Powering Down the High Voltage System
The high voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to
Primary Procedure
(FRG–21)
.
• Remove the underhood fuse for the high voltage control system and disconnect the 12-volt battery. Refer to
Alternate Procedure 1 (Remove Fuses) (FRG–23).
• Remove the service plug and disconnect the 12-volt battery. Refer to
Alternate Procedure 2
(Remove Service Plug) (FRG–25)
.
Primary Procedure
NOTE: Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery is
disconnected, power controls will not operate.
1. If possible, check the READY
indicator status in the instrument cluster. If it is on, the high
voltage system is active.
2. Place the shift selector in the Park (P) position.
3. Push the ignition switch once to turn OFF the high voltage system. Verify that the READY indicator is off
and then continue to the next steps to open the hood for
12-volt battery negative cable access.
If the READY indicator does not turn off, refer to
Alternate Procedure 1 (Remove Fuses) (FRG–23).
4. If possible, keep the Infiniti Intelligent Key at least 5 meters (16 feet) away from the vehicle.
AAYIA0191ZZ
ACC
LOCK
(OFF)
ON
AAYIA0271ZZ
AAYIA0340ZZ
FRG–21

Page 26 of 42

4. If possible, keep the Infiniti Intelligent Key at least5 meters (16 feet) away from the vehicle (except to
open the liftgate as noted below) .
5. Open the liftgate using any of the following: a. liftgate switch on the lower LH side of theinstrument panel.
b. liftgate button on the Infiniti Intelligent Key [press for longer than one (1) second].
c. liftgate opener switch (located above license plate)*
AAYIA0340ZZ
AAYIA0276ZZ
AAYIA0340ZZ
A
AAYIA0266ZZ
FRG–26

Page 27 of 42

d. If the liftgate cannot be opened with theinstrument panel switch, liftgate opener switch,
or key fob due to a discharged battery, follow
these steps:
• Remove the cover (A) on the inside of the
liftgate.
• Move the lever (B) as illustrated to open liftgate.
* You must have the Infiniti Intelligent Key within approximately 1 meter (3 feet) range of
liftgate opener switch to use the liftgate opener switch function.
6. Open luggage board.
7. Open service plug access cover.A
B
AAYIA0316ZZ
A
AAYIA0267ZZ
AAYIA0268ZZ
FRG–27

Page 33 of 42

Vehicle Cut Sheet









1-800-662-6200 (US) or 1-800-361-4792 (Canada)
Hours of Operation: 8am-5pm (Monday-Friday)
Eastern, Central and Pacific Time Zones
High voltage component
or harness (Can be cut
only after the high voltage
system shut-down procedure has been completed.) Never cut high voltage
components/batteries identified as "NEVER CUT" for any reason.
Death or serious personal injury will result. Traction Motor
Traction Motor
Inverter
High voltage
harness
High voltage
battery 12-volt
battery
12-volt Battery
Key
DANGER
voltage component
Nissan North America, Inc. Version 2, June 2014 NEVER CUT-High Infiniti Emergency Contact
AAYIA0111GB
FRG–33