POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Turn ignition switch ON.
4. Check voltage between ECM terminal 113 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 3.
3. CHECK FUEL PUMP POWER SUPPLY CIRCUIT-II
Check voltage between IPDM E/R terminal 40 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 11.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
11 3 G Y / R F u e l p u m p r e l a y [Ignition switch: ON]
For 1 second after turning ignition switch ON
[Engine is running] 0 - 1.5V
[Ignition switch: ON]
More than 1 second after turning ignition
switch ON BATTERY VOLTAGE
(11 - 14V)
PBIB1612E
Voltage: Battery voltage
PBIB1187E
Voltage: Battery voltage

Page 2064 of 4731

FUEL PUMP CIRCUIT EC-671
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness for open or short between IPDM E/R and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK FUEL PUMP POWER SUPPLY CIRCUIT-III
1. Turn ignition switch OFF.
2. Reconnect all harness connectors disconnected.
3. Disconnect “fuel level sensor unit and fuel pump” harness con- nector.
4. Turn ignition switch ON.
5. Check voltage between “fuel level sensor unit and fuel pump” terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 9.
NG >> GO TO 6.
6. CHECK 15A FUSE
1. Turn ignition switch OFF.
2. Disconnect 15A fuse.
3. Check 15A fuse.
OK or NG
OK >> GO TO 7.
NG >> Replace fuse.
PBIB1572E
Voltage: Battery voltage should exist for 1 sec-
ond after ignition switch is turned ON.
PBIB0795E