fuse box INFINITI FX35 2005 Service Manual
Page 502 of 4731
TROUBLE DIAGNOSIS ATC-65
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2005 July 2005 FX
1. CHECK POWER SUPPLY CIRCUIT FOR UNIFIED METER AND A/C AMP.
1. Disconnect unified meter and A/C amp. connector.
2. Check voltage between unified meter and A/C amp. harness connector M56 terminals 21 (R/W), 22 (G/R) and 35 (LG/R), uni-
fied meter and A/C amp. harness connector M57 terminal 46 (L/
W) and ground.
OK or NG
OK >> GO TO 2.
NG >> Check 10 A and 15 A fuses [Nos. 6, 10, 11, 12 and 19, located in the fuse block (J/B)]. Refer to
PG-82, "
FUSE BLOCK - JUNCTION BOX (J/B)" .
If fuses are OK, check harness for open circuit. Repair or replace if necessary.
If fuses are NG, replace fuse and check harness for short circuit. Repair or replace if necessary.
2. CHECK GROUND CIRCUIT FOR UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF.
2. Check continuity between unified meter and A/C amp. harness connector M56 terminal 29 (B), 30 (B) and ground.
OK or NG
OK >> Replace unified meter and A/C amp.
NG >> Repair harness or connector.
Terminals Ignition switch position
(+)
(-) OFF ACC ON
Unified
meter and A/C amp.
connector Terminal No.
(wire color)
M56 21 (R/W)
Ground Battery volt-
age Battery volt-
age Battery
voltage
M56 22 (G/R) Approx. 0 V Approx. 0 V Battery
voltage
M56 35 (LG/R) Approx. 0 V Battery volt-
age Battery
voltage
M57 46 (L/W) Approx. 0 V Battery volt-
age Battery
voltage
RJIA1984E
29, 30 – Ground : Continuity should exist.
RJIA1985E
Page 519 of 4731
ATC-82
TROUBLE DIAGNOSIS
Revision: 2005 July 2005 FX
1. CHECK POWER SUPPLY FOR BLOWER MOTOR
1. Disconnect blower motor connector.
2. Turn ignition switch ON.
3. Check voltage between blower motor harness connector M78 terminal 1 (L/W) and ground.
OK or NG
OK >> GO TO 2.
NG >> Check power supply circuit and 15 A fuses [Nos. 10 and 11, located in the fuse block (J/B)]. Refer to PG-82,
"FUSE BLOCK - JUNCTION BOX (J/B)" .
If fuses are OK, check harness for open circuit. Repair or replace if necessary.
If fuses are NG, replace fuse and check harness for short circuit. Repair or replace if necessary.
2. CHECK BLOWER MOTOR GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between blower motor harness connector M78 terminal 3 (B) and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair harness or connector.
3. CHECK CIRCUIT CONTINUITY BETWEEN BLOWER MOTOR AND UNIFIED METER AND A/C AMP.
1. Disconnect unified meter and A/C amp. connector.
2. Check continuity between blower motor harness connector M78 terminal 2 (G) and unified meter and A/C amp. harness connec-
tor M57 terminal 53 (G).
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector. 1 – Ground : Battery voltage
RJIA1997E
3 – Ground : Continuity should exist.
RJIA1998E
2 – 53 : Continuity should exist.
RJIA1999E
Page 535 of 4731
ATC-98
TROUBLE DIAGNOSIS
Revision: 2005 July 2005 FX
Low-pressure Side Sometimes Becomes Negative
Low-pressure Side Becomes Negative
DIAGNOSIS PROCEDURE FOR INSUFFICIENT COOLING
SYMPTOM: Insufficient cooling
1. CHECK POWER SUPPLY FOR ECV (ELECTRONIC CONTROL VALVE)
1. Disconnect compressor (ECV) connector.
2. Turn ignition switch ON.
3. Check voltage between compressor (ECV) harness connector F6 terminal 2 (G) and ground.
OK or NG
OK >> GO TO 2.
NG >> Check power supply circuit and 10 A fuse [No. 12, located in the fuse block (J/B)]. Refer to PG-82, "
FUSE
BLOCK - JUNCTION BOX (J/B)" .
If fuse is OK, check harness for open circuit. Repair or replace if necessary.
If fuse is NG, replace fuse and check harness for short circuit. Repair or replace if necessary.
Gauge indication Refrigerant cycle Probable cause Corrective action
Low-pressure side sometimes
becomes negative.
Air conditioning system
does not function and does
not cyclically cool the com-
partment air.
The system constantly func-
tions for a certain period of
time after compressor is
stopped and restarted. Refrigerant does not dis-
charge cyclically.
↓
Moisture is frozen at expan-
sion valve outlet and inlet.
↓
Water is mixed with refriger-
ant.
Drain water from refrigerant
or replace refrigerant.
Replace liquid tank.
AC354A
Gauge indication Refrigerant cycle Probable cause Corrective action
Low-pressure side becomes nega-
tive.
Liquid tank or front/rear side of
expansion valve’s pipe is
frosted or dewed. High-pressure side is closed
and refrigerant does not flow.
↓
Expansion valve or liquid tank
is frosted. Leave the system at rest until
no frost is present. Start it
again to check whether or not
the malfunction is caused by
water or foreign particles.
If water is the cause, initially
cooling is okay. Then the
water freezes causing a
blockage. Drain water from
refrigerant or replace refrig-
erant.
If due to foreign particles,
remove expansion valve
and remove the particles
with dry and compressed air
(not shop air).
If either of the above meth-
ods cannot correct the mal-
function, replace expansion
valve.
Replace liquid tank.
Check lubricant for contami-
nation.
AC362A
2 – ground : Battery voltage
RJIA2294E
Page 656 of 4731
INTEGRATED DISPLAY SYSTEM AV-57
C
D E
F
G H
I
J
L
M A
B
AV
Revision: 2005 July 2005 FX
INTEGRATED DISPLAY SYSTEMPFP:28090
System DescriptionAKS005U0
A/C AND AV SWITCH SYSTEM
Refer to Owner′s Manual for A/C and AV switch operating instructions.
Using the A/C and AV switch at the center of the instrument panel, the controls of the following systems are
centralized:
Integrated display system (Drive computer, setting screen, etc.)
Auto A/C system
Audio system
PRECAUTION OF LCD MONITOR
In order to use LED for backlight of a display, by interior temperature, brightness may change. In low tem-
perature, the refreshing rate of the picture also becomes low because of the low response of the LCD
monitor. When the interior becomes warm, however, the LCD recovers the normal display.
Backlight sometimes flickers or darkens according to the wearing out of LCD and the number of times
switched ON and OFF. In this case, display unit should be replaced. (Exchange only of backlight is impos-
sible.)
POWER SUPPLY AND GROUND
Power is supplied at all times
through 15A fuse (No. 32, located in fuse and fusible link box)
to audio unit terminal 6
to display unit terminal 1 and
to A/C and AV switch terminal 1.
When ignition switch is in ACC or ON position, power is supplied
through 10A fuse [No. 6, located in fuse block (J/B)]
to unified meter and A/C amp. terminal 35
to audio unit terminal 10
to display unit terminal 2 and
to A/C and AV switch terminal 2.
When ignition switch is in ON or START position, power is supplied
through 10A fuse [No. 12, located in fuse block (J/B)]
to unified meter and A/C amp. terminal 22 and
to display unit terminal 3.
Ground is supplied
to unified meter and A/C amp. terminals 29, 30
to display unit terminals 6 and 15 and
to A/C and AV switch terminal 5
through body grounds M35, M45 and M85.
Ground is supplied through the case of the audio unit.
Page 837 of 4731
BL-22
POWER DOOR LOCK SYSTEM
Revision: 2005 July 2005 FX
Component Parts and Harness Connector LocationAIS004LO
System DescriptionAIS004LP
Power is supplied at all times
through 50A fusible link (letter M , located in the fuse and fusible link box).
to BCM terminal 55
thought 15A fuse [No. 22, located in the fuse block (J/B)]
to BCM terminal 42
thought 15A fuse [No. 22, located in the fuse block (J/B)]
to key switch terminal 2 (without intelligent key system)
thought 15A fuse [No. 22, located in the fuse block (J/B)].
to key switch and ignition knob switch terminal 3 (with intelligent key system)
When key switch is ON (key is inserted in ignition key cylinder), power is supplied
through key switch terminal 1 (without intelligent key system) or 4 (with intelligent key system).
to BCM terminal 37
When the door is locked or unlocked with power window main switch (door lock and unlock switch), ground is
supplied
to CPU of power window main switch
through power window main switch (door lock and unlock switch) terminal 17
through grounds M35, M45 and M85.
Then power window main switch (door lock and unlock switch) operation signal is supplied.
through power window main switch terminal 14.
to BCM terminal 22
When the door is locked or unlocked with front power window switch (passenger side) (door lock and unlock
switch), ground is supplied
to CPU of front power window switch (passenger side)
through front power window switch (passenger side) (door lock and unlock switch) terminal 11
through grounds M35, M45 and M85.
Then front power window switch (passenger side) (door lock and unlock switch) operation signal is supplied
through front power window switch (passenger side) terminal 16.
to BCM terminal 22
When the door is locked with front door key cylinder switch, ground is supplied
to power window main switch terminal 4
through key cylinder switch terminals 1 and 5
through grounds M35, M45 and M85.
PIIA6412E
Page 856 of 4731
POWER DOOR LOCK SYSTEM BL-41
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
Check BCM Power Supply and Ground CircuitAIS004LY
1. CHECK FUSE AND FUSIBLE LINK
Check 50A fusible link (letter M, located in teh fuse and fusible link box).
Check 15A fuse [No. 22, located in the fuse block (J/B)].
NOTE:
Refer to BL-21, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse, refer to PG-
3, "POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connectors.
3. Check voltage between BCM connectors M4 terminals 42, 55 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace BCM power supply circuit.
3. CHECK GROUND CIRCUIT
Check continuity between BCM connectors M4 terminals 49, 52 and
ground.
OK or NG
OK >> Power supply and ground circuit are OK.
NG >> Repair or replace BCM ground circuit. 42 (L/R) – Ground : Battery voltage
55 (G) – Ground : Battery voltage
PIIA6374E
49 (B) – Ground : Continuity should exist.
52 (B) – Ground : Continuity should exist.
PIIA6375E
Page 872 of 4731
REMOTE KEYLESS ENTRY SYSTEM BL-57
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
System DescriptionAIS004MB
INPUTS
Power is supplied at all times
to BCM terminal 55
through 50A fusible link (letter M , located in the fuse and fusible link box).
to BCM terminal 42
through 15A fuse (No. 22, located in the fuse and fusible link box).
When the key switch is ON (key is inserted in ignition key cylinder), power is supplied
to BCM terminal 37
through key switch terminal 1 and 2
through 15A fuse (No. 22, located in the fuse and fusible link box).
When the ignition switch is ACC or ON, power is supplied
to BCM terminal 11
through 10A fuse [No. 6, located in the fuse block (J/B)].
When the ignition switch is ON or START, power is supplied
to BCM terminal 38
through 15A fuse [No. 1, located in the fuse block (J/B)].
When the front door switch (driver side) is ON (door is OPEN), ground is supplied
to BCM terminal 62
through front door switch (driver side) terminal 1
through front door switch (driver side) case ground.
When the front door switch (passenger side) is ON (door is OPEN), ground is supplied
to BCM terminal 12
through front door switch (passenger side) terminal 1
through front door switch (passenger side) case ground.
When the rear door switch LH is ON (door is OPEN), ground is supplied
to BCM terminal 63
through rear door switch LH terminal 1
through rear door switch LH case ground.
When the rear door switch RH is ON (door is OPEN), ground is supplied
to BCM meter terminal 13
through rear door switch RH terminal 1
through rear door switch RH case ground.
When the back door switch is ON (door is open), ground is supplied
to BCM terminal 58
through back door closure motor (door switch) terminals 7 and 8
through body grounds B15 and B45
Key fob signal is inputted to remote keyless entry receiver (the antenna of the system is built in remote keyless
entry receiver).
to BCM terminal 20
from remote keyless entry system controls operation of the
The remote keyless entry system controls operation of the
power door lock
hazard and horn reminder
auto door lock
panic alarm
keyless power window down (open)
room lamp and key ring illumination
Page 1004 of 4731
VEHICLE SECURITY (THEFT WARNING) SYSTEM BL-189
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
Canceling the Set Vehicle Security System
When one of the following operations is performed, the armed phase is canceled.
1. Unlock the doors with the key, key fob or Intelligent Key.
2. Turn ignition switch “ON” or “ACC” position.
Canceling the Alarm Operation of the Vehicle Security System
When unlock the door with the key, key fob or Intelligent Key the alarm operation is canceled.
Activating the Alarm Operation of the Vehicle Security System
Make sure the system is in the armed phase. (The security indicator lamp brinks every 2.4 seconds.)
When the following operation 1 or 2 is performed, the system sounds the horns and flashes the headlamps for
about 50 seconds.
1. Hood, back door or any door is opened during armed phase.
2. Disconnecting and connecting the battery connector before canceling armed phase.
POWER SUPPLY
Power is supplied at all times
through 10A fuse [No.19, located in the fuse block (J/B)]
to security indicator lamp terminal 1.
through 50A fusible link (letter M , located in the fuse and fusible link box)
to BCM terminal 55.
through 15A fuse [No.22, located in the fuse block (J/B)]
to BCM terminal 42.
through 15A fuse [No.34, located in the fuse and fusible link box]
to horn relay terminal 2.
through 10A fuse [No.71, located in the IPDM E/R]
to IPDM E/R internal CPU.
through 15A fuse [No.78, located in the IPDM E/R]
to IPDM E/R internal CPU.
With the ignition switch in the ACC or ON position, power is supplied
through 10A fuse [No. 6, located in the fuse block (J/B)]
to BCM terminal 11.
INITIAL CONDITION TO ACTIVATE THE SYSTEM
The operation of the vehicle security system is controlled by the doors, hood and back door.
To activate the vehicle security system, BCM must receive signals indicating the doors, hood and back door
are closed and the doors are locked by key fob, Intelligent Key or ignition key.
When a door is open, BCM terminal 12 (passenger side door), 13 (rear RH door), 62 (driver side door), 63
(rear LH door) receives a ground signal from each door switch.
When front door LH is unlocked by power window main switch (door lock and unlock switch),
BCM terminal 22 receives a signal from terminal 14 of power window main switch with power window serial
link.
When front door RH is unlocked by front power window switch (passenger side) (door lock and unlock switch),
BCM terminal 22 receives a signal from terminal 16 of front power window switch (passenger side) with power
window serial link.
When the hood is open, IPDM E/R receives a ground signal
to IPDM E/R terminal 56
through hood switch terminal 2
through hood switch terminal 1
through body grounds E21, E50 and E51.
The IPDM E/R then sends a signal to the BCM through the CAN SYSTEM.
When the back door is open,
to BCM terminal 58
through back door closure motor terminal 7
Page 1336 of 4731
WARNING CHIME DI-75
C
D E
F
G H
I
J
L
M A
B
DI
Revision: 2005 July 2005 FX
5. CHECK KEY SWITCH CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM harness connector M3 terminal 37 (B/W) and key switch harness connector M23 terminal 1 (B/
W).
3. Check continuity between BCM harness connector M3 terminal 37 (B/W) and ground.
OK or NG
OK >> GO TO 6.
NG >> Repair harness or connector.
6. CHECK KEY SWITCH POWER SUPPLY CIRCUIT
Check voltage between key switch harness connector M23 terminal
2 (L/R) and ground.
OK or NG
OK >> Replace BCM. Refer to BCS-16, "Removal and Installa-
tion of BCM" .
NG >> Check harness between key switch and fuse.
Key Warning Chime Does Not Operate (With Intelligent Key, When Mechanical
Key Is Used)
AKS0079U
1. CHECK FUSE
Check if the key switch and ignition knob switch 10A fuse (No. 38, located in the fuse and fusible link box) is
blown. Refer to DI-63, "
Wiring Diagram — CHIME —" .
Is the fuse blown?
YES >> Replace fuse. Be sure to repair the cause of malfunction before installing new fuse.
NO >> GO TO 2.
2. CHECK WARNING CHIME OPERATION
Check the chime under conditions in exception of key warning chime (when mechanical key is used) opera-
tion.
Does warning chime sound?
YES >> GO TO 3.
NO >> Go to DI-71, "
All Warnings Are Not Operated" or DI-72, "Key Warning Chime and Light Warning
Chime Does Not Operate (Seat Belt Warning Chime Does Operate)" .
37 (B/W) – 1 (B/W) : Continuity should exist.
37 (B/W) – Ground : Continuity should not exist.
PKIB3833E
2 (L/R) – Ground : Battery voltage
SKIA5051E
Page 1365 of 4731
DI-104
LANE DEPARTURE WARNING SYSTEM
Revision: 2005 July 2005 FX
Power Supply and Ground Circuit InspectionAKS00C82
1. CHECK FUSE
Check for blown LDW camera unit fuse.
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse. Refer to PG-
82, "FUSE BLOCK - JUNCTION BOX (J/B)" .
2. CHECK POWER SUPPLY CIRCUIT
Check voltage between LDW camera unit and ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness between LDW camera unit and fuse.
3. CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect LDW camera unit connector.
3. Check continuity between LDW camera unit harness connector R9 terminals 6 (B), 12 (B) and ground.
OK or NG
OK >> Power supply and ground circuit are OK.
NG >> Repair ground harness.
DTC [C1B00] CAMERA UNIT MALFAKS00C7Z
1. CHECK SELF-DIAGNOSIS
1. Perform self-diagnosis.
2. Check if any item other than “[C1B00] CAMERA UNIT” is displayed on self-diagnosis display.
Is any displayed?
YES >> Repair or replace applicable item.
NO >> Replace LDW camera unit.
DTC [C1B01] CAM AIMING INCMPAKS00C80
1. PREFORM CAMERA AIMING ADJUSTMENT
1. Preform camera aiming adjustment. Refer to DI-86, "
Camera Aiming Adjustment" .
2. Erase DTC and perform the LDW camera unit self-diagnosis.
Self
-diagnostic results content
No malfunction detected>>INSPECTION END
Malfunction detected>>Replace LDW camera unit.
Unit Power source Fuse No.
LDW camera unit Ignition switch (ON) 12
Terminals Ignition switch position
(+) (–) OFF ON
Connector Terminal (Wire color)
R9 1 (B/R) Ground 0 V Battery voltage
SKIB1808E
6 (B) – Ground : Continuity should exist.
12 (B) – Ground
SKIB1810E