lock INFINITI QX56 2004 Factory Service Manual

Page 821 of 3371

BL-56
REMOTE KEYLESS ENTRY SYSTEM
Revision: August 20072004 QX56
5. Touch “BCM”.
If "BCM" is not indicated, refer to GI-39, "
CONSULT-II Data Link
Connector (DLC) Circuit" .
6. Touch “MULTI REMOTE ENT”.
7. Select diagnosis mode.
“DATA MONITOR”, “ACTIVE TEST” and “WORK SUPPORT”
are available.
CONSULT-II Application ItemsEIS002RX
“MULTI REMOTE ENT”
Data Monitor
BCIA0030E
LIIA0194E
BCIA0031E
Monitored Item Description
DOOR SW-AS Indicates [ON/OFF] condition of front door switch RH.
DOOR SW-RR Indicates [ON/OFF] condition of rear door switch RH.
DOOR SW-RL Indicates [ON/OFF] condition of rear door switch LH.
DOOR SW-DR Indicates [ON/OFF] condition of front door switch LH.
BACK DOOR SW Indicates [ON/OFF] condition of back door latch.
KEY ON SW Indicates [ON/OFF] condition of key switch.
ACC ON SW Indicates [ON/OFF] condition of ignition switch in ACC position.
IGN ON SW Indicates [ON/OFF] condition of ignition switch in ON position.
KEYLESS PANIC Indicates [ON/OFF] condition of panic signal from keyfob.
KEYLESS UNLOCK Indicates [ON/OFF] condition of unlock signal from keyfob.
KEYLESS LOCK Indicates [ON/OFF] condition of lock signal from keyfob.
KEY CYL LK-SW Indicates [ON/OFF] condition of lock signal from door key cylinder switch.
KEY CYL UN-SW Indicates [ON/OFF] condition of unlock signal from door key cylinder switch.
KEYLESS PBD Indicates [ON/OFF] condition of power back door signal from keyfob.

Page 822 of 3371

REMOTE KEYLESS ENTRY SYSTEM
BL-57
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Active Test
Work Support
CDL UNLOCK SW Indicates [ON/OFF] condition of unlock signal from lock/unlock switch.
CDL LOCK SW Indicates [ON/OFF] condition of lock signal from lock/unlock switch.
DOOR SW-RL Indicates [ON/OFF] condition of rear door switch LH.
DOOR SW-RR Indicates [ON/OFF] condition of rear door switch RH.
RKE LCK-UNLCK Indicates [ON/OFF] condition of lock/unlock signal at the same time from keyfob.
RKE KEEP UNLK Indicates [ON/OFF] condition of unlock signal from keyfob.
TRNK OPN MNTR Indicates [ON/OFF] condition of glass open switch.Monitored Item Description
Test Item Description
FLASHER This test is able to check right and left hazard reminder operation. The right hazard lamp turns on
when “RH” on CONSULT-II screen is touched and the left hazard lamp turns on when "LH" on CON-
SULT-II screen is touched.
POWER WINDOW DOWN This test is able to check power window down operation. The windows are lowered when “ON” on
CONSULT-II screen is touched.
HORN This test is able to check panic alarm and horn reminder operations. The alarm activate for 0.5 sec-
onds after “ON” on CONSULT-II screen is touched.
DOOR LOCK This test is able to check door lock operation. The doors lock and unlock based on the item on CON-
SULT-II screen touched.
TRUNK/BACK DOOR This test is able to check back door actuator operation. The back door is opened when “OPEN” on
CONSULT-II screen is touched.
PSB/PBD OPEN TESTThis test is able to check power back door operation. The power back door is fully opened when
“OPEN” on the CONSULT-II screen is touched if the door operation enable conditions are met.
Test Item Description
REMO CONT ID REGIST Keyfob ID code can be registered.
REMO CONT ID ERASUR Keyfob ID code can be erased.
REMO CONT ID CONFIR It can be checked whether keyfob ID code is registered or not in this mode.
HORN CHIRP SET Horn chirp function mode can be changed in this mode. The function mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
HAZARD LAMP SET Hazard lamp function mode can be changed in this mode. The function mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
MULTI ANSWER BACK SETHazard and horn reminder mode can be changed in this mode. The reminder mode will be changed
when “CHANG SETT” on CONSULT-II screen is touched.
AUTO LOCK SETAuto locking function mode can be changed in this mode. The function mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
PANIC ALRM SETPanic alarm operation mode can be changed in this mode. The operation mode will be changed
when "CHANG SETT" on CONSULT-II screen is touched.
TRUNK OPEN SETBack door opener operation mode can be changed in this mode. The operation mode will be
changed when "CHANG SETT" on CONSULT-II screen is touched.
PW DOWN SETKeyless power window down (open) operation mode can be changed in this mode. The operation
mode will be changed when "CHANG SETT" on CONSULT-II screen is touched.

Page 823 of 3371

BL-58
REMOTE KEYLESS ENTRY SYSTEM
Revision: August 20072004 QX56
Hazard and horn reminder mode
Auto locking function mode
Panic alarm operation mode
Back door open operation mode
Keyless power window down operation mode
MODE 1
(C mode)MODE 2
(S mode)MODE 3MODE 4MODE 5MODE 6
Keyfob
operation Lock Unlock Lock Unlock Lock Unlock Lock Unlock Lock Unlock Lock Unlock
Hazard warning
lamp flashTwiceOnceTwice———TwiceOnceTwice——Once
Horn sound Once———————Once—Once—
MODE 1MODE 2MODE 3
Auto locking function 5 minutes Nothing 1 minute
MODE 1MODE 2MODE 3
Keyfob operation 0.5 seconds Nothing 1.5 seconds
MODE 1MODE 2MODE 3
Keyfob operation 0.5 seconds Nothing 0.5 seconds
MODE 1 MODE 2 MODE 3
Keyfob operation 3 seconds Nothing 5 seconds

Page 824 of 3371

REMOTE KEYLESS ENTRY SYSTEM
BL-59
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Trouble Diagnosis ProcedureEIS002RY
1. Check the symptom and customer's requests.
2. Understand outline of system. Refer to BL-45, "
System Description" .
3. Confirm system operation.
Check that the power door lock system operates normally. Refer to BL-16, "POWER DOOR LOCK
SYSTEM" .
Check that the automatic back door system operates normally. Refer to BL-101, "AUTOMATIC BACK
DOOR SYSTEM" .
4. Perform pre-diagnosis inspection. Refer to BL-59, "
BCM Power Supply and Ground Circuit Check" .
5. Refer to trouble diagnosis chart by symptom, repair or replace any malfunctioning parts. Refer to BL-60,
"Trouble Diagnoses" .
6. Inspection End.
BCM Power Supply and Ground Circuit CheckEIS003EF
1. CHECK FUSES AND FUSIBLE LINK
Check the following BCM fuses and fusible link.
NOTE:
Refer to BL-44, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of problem before installing new fuse, refer to PG-4,
"POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM.
3. Check voltage between BCM connectors M18, M20 terminals
11, 38, 57, 70 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
Component Parts Terminal No. (SIGNAL) Ampere No. Location
BCM57 (BAT power supply) 15A 22 Fuse block (J/B)
70 (BAT power supply) 50AfFuse and fusible link box
11 (ACC power supply) 10A 4 Fuse block (J/B)
38 (IGN power supply) 10A 59 Fuse and relay box
ConnectorTerminals
(Wire color)
Signal nameIgnition
switchVo l ta g e
(+) (–)
M2070 (W/B)
GroundBattery power
supplyOFFBattery
voltage
57 (Y/R)Battery power
supplyOFFBattery
voltage
M1811 ( O )ACC power
supplyACCBattery
voltage
38 (W/L)IGN power
supplyONBattery
voltage
WIIA0600E

Page 825 of 3371

BL-60
REMOTE KEYLESS ENTRY SYSTEM
Revision: August 20072004 QX56
3. CHECK GROUND CIRCUIT
Check continuity between BCM connector M20 terminal 67 and
ground.
OK or NG
OK >> Power supply and ground circuit is OK.
NG >> Repair or replace harness.
Trouble DiagnosesEIS002S0
SYMPTOM CHART
NOTE:
Always check the "Trouble Diagnosis Procedure" before troubleshooting. Refer to BL-59, "Trouble Diag-
nosis Procedure" .
Always check keyfob battery before replacing keyfob. Refer to BL-65, "Keyfob Battery and Function
Check" .
The panic alarm operation and power back door opener operation of remote keyless entry system do not
activate with the ignition key inserted in the ignition key cylinder.
Use Remote Keyless Entry Tester J-43241 (follow instructions on tester) to check operation of keyfob
before replacing keyfob.
ConnectorTe r m i n a l s
(Wire color)
Continuity
(+) (-)
M20 67 (B) Ground Yes
LIIA1040E
Symptom Diagnoses/service procedureReference
page
All functions of remote keyless entry system do not
operate.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Check BCM and keyless receiver.BL-66
The new ID of keyfob cannot be entered.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-652. Key switch and key lock solenoid (insert) checkBL-62
3. Door switch checkBL-63
4. ACC power checkBL-68
5. Replace BCM.BCS-19
Door lock or unlock does not function.
(If the power door lock system does not operate
manually, check power door lock system. Refer to
BL-16, "
POWER DOOR LOCK SYSTEM" )1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Replace BCM.BCS-19
Hazard and horn reminder does not activate prop-
erly when pressing lock or unlock button of keyfob.1. Check hazard and horn reminder mode with CONSULT-II
NOTE:
Hazard and horn reminder mode can be changed.
First check the hazard and horn reminder mode setting.BL-57
2. Door switch checkBL-63
3. Replace BCM.BCS-19

Page 826 of 3371

REMOTE KEYLESS ENTRY SYSTEM
BL-61
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Hazard reminder does not activate properly when
pressing lock or unlock button of keyfob.
(Horn reminder OK)1. Check hazard reminder mode with CONSULT-II
NOTE:
Hazard reminder mode can be changed.
First check the hazard reminder mode setting.BL-57
2. Check hazard function with hazard switch —
3. Replace BCM.BCS-19
Horn reminder does not activate properly when
pressing lock or unlock button of keyfob.
(Hazard reminder OK)1. Check horn reminder mode with CONSULT-II
NOTE:
Horn reminder mode can be changed.
First check the horn reminder mode setting.BL-57
2. Check horn function with horn switch —
3. IPDM E/R operation checkBL-68
4. Replace BCM.BCS-19
Back door open/close operation is not carried out
with keyfob operation.
(The automatic back door system is normal.)1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)BL-652. Key switch (insert) checkBL-62
3. Check that glass hatch is closed —
4. Remote keyless entry receiver systemBL-68
5. Replace BCM.BCS-19
Room lamp, ignition keyhole illumination and step
lamp operation do not activate properly.1. Room lamp operation checkBL-70
2. Ignition kehole illumination operation checkBL-70
3.Step lamp operation checkLT- 1 3 0
4. Door switch checkBL-63
5. Replace BCM.BCS-19
Panic alarm (horn and headlamp) does not activate
when panic alarm button is continuously pressed.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Key switch and key lock solenoid (insert) checkBL-62
3. Replace BCM.BCS-19
Auto door lock operation does not activate properly.
(All other remote keyless entry functions OK.)1. Check auto door lock operation mode with CONSULT-II
NOTE:
Auto door lock operation mode can be changed.
First check the auto door lock operation mode setting.BL-57
2. Replace BCM.BCS-19
Keyless power window down (open) operation does
not activate properly.
(All other remote keyless entry functions OK.)1. Check power window down operation mode with CONSULT-II
NOTE:
Power window down operation mode can be changed.
First check the power window down operation mode setting.BL-57
2. Check power window function with switch —
3. Replace BCM.BCS-19
Symptom Diagnoses/service procedureReference
page

Page 827 of 3371

BL-62
REMOTE KEYLESS ENTRY SYSTEM
Revision: August 20072004 QX56
Key Switch (Insert) CheckEIS002S1
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check key switch "KEY ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-27, "
DATA MONI-
TOR" .
When key is inserted to ignition key cylinder:
When key is removed from ignition key cylinder:
Without CONSULT-II
Check voltage between BCM connector M18 terminal 37 and
ground.
OK or NG
OK >> Key switch (insert) circuit is OK.
NG >> GO TO 2.
2. CHECK KEY SWITCH (INSERT)
1. Turn ignition switch OFF.
2. Disconnect key switch and key lock solenoid.
3. Check continuity between key switch terminals 3, 4.
OK or NG
OK >> Repair or replace harness.
NG >> Replace key switch.KEY ON SW : ON
KEY ON SW : OFF
LIIA0169E
ConnectorTerminal
(Wire color)
Condition Voltage (V)
( + ) ( – )
M18 37 (B/R) GroundKey is inserted. Battery voltage
Key is removed. 0
LIIA0567E
Terminals Condition Continuity
3 – 4Key is inserted. Yes
Key is removed. No
LIIA1044E

Page 831 of 3371

BL-66
REMOTE KEYLESS ENTRY SYSTEM
Revision: August 20072004 QX56
2. CHECK KEYFOB FUNCTION
With CONSULT-II
Check keyfob function in “DATA MONITOR” mode with CONSULT-II.
When pushing each button of keyfob, the corresponding monitor item should
be turned as follows.
Without CONSULT-II
Check keyfob function using Remote Keyless Entry Tester J-43241.
OK or NG
OK >> WITH CONSULT-II: Keyfob, remote keyless entry receiver and wiring harness between BCM and
remote keyless entry receiver are OK. Replace BCM. Refer to BCS-19, "
Removal and Installation
of BCM" .
OK >> WITHOUT CONSULT-II: Keyfob is OK. Further inspection is necessary. Refer to BL-60, "
Trouble
Diagnoses" .
NG >> WITH CONSULT-II: Further inspection is necessary. Refer to BL-60, "
Trouble Diagnoses" .
NG >> WITHOUT CONSULT-II: Replace keyfob. Refer to BL-71, "
ID Code Entry Procedure" .
Remote Keyless Entry Receiver System CheckEIS005X1
1. REMOTE KEYLESS ENTRY RECEIVER SIGNAL
Check signal voltage waveform between BCM connector M18 termi-
nal 20 and ground using an oscilloscope.
OK or NG
OK >> Remote keyless entry receiver signal power supply, ground and signal circuits are OK. Replace
BCM. Refer to BCS-19, "
Removal and Installation of BCM" .
NG >> GO TO 2.Condition Monitor item
Pushing LOCK KEYLESS LOCK : ON
Pushing UNLOCK KEYLESS UNLOCK : ON
Keep pushing UNLOCKRKE KEEP UNLK
turns to ON 3 seconds
after UNLOCK button
is pushed.
Pushing PANIC KEYLESS PANIC : ON
Pushing LOCK and UNLOCK
at the same timeRKE LCK-UNLCK : ON
Pushing Power Back Door KEYLESS PBD : ON
LIIA1487E
Condition:
Keyfob buttons released : Refer to BL-53, "
Te r m i -
nals and Reference Value
for BCM" .
Keyfob buttons pressed : Refer to BL-53, "
Te r m i -
nals and Reference Value
for BCM" .LIIA1275E

Page 833 of 3371

BL-68
REMOTE KEYLESS ENTRY SYSTEM
Revision: August 20072004 QX56
ACC Power CheckEIS002S5
1. CHECK ACC POWER
With CONSULT-II
Check "ACC ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-27, "
DATA MONITOR" .
Without CONSULT-II
Check voltage between BCM connector M18 terminal 11 and
ground.
OK or NG
OK >> ACC power circuit is OK.
NG >> Check the following:
10A fuse [No. 4, located in fuse block (J/B)]
Harness for open or short.
IPDM E/R Operation CheckEIS002S6
1. CHECK IPDM E/R INPUT VOLTAGE
Check voltage between IPDM E/R connector E122 terminal 45 and
ground.
OK or NG
OK >> Replace IPDM E/R.
NG >> GO TO 2.
Monitor Item Condition
ACC ON SWIgnition switch position ACC : ON
Ignition switch position OFF : OFF
PIIA3367E
ConnectorTe r m i n a l
(Wire color)
ConditionVoltage (V)
(Approx.)
( + ) ( – )
M18 11 (O) GroundACC Battery voltage
OFF 0
PIIA7002E
ConnectorTe r m i n a l
(Wire color)Voltage (V)
(Approx.)
( + ) ( – )
E122 45 (G/W) Ground Battery voltage
LIIA1053E

Page 841 of 3371

BL-76
VEHICLE SECURITY (THEFT WARNING) SYSTEM
Revision: August 20072004 QX56
System DescriptionEIS002SE
DESCRIPTION
Operation Flow

Setting the vehicle security system
Initial condition
Ignition switch is in OFF position.
Disarmed phase
When the vehicle is being driven or when doors or glass hatch is open, the vehicle security system is set
in the disarmed phase on the assumption that the owner is inside or near the vehicle.
Pre-armed phase and armed phase
There are three conditions to enable the vehicle security system to turn into the "pre-armed" phase and
transition into armed phase. The initial requirements are that hood, glass hatch and all doors must be
closed (ignition key removed) for the transition to take place. Those three conditions are:
1. Locking vehicle with either front power door lock switch before exiting vehicle and closing all doors.
2. Using keyfob to lock already closed doors after leaving the vehicle.
3. Using driver key cylinder switch to lock already closed doors after leaving the vehicle.
Upon any of the above three steps taking place, the security indicator lamp illuminates for 30 seconds,
then the system automatically shifts into the "armed" phase.
Canceling the set vehicle security system
When one of the following operations is performed, the armed phase is canceled.
1. Unlock the doors with the key or the keyfob.
2. Open the power back door with the keyfob. When the power back door is closed after opening the power
back door with the keyfob, the system returns to the armed phase.
Activating the alarm operation of the vehicle security system
Make sure the system is in the armed phase.
When one of the following operations is performed, the system sounds the horns and flashes the headlamps
for about 50 seconds.
1. Engine hood, glass hatch or any door is opened before unlocking door with key or keyfob.
2. Door is unlocked without using key or keyfob.
3. Power back door is opened without using the keyfob.
POWER SUPPLY AND GROUND CIRCUIT
Power is supplied at all times
through 10A fuse [No.19, located in the fuse block (J/B)]
PIIA1367E

Page:   < prev 1-10 ... 111-120 121-130 131-140 141-150 151-160 161-170 171-180 181-190 191-200 ... 510 next >