14 CHECK MALFUNCTIONING SENSOR
Refer to the following chart for malfunctioning code No.
(If two or more sensors malfunction, corresponding code Nos. blink respectively two times.)
MTBL0083
*1: Conduct self-diagnosis STEP 2 under sunshine.
When conducting indoors, aim a light (more than 60W) at sunload sensor, otherwise Code No.
will indicate despite that
sunload sensor is functioning properly.
*2: HA-129
*3: HA-132
*4: HA-139
*5: HA-135
*6: HA-141
RHA455G
RHA501A
©INSPECTION END
TROUBLE DIAGNOSES
Self-diagnosis (Cont'd)
HA-62

Page 1862 of 2395

15 CHECK MALFUNCTIONING DOOR MOTOR POSITION SWITCH
Mode or (and) intake door motor position switch(es) is (are) malfunctioning.
(If two or more mode or intake doors are out of order, corresponding code numbers blink respectively two times.)
MTBL0508
*1: If mode door motor harness connector is disconnected, the following display pattern will appear.
,,,,,Return to
*2: If intake door motor harness connector is disconnected, the following display pattern will appear.
,,,Return to
*3: HA-75
*4: HA-87
RHA168DA
RHA498A
©INSPECTION END
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
SC
EL
IDX
TROUBLE DIAGNOSES
Self-diagnosis (Cont'd)
HA-63

Page 1863 of 2395

AUXILIARY MECHANISM: TEMPERATURE SETTING TRIMMER=NBHA0021S06With Navigation SystemNBHA0021S0601The trimmer compensates for differences in range of±3ÉC (±6ÉF) between temperature setting (displayed
digitally) and temperature felt by driver.
Operating procedures for this trimmer are as follows:
IBegin Self-diagnosis STEP 5 mode.
IPress
(fan) UP switch to set system in auxiliary mode.
IDisplay shows ª
º in auxiliary mechanism.
It takes approximately 3 seconds.
ITurn the temperature dial clockwise or counterclockwise: Temperature will change at a rate of 0.5ÉC (1ÉF).
RHA863H
When battery cable is disconnected, trimmer operation is canceled. Temperature set becomes that of
initial condition, i.e. 0ÉC (0ÉF).
TROUBLE DIAGNOSES
Self-diagnosis (Cont'd)
HA-64

Page 1864 of 2395

How to Perform Trouble Diagnoses for Quick
and Accurate Repair
=NBHA0018WORK FLOWNBHA0018S01
SHA900E
*1: Operational Check (HA-66)
SYMPTOM TABLENBHA0018S02
Symptom Reference Page
IA/C system does not come on.IGo to Trouble Diagnosis Procedure for A/C system. HA-71
IAir outlet does not change.
IGo to Trouble Diagnosis Procedure for Mode Door Motor. (LAN) HA-75
IMode door motor does not operate nor-
mally.
IDischarge air temperature does not
change.
IGo to Trouble Diagnosis Procedure for Air Mix Door Motor. (LAN) HA-82
IAir mix door motor does not operate nor-
mally.
IIntake door does not change.
IGo to Trouble Diagnosis Procedure for Intake Door Motor. HA-87
IIntake door motor does not operate nor-
mally.
IBlower motor operation is malfunctioning.
IGo to Trouble Diagnosis Procedure for Blower Motor. HA-95
IBlower motor operation is malfunctioning
under out of starting fan speed control.
IMagnet clutch does not engage.IGo to Trouble Diagnosis Procedure for Magnet Clutch. HA-104
IInsufficient cooling.IGo to Trouble Diagnosis Procedure for Insufficient Cooling. HA-112
IInsufficient heating.IGo to Trouble Diagnosis Procedure for Insufficient Heating. HA-121
INoise.IGo to Trouble Diagnosis Procedure for Noise. HA-123
ISelf-diagnosis can not be performed.IGo to Trouble Diagnosis Procedure for Self-diagnosis. HA-124
IMemory function does not operate.IGo to Trouble Diagnosis Procedure for Memory Function. HA-126
IECON mode does not operate.IGo to Trouble Diagnosis Procedure for ECON (ECONOMY) Ð
mode.HA-128
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
SC
EL
IDX
TROUBLE DIAGNOSES
How to Perform Trouble Diagnoses for Quick and Accurate Repair
HA-65

Page 1865 of 2395

Operational CheckNBHA0019The purpose of the operational check is to confirm that the system
operates properly.
CONDITIONS:NBHA0019S01IEngine running and at normal operating temperature.
RHA864H
RHA335HA
PROCEDURE:NBHA0019S021. Check Memory FunctionNBHA0019S02011. Set the temperature 85ÉF or 32ÉC.
2. Press OFF switch.
3. Turn the ignition off.
4. Turn the ignition on.
5. Press the AUTO switch.
6. Confirm that the set temperature remains at previous tempera-
ture.
7. Press OFF switch.
If NG, go to trouble diagnosis procedure for memory function (HA-
126).
If OK, continue with next check.
RHA457GA
RHA329HA
2. Check BlowerNBHA0019S02021. Press fan switch (up side) one time.
Blower should operate on low speed.
The fan symbol should have one blade lit
.
2. Press fan switch (up side) one more time, and continue check-
ing blower speed and fan symbol until all speeds are checked.
3. Leave blower on MAX speed
.
If NG, go to trouble diagnosis procedure for blower motor (HA-95).
If OK, continue with next check.
TROUBLE DIAGNOSES
Operational Check
HA-66

Page 1866 of 2395

RHA865H
RHA330HA
3. Check Discharge AirNBHA0019S02031. Press MODE switch four times and D/F button.
2. Each position indicator should change shape.
RHA654F
3. Confirm that discharge air comes out according to the air dis-
tribution table at left.
Refer to ªDischarge Air Flowº (HA-25).
NOTE:
Confirm that the compressor clutch is engaged (visual inspection)
and intake door position is at FRESH when the DEF
is
selected.
Intake door position is checked in the next step.
If NG, go to trouble diagnosis procedure for mode door motor
(HA-75).
If OK, continue with next check.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
SC
EL
IDX
TROUBLE DIAGNOSES
Operational Check (Cont'd)
HA-67

Page 1867 of 2395

RHA459GA
RHA331HA
4. Check RecirculationNBHA0019S02041. Press RECswitch.
Recirculation indicator should illuminate.
2. Listen for intake door position change (you should hear blower
sound change slightly).
If NG, go to trouble diagnosis procedure for intake door (HA-87).
If OK, continue with next check.
RHA460GA
RHA332HA
5. Check Temperature DecreaseNBHA0019S0205Without Navigation System
1) Press the temperature decrease button until 18ÉC (65ÉF) is
displayed.
2) Check for cold air at discharge air outlets.
If NG, go to trouble diagnosis procedure for insufficient cooling
(HA-112).
If OK, continue with next check.
With Navigation System
ITurn the temperature dial counterclockwise until 18ÉC (65ÉF)
is displayed.
ICheck for cold air at discharge air outlets.
If NG, go to trouble diagnosis procedure for insufficient cooling
(HA-112).
If OK, continue with next check.
TROUBLE DIAGNOSES
Operational Check (Cont'd)
HA-68

Page 1868 of 2395

RHA461GA
SHA278FA
6. Check Temperature IncreaseNBHA0019S0206Without Navigation System
IPress the temperature increase button until 32ÉC (85ÉF) is
displayed.
ICheck for hot air at discharge air outlets.
If NG, go to trouble diagnosis procedure for insufficient heating
(HA-121).
If OK, continue with next check.
With Navigation System
ITurn the temperature dial clockwise until 32ÉC (85ÉF) is dis-
played.
ICheck for hot air at discharge air outlets.
If NG, go to trouble diagnosis procedure for insufficient heating
(HA-121).
If OK, continue with next check.
RHA462GA
RHA333HA
7. Check ECON (Economy) ModeNBHA0019S02071. Set the temperature 75ÉF or 25ÉC.
2. Press ECON switch.
3. Display should indicate ECON (no AUTO).
Confirm that the compressor clutch is not engaged (visual
inspection).
(Discharge air and blower speed will depend on ambient, in-
vehicle and set temperatures.)
If NG, go to trouble diagnosis procedure for ECON (Economy)
mode (HA-128).
If OK, continue with next check.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
SC
EL
IDX
TROUBLE DIAGNOSES
Operational Check (Cont'd)
HA-69

Page 1869 of 2395

RHA463GA
RHA334HA
8. Check AUTO ModeNBHA0019S02081. Press AUTO switch.
2. Display should indicate AUTO (no ECON).
Confirm that the compressor clutch engages (audio or visual
inspection).
(Discharge air and blower speed will depend on ambient, in-
vehicle and set temperatures.)
If NG, go to trouble diagnosis procedure for A/C system (HA-71),
then if necessary, trouble diagnosis procedure for magnet clutch
(HA-104).
SHA286HA
9. Check Ambient Display (With Navigation System)NBHA0019S02091. Press AUTO switch.
2. Press AMB switch.
3. Display should show the outside (ambient) temperature for
approximately 5 seconds.
If NG, go to trouble diagnosis procedure for multiplex communica-
tion circuit (HA-142).
If all operational check are OK (symptom can not be duplicated),
go to ªIncident Simulation Testsº (GI section) and perform tests as
outlined to simulate driving conditions environment. If symptom
appears, refer to ªSymptom Tableº (HA-65) and perform applicable
trouble diagnosis procedures.
TROUBLE DIAGNOSES
Operational Check (Cont'd)
HA-70

Page 1870 of 2395

A/C System
TROUBLE DIAGNOSIS PROCEDURE FOR A/C SYSTEM=NBHA0089SYMPTOM:
IA/C system does not come on.
INSPECTION FLOW
RHA866H
*1: HA-72 *2: HA-66 *3: HA-142
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
SC
EL
IDX
TROUBLE DIAGNOSES
A/C System
HA-71