ignition INFINITI QX56 2004 Factory Service Manual

Page 2551 of 3371

LT-120
PARKING, LICENSE PLATE AND TAIL LAMPS
Revision: August 20072004 QX56
6. CHECK GROUND
1. Check continuity between front combination lamp harness con-
nector and ground.
2. Check continuity between license lamps plate harness connec-
tor and ground.
3. Check continuity between rear combination lamp harness con-
nector and ground.
OK or NG
OK >> Check bulbs.
NG >> Repair harness or connector.
Parking, License Plate and Tail Lamps Do Not Turn OFF (After Approx. 10 Min-
utes)
EKS007CO
1. CHECK IPDM E/R
1. Turn ignition switch ON. Turn the combination switch (lighting switch) to the OFF position. Turn ignition
switch OFF.
2. Verify that the parking, license plate, and tail lamps turn on and off after approximately 10 minutes.
OK or NG
OK >> Ignition relay malfunction. Refer to PG-18, "Function of Detecting Ignition Relay Malfunction" .
NG >> Inspection End.
Front combination lamp
Continuity
ConnectorTe r m i n a l
(wire color)
RH E107
4 (B) Ground Yes
LH E11
WKIA1904E
License plate lamps
Continuity
ConnectorTerminal
(wire color)
D703 – (B) Ground Yes
WKIA1080E
Rear combination lamp
Continuity
ConnectorTe r m i n a l
(wire color)
RH B130
1 (B) Ground Yes
LH B70
WKIA1905E

Page 2554 of 3371

TRAILER TOW
LT-123
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: August 20072004 QX56
TRAILER TOWPFP:93020
Component Parts and Harness Connector LocationEKS007CT
System DescriptionEKS007CU
Power is supplied at all times
through 50A fusible link (letter f , located in the fuse and fusible link box)
to BCM (body control module) terminal 70, and
through 10A fuse [No. 32, located in the IPDM E/R (intelligent power distribution module engine room)]
through IPDM E/R terminal 61
to trailer tow relay 1 terminal 3, and
through 20A fuse (No. 53, located in the IPDM E/R)
to CPU of the IPDM E/R, and
through 30A fusible link (letter j , located in the fuse and fusible link box)
to trailer tow relay 2 terminals 3 and 6, and
through 40A fusible link (letter k , located in the fuse and fusible link box)
to electric brake (pre-wiring) terminal 5.
With the ignition switch in the ON or START position, power is supplied
WKIA3398E

Page 2555 of 3371

LT-124
TRAILER TOW
Revision: August 20072004 QX56
through 10A fuse (No. 59, located in the fuse and relay box)
to BCM terminal 38, and
through 10A fuse (No. 51, located in the IPDM E/R)
to trailer tow relay 2 terminal 1.
Ground is supplied
to BCM terminal 67 and
to electric brake (pre-wiring) terminal 1
through grounds M57, M61 and M79, and
to IPDM E/R terminals 38 and 59
to trailer tow relay 1 terminal 2
to trailer tow relay 2 terminal 2 and
to trailer connector terminal 2
through grounds E9, E15 and E24.
TRAILER TAIL LAMP OPERATION
The trailer tail lamps are controlled by the trailer tow relay 1.
With the lighting switch in the parking and tail lamp ON (1ST) position, AUTO position (and the auto light sys-
tem is activated) or headlamp ON (2ND) position, power is supplied
through the tail lamp relay, located in the IPDM E/R
through 10A fuse (No. 36, located in the IPDM E/R)
through IPDM E/R terminal 49
to trailer tow relay 1 terminal 1.
When energized, trailer tow relay 1 supplies tail lamp power to trailer connector terminal 6.
TRAILER BRAKE, TURN SIGNAL AND HAZARD LAMP OPERATION
The trailer brake, turn signal and hazard lamps are all controlled by the BCM. When the brake pedal is
depressed, the BCM receives stop lamp switch signal through CAN communication. If the brake pedal is
depressed or either turn signal or the hazard lamps are turned on, the BCM supplies voltage to the trailer
lamps to make them flash or turn on.
Left trailer brake, turn signal and hazard lamp output is supplied
through BCM terminal 52
to trailer connector terminal 1.
Right trailer brake, turn signal and hazard lamp output is supplied
through BCM terminal 51
to trailer connector terminal 4.
TRAILER BRAKE OPERATION
The trailer brake is controlled by the electric brake. The electric brake receives stop lamp switch signal at elec-
tric brake (pre-wiring) terminal 2 when the brake pedal is depressed.
When the brake pedal is depressed, power is supplied by the electric brake
through electric brake (pre-wiring) terminal 3
to trailer connector terminal 3.
TRAILER POWER SUPPLY OPERATION
The trailer power supply is controlled by the trailer tow relay 2.
When the ignition switch is in the ON or START position, power is supplied
through 10A fuse (No. 51, located in the IPDM E/R)
to IPDM E/R terminal 16
to trailer tow relay 2 terminal 1.
When energized, the trailer tow relay 2 supplies power
through trailer tow relay 2 terminals 5 and 7
to trailer connector terminal 5.

Page 2561 of 3371

LT-130
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
System DescriptionEKS007CY
When room lamp and personal lamp switch is in DOOR position, room lamp and personal lamp ON/OFF is
controlled by timer according to signals from switches including key switch and key lock solenoid, front door
switch LH, unlock signal from keyfob, door lock and unlock switch, front door lock assembly LH (key cylinder
switch), ignition switch, and glass hatch ajar switch.
When room lamp and personal lamp turns ON, there is a gradual brightening over 1 second. When room lamp
and personal lamp turns OFF, there is a gradual dimming over 1 second.
The room lamp and personal lamp timer is controlled by the BCM (body control module).
Room lamp and personal lamp timer control settings can be changed with CONSULT-II.
Ignition keyhole illumination turns ON when front door LH is opened (door switch ON) or key is removed from
key cylinder. Illumination turns OFF when front door LH is closed (door switch OFF).
Step and foot lamp turns ON when front or rear doors are opened (door switch ON). Lamp turns OFF when
front and rear doors are closed (all door switches OFF).
POWER SUPPLY AND GROUND
Power is supplied at all times
through 10A fuse [No. 19, located in the fuse block (J/B)]
to key switch and key lock solenoid terminal 3, and
through 15A fuse [No. 22, located in the fuse block (J/B)]
to BCM terminal 57, and
through 50A fusible link (letter f , located in the fuse and fusible link box)
to BCM terminal 70.
When the key is inserted in key switch and key lock solenoid, power is supplied
through the key switch and key lock solenoid terminal 4
to BCM terminal 37.
With the ignition switch in the ON or START position, power is supplied
through 10A fuse (No. 59, located in the fuse and relay box)
to BCM terminal 38.
Ground is supplied
to BCM terminal 67
through grounds M57, M61 and M79.
When the front door LH is opened, ground is supplied
to BCM terminal 47
through case ground of front door switch LH.
When the front door RH is opened, ground is supplied
to BCM terminal 12
through case ground of front door switch RH.
When the rear door LH is opened, ground is supplied
to BCM terminal 48
through case ground of rear door switch LH.
When the rear door RH is opened, ground is supplied
to BCM terminal 13
through case ground of rear door switch RH.
When the liftgate is opened, ground is supplied
to BCM terminal 43
through back door latch (door ajar switch) terminal 7
through back door latch (door ajar switch) terminal 8
through grounds B7 and B19.
When the glass hatch is opened, ground is supplied
to BCM terminal 42
through case ground of glass hatch ajar switch.

Page 2562 of 3371

INTERIOR ROOM LAMP
LT-131
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: August 20072004 QX56
When the front door LH or RH is unlocked by the door lock and unlock switch, BCM receives serial data
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14 or power window and door lock/
unlock switch RH terminal 16
through main power window and door lock/unlock switch terminal 17 or power window and door lock/
unlock switch RH terminal 11
through grounds M57, M61 and M79.
When the front door LH is unlocked by the key, the BCM receives serial data
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14
through main power window and door lock/unlock switch terminal 6
through front door lock assembly LH (key cylinder switch) terminal 6
through front door lock assembly LH (key cylinder switch) terminal 5
through grounds M57, M61 and M79.
When a signal, or combination of signals is received by BCM, ground is supplied
to door mirror LH and RH terminal 13
to front room/map lamp assembly terminal 1
through front room/map lamp assembly terminal 2
to personal lamps terminal 1
through BCM terminal 63, and
to cargo lamp terminal 1
through BCM terminal 49.
With power and ground supplied, the lamps illuminate.
SWITCH OPERATION
When any door switch is ON (door is opened), ground is supplied
to front and rear step lamps LH and RH and foot lamp LH and RH terminal –
through BCM terminal 62.
And power is supplied
through BCM terminal 56
to front and rear step lamps LH and RH terminal +
to ignition keyhole illumination terminal +
to door mirror LH and RH terminal 12
to front room/map lamp assembly terminal 6
to vanity lamps terminal 1
to personal lamps terminal 3
to cargo lamp terminal 2, and
to foot lamp LH and RH terminal +.
When map lamp switch is ON, ground is supplied
to front room/map lamp assembly terminal 5
through grounds M57, M61 and M79.
When vanity lamp (LH and RH) is ON, ground is supplied
to vanity lamp (LH and RH) terminal 2
through grounds M57, M61 and M79.
When cargo lamp is ON, ground is supplied through cargo lamp case ground.
ROOM LAMP TIMER OPERATION
When lamp switch is in DOOR position, and when all conditions below are met, BCM performs timer control
(maximum 30 seconds) for interior room lamp and map lamp ON/OFF.
Power is supplied
through 10A fuse [No. 19, located in the fuse block (J/B)]

Page 2563 of 3371

LT-132
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
to key switch and key lock solenoid terminal 3.
Key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM terminal 37.
Serial data is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
At the time that front door LH is opened, BCM detects that front door LH is unlocked. It determines that interior
room lamp and map lamp timer operation conditions are met, and turns the interior room lamps ON for 30 sec-
onds.
Key is in ignition key cylinder (key switch ON), power is supplied
through key switch and key lock solenoid terminal 4
to BCM terminal 37.
When key is removed from key switch and key lock solenoid (key switch OFF), power supply to BCM terminal
37 is terminated. BCM detects that key has been removed, determines that interior room lamp and map lamp
timer conditions are met, and turns the interior room lamps ON for 30 seconds.
When front door LH opens → closes, and the key is not inserted in the key switch and key lock solenoid (key
switch OFF), BCM terminal 47 changes between 0V (door open) → 12V (door closed). The BCM determines
that conditions for interior room lamp operation are met and turns the interior room lamp ON for 30 seconds.
Timer control is canceled under the following conditions.
Front door LH is locked [when locked by keyfob, main power window and door lock/unlock switch, or front
door lock assembly LH (key cylinder switch)]
Front door LH is opened (front door switch LH turns ON)
Ignition switch ON.
INTERIOR LAMP BATTERY SAVER CONTROL
If interior lamp is left “ON”, it will not be turned off even when door is closed.
BCM turns off interior lamp automatically to save battery 30 minutes after ignition switch is turned off.
BCM controls interior lamps listed below:
Vanity lamp
Room/map lamp
Cargo lamp
Personal lamp
Step lamps
Puddle lamps
Foot lamps
Ignition keyhole illumination
After lamps turn OFF by the battery saver system, the lamps illuminate again when
signal received from keyfob, or main power window and door lock/unlock switch or front door lock assem-
bly LH (key cylinder switch) is locked or unlocked
door is opened or closed
key is removed from ignition key cylinder (key switch OFF) or inserted in ignition key cylinder (key switch
ON).
Interior lamp battery saver control period can be changed by the function setting of CONSULT-II.

Page 2573 of 3371

LT-142
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
Terminals and Reference Values for BCMEKS007D1
How to Proceed With Trouble DiagnosisEKS007D2
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT-130, "
System Description" .
3. Carry out the Preliminary Check. Refer to LT- 1 4 3 , "
Preliminary Check" .
4. Check symptom and repair or replace the cause of malfunction.
5. Does the interior room lamp operate normally? If YES: GO TO 6. If NO: GO TO 4.
6. Inspection End.
Te r m i n a l
No.Wire
colorSignal nameMeasuring condition
Reference value
(Approx.) Ignition
switchOperation or condition
12 R/LFront door switch RH
signalOFFFront door switch
RHON (open) 0V
OFF (closed) Battery voltage
13 GRRear door switch RH
signalOFFRear door switch
RHON (open) 0V
OFF (closed) Battery voltage
22 W/VPower window switch
serial link——
37 B/RKey-in switch detec-
tion signalOFFVehicle key is removed. 0V
Vehicle key is inserted. Battery voltage
38 W/L Ignition power supply ON — Battery voltage
39 W CAN-H — — —
40 R CAN-L — — —
42 GRGlass hatch ajar
switch signalOFFGlass hatch ajar
switchON (open) 0V
OFF (closed) Battery voltage
43 R/BBack door latch (door
ajar switch) signalOFFBack door latch
(door ajar switch)ON (open) 0V
OFF (closed) Battery voltage
47 SBFront door switch LH
signalOFFFront door switch
LHON (open) 0V
OFF (closed) Battery voltage
48 R/YRear door switch LH
signalOFFRear door switch
LHON (open) 0V
OFF (closed) Battery voltage
56 R/GBattery saver output
signalOFF30 minutes after ignition switch is turned
to OFF0V
ON — Battery voltage
57 Y/R Battery power supply OFF — Battery voltage
62 R/W Step lamp signal OFFAny door is open (ON) 0V
All doors are closed (OFF) Battery voltage
63 LInterior room/map
lamp signalOFFEach interior lamp
switch in DOOR
positionAny door
switchON
(open)0V
OFF
(closed)Battery voltage
67 B Ground ON — 0V
70 W/B Battery power supply OFF — Battery voltage
PIIA2344J

Page 2574 of 3371

INTERIOR ROOM LAMP
LT-143
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: August 20072004 QX56
Preliminary CheckEKS007D3
INSPECTION FOR POWER SUPPLY AND GROUND CIRCUIT
1. CHECK FUSES OR FUSIBLE LINK
Check for blown BCM fuses or fusible link.
Refer to LT-135, "
Wiring Diagram — INT/L —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of blown fuse before installing new fuse. Refer to PG-
4, "POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Disconnect BCM connectors.
2. Check voltage between BCM connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness for open between BCM and fuse or fusible link.
3. CHECK GROUND CIRCUIT
Check continuity between BCM and ground.
OK or NG
OK >> Inspection End.
NG >> Check harness ground circuit.
Unit Power source Fuse or fusible link No.
BCMBatteryf
22
Ignition switch ON or START position 59
BCM
(–)Ignition switch position
(+)
OFF ON
ConnectorTerminal
(wire color)
M2057 (Y/R)
GroundBattery voltage Battery voltage
70 (W/B) Battery voltage Battery voltage
M18 38 (W/L) 0V Battery voltage
WKIA1478E
BCM
Continuity
ConnectorTe r m i n a l
(wire color)
M20 67 (B) Ground Yes
LIIA0915E

Page 2575 of 3371

LT-144
INTERIOR ROOM LAMP
Revision: August 20072004 QX56
CONSULT-II Function (BCM)EKS007D4
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT-II OPERATION
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carries out CAN communication.
1. With the ignition switch OFF, connect CONSULT-II and CON-
SULT-II CONVERTER to the data link connector, then turn igni-
tion switch ON.
2. Touch “START (NISSAN BASED VHCL)”.
3. Touch “BCM” on “SELECT SYSTEM” screen.
If “BCM” is not indicated, go to GI-39, "
CONSULT-II Data Link
Connector (DLC) Circuit" .
BCM diagnostic
test itemDiagnostic mode Description
Inspection by partWORK SUPPORTSupports inspections and adjustments. Commands are transmitted to the BCM
for setting the status suitable for required operation, input/output signals are
received from the BCM and received data is displayed.
DATA MONITOR Displays BCM input/output data in real time.
ACTIVE TEST Operation of electrical loads can be checked by sending drive signal to them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTR The result of transmit/receive diagnosis of CAN communication can be read.
ECU PART NUMBER BCM part number can be read.
CONFIGURATION Performs BCM configuration read/write functions.
BBIA0369E
BCIA0029E
BCIA0030E

Page 2576 of 3371

INTERIOR ROOM LAMP
LT-145
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: August 20072004 QX56
4. Touch “INT LAMP” on “SELECT TEST ITEM” screen.
WORK SUPPORT
Operation Procedure
1. Touch “INT LAMP” on “SELECT TEST ITEM” screen.
2. Touch “WORK SUPPORT” on “SELECT DIAG MODE” screen.
3. Touch “SET I/L D-UNLCK INTCON” on “SELECT WORK ITEM” screen.
4. Touch “START”.
5. Touch “CHANGE SETT”.
6. The setting will be changed and “CUSTOMIZING COMPLETED” will be displayed.
7. Touch “END”.
Display Item List
Reference between “MODE” and “TIME” for “TURN ON/OFF”.
DATA MONITOR
Operation Procedure
1. Touch “INT LAMP” on “SELECT TEST ITEM” screen.
2. Touch “DATA MONITOR” on “SELECT DIAG MODE” screen.
3. Touch either “ALL SIGNALS” or “SELECTION FROM MENU” on “SELECT MONITOR ITEM” screen.
4. Touch “START”.
5. When “SELECTION FROM MENU” is selected, touch items to be monitored. When “ALL SIGNALS” is
selected, all the items will be monitored.
6. Touch “RECORD” while monitoring, then the status of the monitored item can be recorded. To stop
recording, touch “STOP”.
PKIA5226E
Item Description CONSULT-II
SET I/L D-UNLCK INTCONThe 30 seconds operating function of the interior room lamps and the
ignition keyhole illumination can be selected when front door LH is
released (unlocked). ON/OFF
ROOM LAMP ON TIME SETThe time in order to escalate illumination can be adjusted when the
interior room lamps and the ignition keyhole illumination is turned on.MODE 1 - 7
ROOM LAMP OFF TIME SETThe time in order to diminish illumination can be adjusted when the
interior room lamps and the ignition keyhole illumination is turned off.MODE 1 - 7
MODE12345 6 7
Time (sec.) 0.5 1 2 3 4 5 0
ALL SIGNALS Monitors all the signals.
SELECTION FROM MENU Selects and monitors the individual signal.

Page:   < prev 1-10 ... 861-870 871-880 881-890 891-900 901-910 911-920 921-930 931-940 941-950 ... 1120 next >