check engine INFINITI FX35 2007 Service Manual

Page 2696 of 4366

EC-1320
[VK45DE]
FUEL PUMP
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureNBS004H7
1. CHECK OVERALL FUNCTION
1. Turn ignition switch ON.
2. Pinch fuel feed hose (1) with two fingers.
OK or NG
OK >> INSPECTION END
NG >> GO TO 2.
2. CHECK FUEL PUMP POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Turn ignition switch ON.
4. Check voltage between ECM terminal 113 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 3.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
11 3 G Y / R F u e l p u m p r e l a y [Ignition switch: ON]
For 1 second after turning ignition switch ON
[Engine is running] 0 - 1.5V
[Ignition switch: ON]
More than 1 second after turning ignition
switch ON BATTERY VOLTAGE
(11 - 14V)
Fuel pressure pulsation should be felt on the fuel feed
hose for 1 second after ignition switch is turned ON.
PBIB3245E
Voltage: Battery voltage
PBIB1187E

Page 2698 of 4366

EC-1322
[VK45DE]
FUEL PUMP
Revision: 2006 July 2007 FX35/FX45
6. CHECK 15A FUSE
1. Turn ignition switch OFF.
2. Disconnect 15A fuse.
3. Check 15A fuse.
OK or NG
OK >> GO TO 7.
NG >> Replace fuse.
7. CHECK FUEL PUMP POWER SUPPLY CIRCUIT-IV
1. Disconnect IPDM E/R harness connector E8.
2. Check harness continuity between IPDM E/R terminal 39 and “fuel level sensor unit and fuel pump” termi- nal 1.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 11.
NG >> GO TO 8.
8. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E206, B6
Harness for open or short between IPDM E/R and “fuel level sensor unit and fuel pump”
>> Repair harness or connectors.
9. CHECK FUEL PUMP GROUND CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between “fuel level sensor unit and fuel pump” terminal 3 and ground. Refer to Wiring Diagram.
2. Also check harness for short to power.
OK or NG
OK >> GO TO 10.
NG >> Repair open circuit or short to power in harness or connectors.
10. CHECK FUEL PUMP
Refer to EC-1323, "
Component Inspection" .
OK or NG
OK >> GO TO 11.
NG >> Replace fuel pump.
11 . CHECK INTERMITTENT INCIDENT
Refer to EC-812, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> Replace IPDM E/R. Refer to PG-17, "IPDM E/R (INTELLIGENT POWER DISTRIBUTION MOD-
ULE ENGINE ROOM)" .
NG >> Repair or replace harness or connectors. Continuity should exist.
Continuity should exist.

Page 2714 of 4366

EC-1338
[VK45DE]
IGNITION SIGNAL
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureNBS004GV
1. CHECK ENGINE START
Turn ignition switch OFF, and restart engine.
Is engine running?
Ye s o r N o
Yes (With CONSULT-II)>>GO TO 2.
Yes (Without CONSULT-II)>>GO TO 3.
No >> GO TO 4.
2. CHECK OVERALL FUNCTION
With CONSULT-II
1. Perform “POWER BALANCE” in “ACTIVE TEST” mode with CONSULT-II.
2. Make sure that each circuit produces a momentary engine speed drop.
OK or NG
OK >> INSPECTION END
NG >> GO TO 10.
TER-
MINAL
NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
65
79
80
81 P
LG
GY
G Ignition signal No. 8
Ignition signal No. 6
Ignition signal No. 4
Ignition signal No. 2 [Engine is running]
Warm-up condition
Idle speed
NOTE:
The pulse cycle changes depending on rpm
at idle 0 - 0.2V
[Engine is running]
Warm-up condition
Engine speed: 2,000 rpm 0.1 - 0.4V
PBIB0044E
PBIB0045E
PBIB0133E

Page 2715 of 4366

IGNITION SIGNAL EC-1339
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
3. CHECK OVERALL FUNCTION
Without CONSULT-II
1. Let engine idle.
2. Read the voltage signal between ECM terminals 46, 60, 61, 62, 65, 79, 80, 81 and ground with an oscilloscope.
3. Verify that the oscilloscope screen shows the signal wave as shown below.
NOTE:
The pulse cycle changes depending on rpm at idle.
OK or NG
OK >> INSPECTION END
NG >> GO TO 10.
4. CHECK IGNITION COIL POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF, wait at least 10 seconds and then turn ON.
2. Check voltage between ECM terminals 119, 120 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> Go to EC-813, "
POWER SUPPLY AND GROUND CIR-
CUIT" .
PBIB2094E
PBIB0044E
Voltage: Battery voltage
MBIB0034E

Page 2719 of 4366

IGNITION SIGNAL EC-1343
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Component InspectionNBS004GW
IGNITION COIL WITH POWER TRANSISTOR
CAUTION:
Do the following procedure in the place where ventilation is good without the combustible.
1. Turn ignition switch OFF.
2. Disconnect ignition coil harness connector.
3. Check resistance between ignition coil terminals as follows.
4. If NG, replace ignition coil with power transistor. If OK, go to next step.
5. Turn ignition switch OFF.
6. Reconnect all harness connectors disconnected.
7. Remove fuel pump fuse in IPDM E/R to release fuel pressure.
NOTE:
Do not use CONSULT-II to release fuel pressure, or fuel pres-
sure applies again during the following procedure.
8. Start engine.
9. After engine stalls, crank it two or three times to release all fuel pressure.
10. Turn ignition switch OFF.
11. Remove all ignition coil harness connectors to avoid the electri- cal discharge from the ignition coils.
12. Remove ignition coil and spark plug of the cylinder to be checked.
13. Crank engine for five seconds or more to remove combustion gas in the cylinder.
14. Connect spark plug and harness connector to ignition coil.
15. Fix ignition coil using a rope etc. with gap of 13 - 17 mm between the edge of the spark plug and grounded metal portion
as shown in the figure.
16. Crank engine for about three seconds, and check whether spark is generated between the spark plug and the grounded metal
portion.
CAUTION:
Do not approach to the spark plug and the ignition coil
within 50cm. Be careful not to get an electrical shock
while checking, because the electrical discharge voltage
becomes 20kV or more.
It might cause to damage the ignition coil if the gap of more than 17 mm is taken.
NOTE:
When the gap is less than 13 mm, the spark might be generated even if the coil is malfunctioning.
17. If NG, replace ignition coil with power transistor.
CONDENSER
1. Turn ignition switch OFF.
2. Disconnect condenser harness connector.
Terminal No. (Polarity) Resistance Ω [at 25 °C (77 °F)]
1 and 2 Except 0 or ∞
1 and 3 Except 0
2 and 3
Spark should be generated.
PBIB0847E
PBIB1482E
PBIB2325E

Page 2723 of 4366

REFRIGERANT PRESSURE SENSOR EC-1347
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureNBS004HC
1. CHECK REFRIGERANT PRESSURE SENSOR OVERALL FUNCTION
1. Start engine and warm it up to normal operating temperature.
2. Turn A/C switch and blower fan switch ON.
3. Check voltage between ECM terminal 70 and ground with CON- SULT-II or tester.
OK or NG
OK >> INSPECTION END
NG >> GO TO 2.
2. CHECK GROUND CONNECTIONS
1. Turn A/C switch and blower fan switch OFF.
2. Turn ignition switch OFF.
3. Loosen and retighten three ground screws on the body. Refer to EC-819, "
Ground Inspection" .
OK or NG
OK >> GO TO 3.
NG >> Repair or replace ground connections.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
49 PU Sensor power supply
(Refrigerant pressure sen-
sor) [Ignition switch: ON]
Approximately 5V
67 B/W Sensor ground [Engine is running]
Warm-up condition
Idle speed Approximately 0V
70 L/R Refrigerant pressure sensor [Engine is running]
Warm-up condition
Both A/C switch and blower fan motor
switch: ON (Compressor operates) 1.0 - 4.0V
Voltage: 1.0 - 4.0V
PBIB1188E
PBIB2195E

Page 2728 of 4366

EC-1352
[VK45DE]
SNOW MODE SWITCH
Revision: 2006 July 2007 FX35/FX45
Diagnostic ProcedureNBS004HY
1. CHECK SNOW MODE SWITICH OVERALL FUNCTION-I
1. Turn ignition switch ON.
2. Select “SNOW MODE SW” in “DATA MONITOR” mode with CONSULT-II.
3. Check “SNOW MODE SW” indication under the following condi- tions.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. CHECK SNOW MODE SWITICH OVERALL FUNCTION-II
1. Turn ignition switch ON.
2. Start engine.
3. Check the snow indicator lamp under the following condition.
OK or NG
OK >> INSPECTION END
NG >> GO TO 7.
3. CHECK DTC WITH “UNIFIED METER AND A/C AMP.”
Refer to DI-31, "
SELF-DIAG RESULTS" .
OK or NG
OK >> GO TO 4.
NG >> Go to DI-28, "
UNIFIED METER AND A/C AMP" .
4. CHECK SNOW MODE SWITCH POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect snow mode switch harness connector.
3. Turn ignition switch ON.
4. Check voltage between snow mode switch terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
CONDITION INDICATION
Snow mode switch: ON ON
Snow mode switch: OFF OFF
PBIB2009E
CONDITION INDICATOR LAMP
Snow mode switch: ON Illuminated
Snow mode switch: OFF Not illuminated
Voltage: Battery voltage.
PBIB2562E

Page 2735 of 4366

VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS) EC-1359
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Diagnostic ProcedureNBS004GQ
1. CHECK OVERALL FUNCTION
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode with CON- SULT-II.
3. Turn VIAS control solenoid valve ON and OFF, and make sure that power valve actuator (1) rod moves.
Without CONSULT-II
1. Lift up the vehicle.
2. Start engine and warm it up to normal operating temperature.
3. Make sure that power valve actuator (1) rod moves when chang- ing the gear position to N and D alternately.
OK or NG
OK >> INSPECTION END
NG (With CONSULT-II)>>GO TO 2.
NG (Without CONSULT-II)>>GO TO 3.
PBIB0844E
PBIB3249E
PBIB3249E

Page 2736 of 4366

EC-1360
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2006 July 2007 FX35/FX45
2. CHECK VACUUM EXISTENCE
With CONSULT-II
1. Stop engine and disconnect vacuum hose connected to power valve actuator.
2. Start engine and let it idle.
3. Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode with CON- SULT-II.
4. Turn VIAS control solenoid valve “ON” and “OFF”, and check vacuum existence under the following conditions.
OK or NG
OK >> Repair or replace power valve actuator.
NG >> GO TO 4.
3. CHECK VACUUM EXISTENCE
Without CONSULT-II
1. Stop engine and disconnect vacuum hose connected to power valve actuator.
2. Disconnect VIAS control solenoid valve (1) harness connector.
–Vacuum tank (2)
3. Start engine and let it idle.
4. Apply 12V of direct current between VIAS control solenoid valve terminals 1 and 2.
5. Check vacuum existence under the following conditions.
OK or NG
OK >> Repair or replace power valve actuator.
NG >> GO TO 4.
VIAS SOL VALVE Vacuum
ON Should exist.
OFF Should not exist.
PBIB0844E
PBIB3236E
Condition Vacuum
12V direct current supply Should exist
No supply Should not exist
PBIB0845E

Page 2737 of 4366

VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS) EC-1361
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
4. CHECK VACUUM HOSE
1. Stop engine.
2. Check hoses and tubes between intake manifold and power valve actuator for crack, clogging, improper connection or dis-
connection. Refer to EC-769, "
Vacuum Hose Drawing" .
OK or NG
OK >> GO TO 5.
NG >> Repair hoses or tubes.
5. CHECK VACUUM TANK
Refer to EC-1362, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace vacuum tank.
6. CHECK VIAS CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect VIAS control solenoid valve (1) harness connector.
–Vacuum tank (2)
3. Turn ignition switch ON.
4. Check voltage between VIAS control solenoid valve terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
SEF109L
PBIB3236E
Voltage: Battery voltage
PBIB0173E

Page:   < prev 1-10 ... 451-460 461-470 471-480 481-490 491-500 501-510 511-520 521-530 531-540 ... 680 next >