fuse box INFINITI QX56 2004 Factory Service Manual
Page 467 of 3371
ATC-62
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
1. CHECK POWER SUPPLY CIRCUITS FOR FRONT AIR CONTROL
1. Disconnect front air control connector M49.
2. Check voltage between front air control harness connector M49
terminals 14 (Y/G) and 22 (Y/R), and ground.
OK or NG
OK >> GO TO 2.
NG >> Check 10A fuses [No. 8 and 19, located in the fuse block (J/B)]. Refer to PG-76, "
FUSE BLOCK-
JUNCTION BOX(J/B)" .
If fuses are OK, check harness for open circuit. Repair or replace as necessary.
If fuses are NG, replace fuse and check harness for short circuit. Repair or replace as neces-
sary.
2. CHECK GROUND CIRCUIT FOR FRONT AIR CONTROL
1. Turn ignition switch OFF.
2. Check continuity between front air control harness connector
M49 terminal 1 (B) and ground.
OK or NG
OK >> Replace front air control. Refer to ATC-135, "FRONT
AIR CONTROL" .
NG >> Repair harness or connector.
Terminals Ignition switch position
(+)
(-) OFF ACC ON Front air
control
connectorTerminal No.
(Wire color)
M4914 (Y/G)
GroundApprox. 0V Approx. 0VBattery
voltage
22 (Y/R)Battery
voltageBattery
voltageBattery
voltage
WJIA0415E
1 - Ground : Continuity should exist.
WJIA0964E
Page 491 of 3371
ATC-86
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
1. CHECK FUSES
Check 20A fuses [No. 24 and 27 (located in the fuse and fusible link box)]. For fuse layout. Refer to PG-77,
"FUSE AND FUSIBLE LINK BOX" .
OK or NG
OK >> GO TO 2.
NG >> GO TO 10.
2. CHECK FRONT BLOWER MOTOR POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front blower motor connector M62.
3. Turn ignition switch ON.
4. Press the MODE switch to select any mode except OFF.
5. Set front fan switch to high.
6. Check voltage between front blower motor harness connector
M62 terminal 2 (W/L) and ground.
OK or NG
OK >> GO TO 12.
NG >> GO TO 3.
3. CHECK FRONT BLOWER MOTOR RELAY (SWITCH SIDE) POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front blower motor relay M107.
3. Check voltage between front blower motor relay harness con-
nector M107 terminals 5 (GR) and 7 (P), and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector.
4. CHECK FRONT BLOWER MOTOR RELAY
Refer to ATC-89, "
Front Blower Motor Relay" .
OK or NG
OK >> GO TO 5.
NG >> Replace front blower motor relay.
5. CHECK FRONT BLOWER MOTOR RELAY (SWITCH SIDE) CIRCUIT FOR OPEN
1. Turn ignition switch OFF.
2. Disconnect blower motor relay connector M107 and front blower
motor connector M62.
3. Check continuity between front blower motor relay harness con-
nector M107 terminals 3 (W/L) and 6 (W/L)
and front blower motor harness connector M62 terminal 2 (W/L).
OK or NG
OK >> GO TO 6.
NG >> Repair harness or connector.2 - Ground : Battery voltage should exist.
WJIA1331E
5, 7 - Ground : Battery voltage should exist.
WJIA0780E
3, 6 - 2 : Continuity should exist.
WJIA0781E
Page 499 of 3371
ATC-94
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
1. DIAGNOSTIC PROCEDURE
Blower motor rotates normally at each speed.
OK or NG
OK >> Inspection End.
NG >> 1. Does not rotate at any speed, GO TO 2.
2. Does not rotate at 1 - 3 speed, GO TO 13.
3. Does not rotate at 4 speed, GO TO 18.
2. CHECK FUSES
Check 15A fuses [Nos. 10 and 11, located in the fuse block (J/B)]. Refer to PG-76, "
FUSE BLOCK-JUNCTION
BOX(J/B)" .
OK or NG
OK >> GO TO 3.
NG >> GO TO 8.
3. CHECK REAR BLOWER MOTOR POWER SUPPLY
1. Turn ignition switch OFF.
2. Disconnect rear blower motor connector B134.
3. Select any rear blower speed except OFF.
4. Turn ignition switch ON.
5. Check voltage between rear blower motor harness connector
B134 terminal 2 (L/R) and ground.
OK or NG
OK >> GO TO 11.
NG >> GO TO 4.
4. CHECK REAR BLOWER MOTOR RELAY
Refer to ATC-99, "
Rear Blower Motor Relay" .
OK or NG
OK >> GO TO 5.
NG >> Replace rear blower motor relay.
5. CHECK REAR BLOWER MOTOR POWER FROM RELAY TO REAR BLOWER MOTOR
1. Turn ignition switch OFF.
2. Reconnect rear blower motor connector.
3. Disconnect rear blower motor relay J1.
4. Turn ignition switch ON.
5. Set rear fan switch (front) to any position except off (0), rear (R),
or 4 - speed.
6. Momentarily (no more than 4 seconds), connect a jumper wire
between rear blower motor relay connector J1 terminals 3 and 5.
OK or NG
OK >> GO TO 6.
NG >> GO TO 10.1 - Ground : Battery voltage should exist.
WJIA0596E
Rear blower motor should rotate.LJIA0100E
Page 500 of 3371
TROUBLE DIAGNOSIS
ATC-95
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
6. CHECK REAR BLOWER MOTOR RELAY (COIL SIDE) POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect fuse block (J/B) connector M39.
3. Turn ignition switch ON.
4. Set rear fan switch (front) to any position except off (0), rear (R),
or 4 - speed.
5. Check voltage between fuse block (J/B) harness connector M39
terminal 3Q (W/L) and ground.
OK or NG
OK >> GO TO 7.
NG >> GO TO 20.
7. CHECK REAR BLOWER MOTOR RELAY (COIL SIDE) GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect fuse block (J/B) connector M3.
3. Check continuity between fuse block (J/B) harness connector
M3 terminal 7N (B) and ground.
OK or NG
OK >> Replace fuse block (J/B).
NG >> Repair harness or connector.
8. REPLACE FUSE
Refer to PG-76, "
FUSE BLOCK-JUNCTION BOX(J/B)" .
Fuse should not open when rear blower motor is activated.
OK or NG
OK >> Inspection End.
NG >> GO TO 9.
9. CHECK REAR BLOWER MOTOR POWER SUPPLY CIRCUIT FOR SHORT
1. Turn ignition switch OFF.
2. Disconnect battery cables and rear blower motor connector
B134.
3. Check continuity between rear blower motor harness connector
B134 terminal 2 (L/R) and ground.
OK or NG
OK >> Check rear blower motor. Refer to ATC-100, "Rear
Blower Motor" .
NG >> Repair harness or connector.1 - Ground : Battery voltage should exist.
LJIA0101E
7N - Ground : Continuity should exist.
WJIA0597E
2 - Ground : Continuity should not exist.
WJIA0598E
Page 594 of 3371
AUDIO
AV-7
C
D
E
F
G
H
I
J
L
MA
B
AV
Revision: August 20072004 QX56
System DescriptionEKS007KA
Refer to Owner's Manual for audio system operating instructions.
Power is supplied at all times
through 15A fuse [No. 17, located in the fuse block (J/B)]
to subwoofer terminal 6
through 20A fuse [No. 31, located in the fuse and fusible link box]
to audio unit terminal 6
to BOSE speaker amp. terminal 1
to AV switch terminal 1 and
to display control unit terminal 1.
With the ignition switch in the ACC or ON position, power is supplied
through 10A fuse [No. 4, located in the fuse block (J/B)]
to audio unit terminal 10 and
to AV switch terminal 2 and
to display control unit terminal 10.
With the ignition switch in the ON or START position, power is supplied
through 10A fuse [No. 12, located in the fuse block (J/B)]
to display control unit terminal 12.
Ground is supplied through the case of the audio unit.
Ground is also supplied
to subwoofer terminal 5
through body grounds B7 and B19 and
to BOSE speaker amp. terminal 17
to AV switch terminal 5 and
to display unit terminal 1 and
to display control unit terminal 3
through body grounds M57, M61 and M79.
Then audio signals are supplied
through audio unit terminals 1, 2, 3, 4, 13, 14, 15 and 16
to BOSE speaker amp. terminals 23, 24, 25, 26, 27, 28, 29 and 30.
Audio signals are amplified by the BOSE speaker amp.
The amplified audio signals are supplied
through BOSE speaker amp. terminals 2, 3, 9,10,11,12, 13, 14, 15, 16, 18 and 19
to terminals + and - of front door speaker LH and RH and
to terminals + and - of front tweeter LH and RH and
to terminals + and - of center speaker and
to terminals + and - of rear door speaker LH and RH and
to terminals + and - of rear door tweeter LH and RH and
to terminals 1 and 2 of subwoofer.
When one of steering wheel audio control switches is pushed, the resistance in steering switch circuit changes
depending on which button is pushed.
REAR AUDIO REMOTE CONTROL UNIT
Power is supplied
from audio unit terminal 32
to rear audio remote control unit terminal 13.
Ground is supplied
to rear audio remote control unit terminal 15
through body grounds B117 and B132.
Audio signals are supplied
Page 595 of 3371
AV-8
AUDIO
Revision: August 20072004 QX56
through audio unit terminals 26, 27, 28 and 29
to terminals 1, 2, 3, and 4 of rear audio remote control unit.
SATELLITE RADIO TUNER (PRE-WIRING)
The satellite radio tuner pre-wiring allows connection of a satellite radio tuner.
Power is supplied at all times
through 20A fuse [No. 31, located in the fuse and fusible link box]
to satellite radio tuner pre-wiring terminal 32.
With the ignition switch in the ACC or ON position, power is supplied
through 10A fuse [No. 4, located in the fuse block (J/B)]
to satellite radio tuner pre-wiring terminal 36.
Ground is supplied through the case of the satellite radio tuner.
SPEED SENSITIVE VOLUME SYSTEM
Volume level of this system goes up and down automatically in proportion to the vehicle speed. The control
level can be selected by the customer. Refer to Owner's Manual for operating instructions.
Page 640 of 3371
DVD ENTERTAINMENT SYSTEM
AV-53
C
D
E
F
G
H
I
J
L
MA
B
AV
Revision: August 20072004 QX56
System DescriptionEKS007LB
Refer to Owner's Manual for DVD entertainment system operating instructions.
Power is supplied at all times
through 20A fuse (No. 31, located in the fuse and fusible link box)
to DVD player terminal 16.
With the ignition switch in the ACC or ON position, power is supplied
through 10A fuse [No. 4, located in the fuse block (J/B)]
to DVD player terminal 15.
Power is also supplied
from DVD player terminals 31 and 32
to video monitor terminals 11 and 12.
Ground is supplied
to DVD player terminal 22
through body grounds M57, M61 and M79.
Audio signals are supplied
through DVD player terminals 1, 2, 3 and 4
to audio unit terminals 34, 35, 36 and 37.
Video signals are supplied
through DVD player terminals 23, 24, 28 and 29
to video monitor terminals 5, 6, 7 and 8.
Page 782 of 3371
POWER DOOR LOCK SYSTEM
BL-17
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
System DescriptionEIS002R9
Power is supplied at all times
to BCM terminal 70
through 50A fusible link (letter f, located in the fuse and fusible link box) and
to BCM terminal 57
through 15A fuse [No. 22, located in the fuse block (J/B)] and
to key switch and key lock solenoid terminal 3
through 10A fuse [No. 19, located in the fuse block (J/B)].
With ignition key inserted, power is supplied
to BCM terminal 37
through key switch and key lock solenoid terminals 3 and 4
through 10A fuse [No. 19, located in fuse block (J/B)].
Ground is supplied to terminal 67 of BCM through body grounds M57, M61 and M79.
When the door is locked or unlocked with main power window and door lock/unlock switch, ground is supplied
to CPU of main power window and door lock/unlock switch
through main power window and door lock/unlock switch terminal 17
through grounds M57, M61 and M79.
Then main power window and door lock/unlock switch operation signal is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
When the door is locked or unlocked with power window and door lock/unlock switch RH, ground is supplied
to CPU of power window and door lock/unlock switch RH
through power window and door lock/unlock switch RH terminal 11
through grounds M57, M61 and M79.
Then power window and door lock/unlock switch RH operation signal is supplied
to BCM terminal 22
through power window and door lock/unlock switch RH terminal 16.
When the door is locked with front door lock assembly LH (key cylinder switch), ground is supplied
to main power window and door lock/unlock switch terminal 4
through front door lock assembly LH (key cylinder switch) terminals 1 and 5
through grounds M57, M61 and M79.
Then front door lock assembly LH (key cylinder switch) operation signal is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
When the door is unlocked with front door lock assembly LH (key cylinder switch), ground is supplied
to main power window and door lock/unlock switch terminal 6
through front door lock assembly LH (key cylinder switch) terminals 6 and 5
through grounds M57, M61 and M79.
Then front door lock assembly LH (key cylinder switch) operation signal is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
BCM is connected to main power window and door lock/unlock switch and power window and door lock/unlock
switch RH through a serial link.
When the front door switch LH is ON (door is open), ground is supplied
to BCM terminal 47
through front door switch LH terminal 2
through front door switch LH case ground.
When the front door switch RH is ON (door is open), ground is supplied
to BCM terminal 12
Page 794 of 3371
POWER DOOR LOCK SYSTEM
BL-29
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Trouble Diagnoses Symptom ChartEIS0 02 RF
BCM Power Supply and Ground Circuit CheckEIS002RG
1. CHECK FUSE AND FUSIBLE LINK
Check the following BCM fuse and fusible link.
NOTE:
Refer to BL-101, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of problem before installing new fuse, refer to PG-4,
"POWER SUPPLY ROUTING CIRCUIT" .
Symptom Repair order Refer to page
Key reminder door function does not operate
properly.1. Door switch checkBL-31
2. Key switch (insert) checkBL-33
3. Replace BCM.BCS-19
Power door lock does not operate with door lock
and unlock switch on main power window and
door lock/unlock switch or power window and
door lock/unlock switch RH.1. Door lock/unlock switch checkBL-34
Front door lock assembly LH (actuator) does not
operate.1. Front door lock assembly LH (Actuator) checkBL-37
Specific door lock actuator does not operate.1. Front door lock actuator RH checkBL-392. Rear door lock actuator RH/LH checkBL-40
Power door lock does not operate with front door
key cylinder LH operation.1. Front door lock assembly LH (key cylinder
switch) checkBL-42
2. Replace BCM.BCS-19
Power door lock does not operate.1. BCM power supply and ground circuit checkBL-292. Door lock/unlock switch checkBL-34
Back door opener does not operate.1. Back door power supply and ground circuit
inspectionBL-1172. Door switch checkBL-31
3. Power liftgate switch system inspectionBL-118
Glass hatch lock actuator does not operate.1. Glass hatch switch checkBL-362.Glass hatch lock actuator checkBL-41
3. Replace BCM.BCS-19
Component Parts Terminal No. (SIGNAL) Ampere No. Location
BCM 57 (BAT power supply) 15A 22 Fuse block (J/B)
BCM 70 (BAT power supply) 50AfFuse and fusible link box
Page 810 of 3371
REMOTE KEYLESS ENTRY SYSTEM
BL-45
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
System DescriptionEIS002RP
INPUTS
Power is supplied at all times
to BCM terminal 70
through 50A fusible link (letter f , located in the fuse and fusible link box).
to BCM terminal 57
through 15A fuse [No. 22, located in the fuse block (J/B)].
When the key is inserted in key switch and key lock solenoid, power is supplied
to BCM terminal 37
through key switch and key lock solenoid terminals 3 and 4
through 10A fuse [No. 19, located in the fuse block (J/B)].
When the ignition switch is in ACC or ON position, power is supplied
to BCM terminal 11
through 10A fuse [No. 4, located in the fuse block (J/B)].
When the ignition switch is in ON or START position, power is supplied
to BCM terminal 38
through 10A fuse (No. 59, located in the fuse and relay box).
When the front door switch LH is ON (door is OPEN), ground is supplied
to BCM terminal 47
through front door switch LH terminal 2
through front door switch LH case ground.
When the front door switch RH is ON (door is OPEN), ground is supplied
to BCM terminal 12
through front door switch RH terminal 2
through front door switch RH case ground.
When the rear door switch LH is ON (door is OPEN), ground is supplied
to BCM terminal 48
through rear door switch LH terminal 2
through rear door switch LH case ground.
When the rear door switch RH is ON (door is OPEN), ground is supplied
to BCM terminal 13
through rear door switch RH terminal 2
through rear door switch RH case ground.
When the back door latch (door ajar switch) is ON (door is OPEN), ground is supplied
to BCM terminal 43
through back door latch (door ajar switch) terminal 7,
through back door latch (door ajar switch) terminal 8,
through body grounds B7 and B19.
When the glass hatch ajar switch is ON (glass hatch is OPEN), ground is supplied
to BCM terminal 42
through glass hatch ajar switch
through glass hatch ajar switch case ground.
Keyfob signal is input into the BCM from the remote keyless entry receiver.
The remote keyless entry system controls operation of the:
power door lock
back door opener
interior lamp and step lamps
panic alarm
hazard and horn reminder