DTC P1124, P1126 THROTTLE CONTROL MOTOR RELAY
EC-377
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
4. CHECK THROTTLE CONTROL MOTOR RELAY INPUT SIGNAL CIRCUIT-I
1. Check voltage between ECM terminal 3 and ground under the
following conditions with CONSULT-II or tester.
OK or NG
OK >> GO TO 7.
NG >> GO TO 5.
5. CHECK THROTTLE CONTROL MOTOR RELAY INPUT SIGNAL CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Disconnect IPDM E/R harness connector E119.
4. Check continuity between ECM terminal 3 and IPDM E/R terminal 6.
Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E2, F32
Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
7. CHECK INTERMITTENT INCIDENT
Refer to EC-127, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> Replace IPDM E/R. Refer to PG-17, "IPDM E/R (INTELLIGENT POWER DISTRIBUTION MOD-
ULE ENGINE ROOM)" .
NG >> Repair or replace harness or connectors.
Ignition switch Voltage
OFF Approximately 0V
ONBattery voltage
(11 - 14V)
MBIB0028E
Continuity should exist.
Page 1570 of 3371
DTC P1128 THROTTLE CONTROL MOTOR
EC-379
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
Wiring DiagramUBS00H7Y
BBWA11 80 E
Page 1572 of 3371
DTC P1128 THROTTLE CONTROL MOTOR
EC-381
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
2. CHECK THROTTLE CONTROL MOTOR OUTPUT SIGNAL CIRCUIT FOR OPEN OR SHORT
1. Disconnect electric throttle control actuator harness connector.
2. Disconnect ECM harness connector.
3. Check harness continuity between the following terminals.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace.
3. CHECK THROTTLE CONTROL MOTOR
Refer to EC-381, "
Component Inspection" .
OK or NG
OK >> GO TO 4.
NG >> GO TO 5.
4. CHECK INTERMITTENT INCIDENT
Refer to EC-127, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> GO TO 5.
NG >> Repair or replace harness or connectors.
5. REPLACE ELECTRIC THROTTLE CONTROL ACTUATOR
1. Replace the electric throttle control actuator.
2. Perform EC-44, "
Throttle Valve Closed Position Learning" .
3. Perform EC-44, "
Idle Air Volume Learning" .
>>INSPECTION END
Component InspectionUBS00H80
THROTTLE CONTROL MOTOR
1. Disconnect electric throttle control actuator harness connector.
2. Check resistance between terminals 5 and 6.
3. If NG, replace electric throttle control actuator and go to next
step.
4. Perform EC-44, "
Throttle Valve Closed Position Learning" .
5. Perform EC-44, "
Idle Air Volume Learning" .
Electric throttle control
actuator terminalECM terminal Continuity
55 Should not exist
4 Should exist
65 Should exist
4 Should not exist
BBIA0371E
Resistance: Approximately 1 - 15 Ω [at 25 °C (77°F)]
PBIB2066E
Page 1577 of 3371
EC-386Revision: August 2007
DTC P1146, P1166 HO2S2
2004 QX56
Wiring DiagramUBS00H87
BANK 1
BBWA11 58 E
Page 1582 of 3371
DTC P1146, P1166 HO2S2
EC-391
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
3. CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect heated oxygen sensor 2 harness connector.
3. Check harness continuity between HO2S2 terminal 4 and body ground.
Refer to Wiring Diagram.
4. Also check harness for short to power.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F14, E5
Harness for open or short between HO2S2 and body ground
>> Repair open circuit or short to power in harness or connectors. Continuity should exist.
BBIA0435E
Page 1583 of 3371
EC-392Revision: August 2007
DTC P1146, P1166 HO2S2
2004 QX56
5. CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to Wiring Diagram.
3. Check harness continuity between the following terminals and ground.
Refer to Wiring Diagram.
4. Also check harness for short to ground or short to power.
OK or NG
OK >> GO TO 6.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
6. CHECK HEATED OXYGEN SENSOR 2
Refer to EC-392, "
Component Inspection" .
OK or NG
OK >> GO TO 7.
NG >> Replace malfunctioning heated oxygen sensor 2.
7. CHECK INTERMITTENT INCIDENT
Refer to EC-127, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionUBS00H89
HEATED OXYGEN SENSOR 2
With CONSULT-II
1. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
2. Start engine and warm it up to the normal operating tempera-
ture.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and
4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
DTCTe r m i n a l s
Bank
ECM Sensor
P1146 55 1 1
P1166 74 1 2
Continuity should exist.
DTCTe r m i n a l s
Bank
ECM Sensor
P1146 55 1 1
P1166 74 1 2
Continuity should not exist.
SEF 1 74 Y
Page 1589 of 3371
EC-398Revision: August 2007
DTC P1147, P1167 HO2S2
2004 QX56
Wiring DiagramUBS00H8G
BANK 1
BBWA11 58 E
Page 1594 of 3371
DTC P1147, P1167 HO2S2
EC-403
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
3. CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect heated oxygen sensor 2 harness connector.
3. Check harness continuity between HO2S2 terminal 4 and body ground.
Refer to Wiring Diagram.
4. Also check harness for short to power.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F14, E5
Harness for open or short between HO2S2 and body ground
>> Repair open circuit or short to power in harness or connectors. Continuity should exist.
BBIA0435E
Page 1595 of 3371
EC-404Revision: August 2007
DTC P1147, P1167 HO2S2
2004 QX56
5. CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to Wiring Diagram.
3. Check harness continuity between the following terminals and ground.
Refer to Wiring Diagram.
4. Also check harness for short to ground or short to power.
OK or NG
OK >> GO TO 6.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
6. CHECK HEATED OXYGEN SENSOR 2
Refer to EC-404, "
Component Inspection" .
OK or NG
OK >> GO TO 7.
NG >> Replace malfunctioning heated oxygen sensor 2.
7. CHECK INTERMITTENT INCIDENT
Refer to EC-127, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionUBS00H8I
HEATED OXYGEN SENSOR 2
With CONSULT-II
1. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
2. Start engine and warm it up to the normal operating tempera-
ture.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and
4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
DTCTe r m i n a l s
Bank
ECM Sensor
P1147 55 1 1
P1167 74 1 2
Continuity should exist.
DTCTe r m i n a l s
Bank
ECM Sensor
P1147 55 1 1
P1167 74 1 2
Continuity should not exist.
SEF 1 74 Y
Page 1604 of 3371
DTC P1217 ENGINE OVER TEMPERATURE
EC-413
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
Wiring DiagramUBS00H8X
BBWA11 81 E