engine control INFINITI FX35 2007 Service Manual
Page 1572 of 4366
EC-196
[VQ35DE]
DTC P0102, P0103 MAF SENSOR
Revision: 2006 July 2007 FX35/FX45
DTC P0102, P0103 MAF SENSORPFP:22680
Component DescriptionNBS003NC
The mass air flow (MAF) sensor is placed in the stream of intake air.
It measures the intake flow rate by measuring a part of the entire
intake flow. The mass air flow sensor controls the temperature of the
hot wire to a certain amount. The heat generated by the hot wire is
reduced as the intake air flows around it. The more air, the greater
the heat loss.
Therefore, electric current is supplied to hot wire is changed to main-
tain the temperature of the hot wire as air flow increases. The ECM
detects the air flow by means of this current change.
CONSULT-II Reference Value in Data Monitor ModeNBS003ND
Specification data are reference values.
On Board Diagnosis LogicNBS003NE
These self-diagnoses have the one trip detection logic.
FAIL-SAFE MODE
When the malfunction is detected, the ECM enters fail-safe mode and the MIL lights up.
PBIB1604E
MONITOR ITEM CONDITION SPECIFICATION
MAS A/F SE-B1 See EC-137, "
TROUBLE DIAGNOSIS - SPECIFICATION VALUE" .
CAL/LD VALUE
Engine: After warming up
Selector lever: P or N
Air conditioner switch: OFF
No load Idle 5% - 35%
2,500 rpm 5% - 35%
MASS AIRFLOW
Engine: After warming up
Selector lever: P or N
Air conditioner switch: OFF
No load Idle 2.0 - 6.0 g·m/s
2,500 rpm 7.0 - 20.0 g·m/s
DTC No. Trouble diagnosis
name DTC detecting condition Possible cause
P0102
0102 Mass air flow sensor
circuit low input An excessively low voltage from the sensor is
sent to ECM.
Harness or connectors
(Mass air flow sensor circuit is open or
shorted.)
Intake air leaks
Mass air flow sensor
P0103
0103 Mass air flow sensor
circuit high input An excessively high voltage from the sensor is
sent to ECM.
Harness or connectors
(Mass air flow sensor circuit is open or
shorted.)
Mass air flow sensor
Detected items Engine operating condition in fail-safe mode
Mass air flow sensor circuit Engine speed will not rise more than 2,400 rpm due to the fuel cut.
Page 1590 of 4366
EC-214
[VQ35DE]
DTC P0122, P0123 TP SENSOR
Revision: 2006 July 2007 FX35/FX45
DTC P0122, P0123 TP SENSORPFP:16119
Component DescriptionNBS003NY
Electric throttle control actuator consists of throttle control motor,
throttle position (TP) sensor, etc. The throttle position sensor
responds to the throttle valve movement.
The throttle position sensor has two sensors. These sensors are a
kind of potentiometers which transform the throttle valve position into
output voltage, and emit the voltage signal to the ECM. In addition,
these sensors detect the opening and closing speed of the throttle
valve and feed the voltage signals to the ECM. The ECM judges the
current opening angle of the throttle valve from these signals and the
ECM controls the throttle control motor to make the throttle valve
opening angle properly in response to driving condition.
CONSULT-II Reference Value in Data Monitor ModeNBS003NZ
Specification data are reference values.
*: Throttle position sensor 2 signal is converted by ECM internally. Thus, it differs from ECM terminal voltage signal.
On Board Diagnosis LogicNBS003O0
These self-diagnoses have the one trip detection logic.
FAIL-SAFE MODE
When the malfunction is detected, ECM enters fail-safe mode and the MIL lights up.
PBIB0145E
MONITOR ITEM CONDITION SPECIFICATION
THRTL SEN 1
THRTL SEN 2*
Ignition switch: ON
(Engine stopped)
Selector lever: D Accelerator pedal: Fully released More than 0.36V
Accelerator pedal: Fully depressed Less than 4.75V
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0122
0122 Throttle position sensor
2 circuit low input An excessively low voltage from the TP sensor
2 is sent to ECM.
Harness or connectors
(TP sensor 2 circuit is open or shorted.)
(APP sensor 2 circuit is shorted.)
Electric throttle control actuator
(TP sensor 2)
Accelerator pedal position sensor
(APP sensor 2)
P0123
0123 Throttle position sensor
2 circuit high input An excessively high voltage from the TP sen-
sor 2 is sent to ECM.
Engine operation condition in fail-safe mode
The ECM controls the electric throttle control actuator in regulating the throttle opening in order for the idle position to be within +10
degrees.
The ECM regulates the opening speed of the throttle valve to be slower than the normal condition.
So, the acceleration will be poor.
Page 1597 of 4366
DTC P0125 ECT SENSOR EC-221
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC P0125 ECT SENSORPFP:22630
Component DescriptionNBS003O6
NOTE:
If DTC P0125 is displayed with P0117 or P0118, first perform the trouble diagnosis for DTC P0117 or
P0118. Refer to EC-209, "
DTC P0117, P0118 ECT SENSOR" .
The engine coolant temperature (ECT) sensor is used to detect the
engine coolant temperature. The sensor modifies a voltage signal
from the ECM. The modified signal returns to the ECM as the engine
coolant temperature input. The sensor uses a thermistor which is
sensitive to the change in temperature. The electrical resistance of
the thermistor decreases as temperature increases.
<Reference data>
*: This data is reference values and is measured between ECM terminal 73 (Engine
coolant temperature sensor) and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
On Board Diagnosis LogicNBS003O7
SEF594K
Engine coolant
temperature °C ( °F) Voltage* V Resistance k
Ω
-10 (14) 4.4 7.0 - 11.4s 20 (68) 3.5 2.1 - 2.9
50 (122) 2.2 0.68 - 1.00
90 (194) 0.9 0.236 - 0.260
SEF012P
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0125
0125 Insufficient engine cool-
ant temperature for
closed loop fuel control
Voltage sent to ECM from the sensor is not
practical, even when some time has passed
after starting the engine.
Engine coolant temperature is insufficient for
closed loop fuel control.
Harness or connectors
(High resistance in the circuit)
Engine coolant temperature sensor
Thermostat
Page 1605 of 4366
DTC P0130, P0150 A/F SENSOR 1 EC-229
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC P0130, P0150 A/F SENSOR 1PFP:22693
Component DescriptionNBS003VV
The air fuel ratio (A/F) sensor is a planar dual-cell limit current sen-
sor. The sensor element of the air fuel ratio (A/F) sensor is the com-
bination of a Nernst concentration cell (sensor cell) with an oxygen-
pump cell, which transports ions. It has a heater in the element.
The sensor is capable of precise measurement = 1, but also in the
lean and rich range. Together with its control electronics, the sensor
outputs a clear, continuous signal throughout a wide range (0.7 < < air).
The exhaust gas components diffuse through the diffusion gap at the
electrode of the oxygen pump and Nernst concentration cell, where
they are brought to thermodynamic balance.
An electronic circuit controls the pump current through the oxygen-
pump cell so that the composition of the exhaust gas in the diffusion
gap remains constant at = 1. Therefore, the air fuel ratio (A/F) sen-
sor is able to indicate air/fuel ratio by this pumping of current. In
addition, a heater is integrated in the sensor to ensure the required
operating temperature of 700 - 800 °C (1,292 - 1,472 °F).
CONSULT-II Reference Value in Data Monitor ModeNBS003VW
Specification data are reference values.
On Board Diagnosis LogicNBS006SH
To judge the malfunction, the diagnosis checks that the A/F signal computed by ECM from the air fuel ratio (A/
F) sensor 1 signal fluctuates according to fuel feedback control.
DTC Confirmation ProcedureNBS006SI
Perform PROCEDURE FOR MALFUNCTION A first.
If the DTC cannot be confirmed, perform PROCEDURE FOR MALFUNCTION B.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11V at idle.
PROCEDURE FOR MALFUNCTION A
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
SEF579Z
SEF580Z
MONITOR ITEM CONDITION SPECIFICATION
A/F SEN1 (B1)
A/F SEN1 (B2)
Engine: After warming up Maintaining engine speed at
2,000 rpm Fluctuates around 1.5V
DTC No. Trouble diagnosis name DTC detecting condition Possible Cause
P0130
0130
(Bank 1) Air fuel ratio (A/F) sensor 1
circuit A)
The A/F signal computed by ECM from the A/F
sensor 1 signal is constantly in the range other
than approx. 1.5V.
Harness or connectors
(The A/F sensor 1 circuit is open
or shorted.)
Air fuel ratio (A/F) sensor 1
P0150
0150
(Bank 2) B)
The A/F signal computed by ECM from the A/F
sensor 1 signal is constantly approx. 1.5V.
Page 1615 of 4366
DTC P0131, P0151 A/F SENSOR 1 EC-239
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC P0131, P0151 A/F SENSOR 1PFP:22693
Component DescriptionNBS003V3
The air fuel ratio (A/F) sensor is a planar dual-cell limit current sen-
sor. The sensor element of the air fuel ratio (A/F) sensor is the com-
bination of a Nernst concentration cell (sensor cell) with an oxygen-
pump cell, which transports ions. It has a heater in the element.
The sensor is capable of precise measurement = 1, but also in the
lean and rich range. Together with its control electronics, the sensor
outputs a clear, continuous signal throughout a wide range (0.7 < < air).
The exhaust gas components diffuse through the diffusion gap at the
electrode of the oxygen pump and Nernst concentration cell, where
they are brought to thermodynamic balance.
An electronic circuit controls the pump current through the oxygen-
pump cell so that the composition of the exhaust gas in the diffusion
gap remains constant at = 1. Therefore, the air fuel ratio (A/F) sen-
sor is able to indicate air/fuel ratio by this pumping of current. In
addition, a heater is integrated in the sensor to ensure the required
operating temperature of 700 - 800 °C (1,292 - 1,472 °F).
CONSULT-II Reference Value in Data Monitor ModeNBS003V4
Specification data are reference values.
On Board Diagnosis LogicNBS003V5
To judge the malfunction, the diagnosis checks that the A/F signal computed by ECM from the air fuel ratio (A/
F) sensor 1 signal is not inordinately low.
SEF579Z
SEF580Z
MONITOR ITEM CONDITION SPECIFICATION
A/F SEN1 (B1)
A/F SEN1 (B2)
Engine: After warming up Maintaining engine speed at
2,000 rpm Fluctuates around 1.5V
DTC No. Trouble diagnosis name DTC detecting condition Possible Cause
P0131
0131
(Bank 1) Air fuel ratio (A/F) sensor 1
circuit low voltage The A/F signal computed by ECM from the air
fuel ratio (A/F) sensor 1 signal is constantly
approx. 0V.
Harness or connectors
[Air fuel ratio (A/F) sensor 1 circuit
is open or shorted.]
Air fuel ratio (A/F) sensor 1
P0151
0151
(Bank 2)
Page 1624 of 4366
EC-248
[VQ35DE]
DTC P0132, P0152 A/F SENSOR 1
Revision: 2006 July 2007 FX35/FX45
DTC P0132, P0152 A/F SENSOR 1PFP:22693
Component DescriptionNBS003VA
The air fuel ratio (A/F) sensor is a planar dual-cell limit current sen-
sor. The sensor element of the air fuel ratio (A/F) sensor is the com-
bination of a Nernst concentration cell (sensor cell) with an oxygen-
pump cell, which transports ions. It has a heater in the element.
The sensor is capable of precise measurement = 1, but also in the
lean and rich range. Together with its control electronics, the sensor
outputs a clear, continuous signal throughout a wide range (0.7 < < air).
The exhaust gas components diffuse through the diffusion gap at the
electrode of the oxygen pump and Nernst concentration cell, where
they are brought to thermodynamic balance.
An electronic circuit controls the pump current through the oxygen-
pump cell so that the composition of the exhaust gas in the diffusion
gap remains constant at = 1. Therefore, the air fuel ratio (A/F) sen-
sor is able to indicate air/fuel ratio by this pumping of current. In
addition, a heater is integrated in the sensor to ensure the required
operating temperature of 700 - 800 °C (1,292 - 1,472 °F).
CONSULT-II Reference Value in Data Monitor ModeNBS003VB
Specification data are reference values.
On Board Diagnosis LogicNBS003VC
To judge the malfunction, the diagnosis checks that the A/F signal computed by ECM from the air fuel ratio (A/
F) sensor 1 signal is not inordinately high.
SEF579Z
SEF580Z
MONITOR ITEM CONDITION SPECIFICATION
A/F SEN1 (B1)
A/F SEN1 (B2)
Engine: After warming up Maintaining engine speed at
2,000 rpm Fluctuates around 1.5V
DTC No. Trouble diagnosis name DTC detecting condition Possible Cause
P0132
0132
(Bank 1) Air fuel ratio (A/F) sensor 1
circuit high voltage The A/F signal computed by ECM from the air
fuel ratio (A/F) sensor 1 signal is constantly
approx. 5V.
Harness or connectors
[Air fuel ratio (A/F) sensor 1 circuit
is open or shorted.]
Air fuel ratio (A/F) sensor 1
P0152
0152
(Bank 2)
Page 1633 of 4366
DTC P0133, P0153 A/F SENSOR 1 EC-257
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC P0133, P0153 A/F SENSOR 1PFP:22693
Component DescriptionNBS003W3
The air fuel ratio (A/F) sensor 1 is a planar dual-cell limit current sen-
sor. The sensor element of the air fuel ratio (A/F) sensor 1 is the
combination of a Nernst concentration cell (sensor cell) with an oxy-
gen-pump cell, which transports ions. It has a heater in the element.
The sensor is capable of precise measurement = 1, but also in the
lean and rich range. Together with its control electronics, the sensor
outputs a clear, continuous signal throughout a wide range (0.7 < < air).
The exhaust gas components diffuse through the diffusion gap at the
electrode of the oxygen pump and Nernst concentration cell, where
they are brought to thermodynamic balance.
An electronic circuit controls the pump current through the oxygen-
pump cell so that the composition of the exhaust gas in the diffusion
gap remains constant at = 1. Therefore, the air fuel ratio (A/F) sen-
sor 1 is able to indicate air/fuel ratio by this pumping of current. In
addition, a heater is integrated in the sensor to ensure the required
operating temperature of 700 - 800 °C (1,292 - 1,472 °F).
CONSULT-II Reference Value in Data Monitor ModeNBS003W4
Specification data are reference values.
On Board Diagnosis LogicNBS003W5
To judge the malfunction of air fuel ratio (A/F) sensor 1, this diagnosis measures response time of the A/F sig-
nal computed by ECM from the air fuel ratio (A/F) sensor 1 signal. The time is compensated by engine operat-
ing (speed and load), fuel feedback control constant, and the air fuel ratio (A/F) sensor 1 temperature index.
Judgment is based on whether the compensated time (the A/F signal cycling time index) is inordinately long or
not.
SEF579Z
SEF580Z
MONITOR ITEM CONDITION SPECIFICATION
A/F SEN1 (B1)
A/F SEN1 (B2)
Engine: After warming up Maintaining engine speed at
2,000 rpm Fluctuates around 1.5V
DTC No. Trouble diagnosis name DTC detecting condition Possible Cause
P0133
0133
(Bank 1)
Air fuel ratio (A/F) sensor 1
circuit slow response The response of the A/F signal computed by
ECM from air fuel ratio (A/F) sensor 1 signal
takes more than the specified time.
Harness or connectors
[Air fuel ratio (A/F) sensor 1 circuit
is open or shorted.]
Air fuel ratio (A/F) sensor 1
Air fuel ratio (A/F) sensor 1 heater
Fuel pressure
Fuel injector
Intake air leaks
Exhaust gas leaks
PCV
Mass air flow sensor
P0153
0153
(Bank 2)
Page 1641 of 4366
DTC P0133, P0153 A/F SENSOR 1 EC-265
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
5. CLEAR THE SELF-LEARNING DATA
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “SELF-LEARNING CONT” in “WORK SUPPORT” mode with CONSULT-II.
3. Clear the self-learning control coefficient by touching “CLEAR” or “START”.
4. Run engine for at least 10 minutes at idle speed. Is the 1st trip DTC P0171, P172, P0174 or P0175 detected?
Is it difficult to start engine?
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF.
3. Disconnect mass air flow sensor harness connector.
4. Restart engine and let it idle for at least 5 seconds.
5. Stop engine and reconnect mass air flow sensor harness con- nector.
6. Make sure DTC P0102 is displayed.
7. Erase the DTC memory. Refer to EC-66, "
HOW TO ERASE
EMISSION-RELATED DIAGNOSTIC INFORMATION" .
8. Make sure DTC P0000 is displayed.
9. Run engine for at least 10 minutes at idle speed. Is the 1st trip DTC P0171, P0172, P0174 or P0175 detected?
Is it difficult to start engine?
Ye s o r N o
Yes >> Perform trouble diagnosis for DTC P0171, P0174 or P0172, P0175. Refer to EC-304, "DTC
P0171, P0174 FUEL INJECTION SYSTEM FUNCTION" or EC-316, "DTC P0172, P0175 FUEL
INJECTION SYSTEM FUNCTION" .
No >> GO TO 6.
SEF968Y
PBIB1565E
Page 1645 of 4366
DTC P0137, P0157 HO2S2 EC-269
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC P0137, P0157 HO2S2PFP:226A0
Component DescriptionNBS003TZ
The heated oxygen sensor 2 (HO2S2), after three way catalyst 1,
monitors the oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the air fuel ratio (A/F) sensor 1
are shifted, the air-fuel ratio is controlled to stoichiometric, by the sig-
nal from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
CONSULT-II Reference Value in Data Monitor ModeNBS003U0
Specification data are reference values.
On Board Diagnosis LogicNBS003U1
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the air fuel ratio (A/F) sensor 1. The oxy-
gen storage capacity of the three way catalyst 1 causes the longer
switching time. To judge the malfunctions of heated oxygen sensor
2, ECM monitors whether the maximum voltage of the sensor is suf-
ficiently high during the various driving condition such as fuel-cut.
SEF327R
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 (B1)
HO2S2 (B2)
Revving engine from idle to 3,000 rpm quickly after the following condi-
tions are met
–Engine: After warming up
–Keeping the engine speed between 3,500 and 4,000 rpm for 1 minute and
at idle for 1 minute under no load 0 - 0.3V
←→ Approx. 0.6 -
1.0V
HO2S2 MNTR(B1)
HO2S2 MNTR(B2) LEAN
←→ RICH
SEF259VA
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0137
0137
(Bank 1)
Heated oxygen sensor
2 circuit low voltage The maximum voltage from the sensor is not
reached to the specified voltage.
Harness or connectors
(Heated oxygen sensor 2 circuit is open
or shorted)
Heated oxygen sensor 2
Fuel pressure
Fuel injector
Intake air leaks
P0157
0157
(Bank 2)
Page 1652 of 4366
EC-276
[VQ35DE]
DTC P0137, P0157 HO2S2
Revision: 2006 July 2007 FX35/FX45
2. CLEAR THE SELF-LEARNING DATA
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “SELF-LEARNING CONT” in “WORK SUPPORT” mode with CONSULT-II.
3. Clear the self-learning control coefficient by touching “CLEAR”.
4. Run engine for at least 10 minutes at idle speed. Is the 1st trip DTC P0171 or P0174 detected?
Is it difficult to start engine?
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF.
3. Disconnect mass air flow sensor harness connector, and restart and run engine for at least 5 seconds at idle speed.
4. Stop engine and reconnect mass air flow sensor harness con- nector.
5. Make sure DTC P0102 is displayed.
6. Erase the DTC memory. Refer to EC-66, "
HOW TO ERASE
EMISSION-RELATED DIAGNOSTIC INFORMATION" .
7. Make sure DTC P0000 is displayed.
8. Run engine for at least 10 minutes at idle speed. Is the 1st trip DTC P0171 or P0174 detected?
Is it difficult to start engine?
Ye s o r N o
Yes >> Perform trouble diagnosis for DTC P0171or P0174. Refer to EC-304, "DTC P0171, P0174 FUEL
INJECTION SYSTEM FUNCTION" .
No >> GO TO 3.
3. CHECK HEATED OXYGEN SENSOR 2 GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect heated oxygen sensor 2 harness connector.
3. Disconnect ECM harness connector.
4. Check harness continuity between HO2S2 terminal 1 and ECM terminal 78.
Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
SEF968Y
PBIB1565E
Continuity should exist.
PBIB1576E