DTC U1000, U1001 CAN COMMUNICATION LINE
EC-135
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
DTC U1000, U1001 CAN COMMUNICATION LINEPFP:23710
DescriptionUBS00H0I
CAN (Controller Area Network) is a serial communication line for real time application. It is an on-vehicle mul-
tiplex communication line with high data communication speed and excellent error detection ability. Many elec-
tronic control units are equipped onto a vehicle, and each control unit shares information and links with other
control units during operation (not independent). In CAN communication, control units are connected with 2
communication lines (CAN H line, CAN L line) allowing a high rate of information transmission with less wiring.
Each control unit transmits/receives data but selectively reads required data only.
On Board Diagnosis LogicUBS00H0J
*1: This self-diagnosis has the one trip detection logic.
*2: The MIL will not light up for this diagnosis.
DTC Confirmation ProcedureUBS00H0K
1. Turn ignition switch ON and wait at least 3 seconds.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. If 1st trip DTC is detected, go to EC-137, "
Diagnostic Procedure" .
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
U1000*
1
1000*1
CAN communication line
ECM cannot communicate to other control
units.
ECM cannot communicate for more than the
specified time.
Harness or connectors
(CAN communication line is open or
shorted) U1001*
2
1001*2

Page 1330 of 3371

DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-139
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
DTC Confirmation ProcedureUBS00H0Q
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 10.5V and 16V at
idle.
WITH CONSULT-II
1. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-II.
2. Start engine and warm it up to the normal operating tempera-
ture.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start the engine and keep the engine speed between 3,500 rpm
and 4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
6. If 1st trip DTC is detected, go to EC-143, "
Diagnostic Procedure"
.
WITH GST
Follow the procedure “WITH CONSULT-II” above.
SEF 1 74 Y

Page 1332 of 3371

DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-141
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
6GRHeated oxygen sensor 2
heater (bank 1)[Engine is running]
Engine speed is below 3,600 rpm after the
following conditions are met.
–Engine: after warming up
–Keeping the engine speed between 3,500
and 4,000 rpm for 1 minute and at idle for 1
minute under no load.0 - 1.0V
[Ignition switch: ON]
Engine stopped
[Engine is running]
Engine speed is above 3,600 rpm.BATTERY VOLTAGE
(11 - 14V)

Page 1334 of 3371

DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-143
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureUBS00H0S
1. CHECK HO2S2 POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect heated oxygen sensor 2 harness connector.
3. Turn ignition switch ON.
4. Check voltage between HO2S2 terminal 3 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
25 O/GHeated oxygen sensor 2
heater (bank 2)[Engine is running]
Engine speed is below 3,600 rpm after the
following conditions are met.
–Engine: after warming up
–Keeping the engine speed between 3,500
and 4,000 rpm for 1 minute and at idle for 1
minute under no load.0 - 1.0V
[Ignition switch: ON]
Engine stopped
[Engine is running]
Engine speed is above 3,600 rpm.BATTERY VOLTAGE
(11 - 14V)
BBIA0435E
Voltage: Battery voltage
PBIB0 112 E

Page 1335 of 3371

EC-144Revision: August 2007
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
2004 QX56
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E5, F14
IPDM E/R connector E119
10A fuse
Harness for open or short between heated oxygen sensor 2 and fuse
>> Repair harness or connectors.
3. CHECK HO2S2 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK HEATED OXYGEN SENSOR 2 HEATER
Refer to EC-145, "
Component Inspection" .
OK or NG
OK >> GO TO 5.
NG >> Replace malfunctioning heated oxygen sensor 2.
5. CHECK INTERMITTENT INCIDENT
Refer to EC-127, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
DTCTe r m i n a l s
Bank
ECM Sensor
P0037, P0038 6 2 1
P0057, P0058 25 2 2
Continuity should exist.

Page 1338 of 3371

DTC P0101 MAF SENSOR
EC-147
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
DTC Confirmation ProcedureUBS00H0Y
Perform PROCEDURE FOR MALFUNCTION A first.
If the DTC cannot be confirmed, perform PROCEDURE FOR MALFUNCTION B.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
PROCEDURE FOR MALFUNCTION A
NOTE:
If engine will not start or stops soon, wait at least 10 seconds with engine stopped (Ignition switch ON) instead
of running engine at idle speed.
With CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and warm it up to normal operating temperature.
4. Run engine for at least 10 seconds at idle speed.
5. If DTC is detected, go to EC-150, "
Diagnostic Procedure" .
With GST
Follow the procedure “With CONSULT-II” above.
PROCEDURE FOR MALFUNCTION B
CAUTION:
Always drive vehicle at a safe speed.
With CONSULT-II
1. Turn ignition switch ON.
2. Start engine and warm it up to normal operating temperature.
If engine cannot be started, go to EC-150, "
Diagnostic Procedure" .
3. Select “DATA MONITOR” mode with CONSULT-II.
4. Check the voltage of “MAS A/F SE-B1” with “DATA MONITOR”.
5. Increases engine speed to about 4,000 rpm.
6. Monitor the linear voltage rise in response to engine speed
increases.
If NG, go to EC-150, "
Diagnostic Procedure" .
If OK, go to following step.
SEF 1 74 Y
SEF 2 43 Y

Page 1341 of 3371

EC-150Revision: August 2007
DTC P0101 MAF SENSOR
2004 QX56
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureUBS00H11
1. INSPECTION START
Which malfunction (A or B) is duplicated?
A or B
A >> GO TO 3.
B >> GO TO 2.
2. CHECK INTAKE SYSTEM
Check the following for connection.
Air duct
Vacuum hoses
Intake air passage between air duct to intake manifold
OK or NG
OK >> GO TO 3.
NG >> Reconnect the parts.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
51 W Mass air flow sensor[Engine is running]
Warm-up condition
Idle speed1.1 - 1.4V
[Engine is running]
Warm-up condition
Engine speed is 2,500 rpm.1.7 - 2.0V
67 B Sensor ground[Engine is running]
Warm-up condition
Idle speedApproximately 0V
111 W /BECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFFBATTERY VOLTAGE
(11 - 14V)
11 9
120BR
BRPower supply for ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)

Page 1342 of 3371

DTC P0101 MAF SENSOR
EC-151
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
3. RETIGHTEN GROUND SCREWS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
Refer to EC-133, "
Ground Inspection" .
OK or NG
OK >> GO TO 4.
NG >> Repair or replace ground connections.
4. CHECK MAF SENSOR POWER SUPPLY CIRCUIT
1. Disconnect mass air flow (MAF) sensor harness connector.
2. Turn ignition switch ON.
3. Check voltage between MAF sensor terminal 2 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
5. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E2, F32
Harness for open or short between IPDM E/R and mass air flow sensor
Harness for open or short between mass air flow sensor and ECM
>> Repair harness or connectors.
BBIA0354E
BBIA0368E
Voltage: Battery voltage
PBIB11 68 E

Page 1343 of 3371

EC-152Revision: August 2007
DTC P0101 MAF SENSOR
2004 QX56
6. CHECK MAF SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between MAF sensor terminal 3 and ECM terminal 67.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
7. CHECK MAF SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between MAF sensor terminal 4 and ECM terminal 51.
Refer to Wiring Diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 8.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
8. CHECK MASS AIR FLOW SENSOR
Refer to EC-153, "
Component Inspection" .
OK or NG
OK >> GO TO 9.
NG >> Replace mass air flow sensor.
9. CHECK INTERMITTENT INCIDENT
Refer to EC-127, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END Continuity should exist.
Continuity should exist.

Page 1344 of 3371

DTC P0101 MAF SENSOR
EC-153
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: August 20072004 QX56
Component InspectionUBS00H12
MASS AIR FLOW SENSOR
1. Reconnect all harness connectors disconnected.
2. Start engine and warm it up to normal operating temperature.
3. Check voltage between ECM terminal 51 (Mass air flow sensor
signal) and ground.
*: Check for linear voltage rise in response to engine being increased to about
4,000 rpm.
4. If the voltage is out of specification, proceed the following.
Turn ignition switch OFF.
Disconnect mass air flow sensor harness connector and reconnect it again.
Perform steps 2 and 3 again.
5. If NG, remove mass air flow sensor from air duct. Check hot wire for damage or dust.
6. If NG, clean or replace mass air flow sensor.
Removal and InstallationUBS00H13
MASS AIR FLOW SENSOR
Refer to EM-14, "AIR CLEANER AND AIR DUCT" .
Condition Voltage V
Ignition switch ON (Engine stopped.) Approx. 0.4
Idle (Engine is warmed-up to normal
operating temperature.)1.1 - 1.4
2,500 rpm (Engine is warmed-up to
normal operating temperature.)1.7 - 2.0
Idle to about 4,000 rpm* 1.1 - 1.4 to Approx. 4.0
PBIB11 06 E