ISUZU TF SERIES 2004 Workshop Manual

Page 3081 of 4264

HEATER AND AIR CONDITIONING 1-71
Important Operation - Removal
2. Instrument Panel Driver Lower Cover
Refer to “INSTRUMENT PANEL” in CAB section.


RTW310SH000101

4. Control Cables
Disconnect control cables at each unit side.


5. Center Cluster
Refer to “INSTRUMENT PANEL” in CAB section.

Page 3082 of 4264

1-72 HEATER AND AIR CONDITIONING













Important Operation - Installation
9. Control Lever Assembly
Air source control cable
RHD
1) Slide the control lever to the left (“CIRC” position).
2) Connect the control cable at the "CIRC" position of the link
unit of blower assembly and fix it with the clip.
LHD
1) Slide the control lever to the right (“FRESH” position).
2) Connect the control cable at the "FRESH" position of the
link unit of blower assembly and fix it with the clip.

Temperature control cable
RHD
1) Turn the control knob to the right (“FULL HOT” position).
2) Connect the control cable at the “FULL HOT” position of the
mix lever of the heater unit and fix it with the clip.
LHD
1) Turn the control knob to the left (“FULL COLD” position).
2) Connect the control cable at the “FULL COLD”position o
f
the mix lever of the heater unit and fix it with the clip.

Air select control cable
RHD
1) Turn the control knob to the left (“VENT” position).
2) Connect the control cable at the “VENT” position of the
mode control link of the heater unit and fix it with the clip.
LHD
1) Turn the control knob to the right (“DEF” position).
2) Connect the control cable at the “DEF” position of the mode
control link of the heater unit and fix it with the clip.

4. Control Cables
Check control cable operation


Page 3083 of 4264

HEATER AND AIR CONDITIONING 1-73

RTW410MF000201

Page 3084 of 4264

1-74 HEATER AND AIR CONDITIONING
CONTROL PANEL ILLUMINATION BULB
REMOVAL AND INSTALLATION

This illustration is based on RHD model
RTW410MF000601

Removal Steps
 1. Control lever assembly
 2. Illumination bulb

Installation Steps
2. Illumination bulb
1. Control lever assembly

Page 3085 of 4264

HEATER AND AIR CONDITIONING 1-75
Important Operation - Removal
1. Control lever assembly
Refer to “CONTROL LEVER ASSEMBLY” in this section.

2. Illumination Bulb
To remove the illumination bulb, insert an ordinary screwdriver
into the slot (B) at the back of the bulb. Turn the bulb
counterclockwise and pull it free.

Page 3086 of 4264

1-76 HEATER AND AIR CONDITIONING
INSPECTION AND REPAIR



840R300005-X

Resistor
As for air-conditioning model, fixed on left (RHD) / right (LHD)
side of the evaporator unit.
As for heater only model, fixed on left (RHD) / right (LHD) side
of the duct placed between blower unit and heater unit.
Replace the resistor with a new on if the coil is found to be
open or if the resistance value deviates from the specified
range.




Terminal Resistance
3 – 2 1.99 

3 – 4 0.9 

3 – 1 0.17 



Blower motor
Check blower motor for smooth rotation.
Connect the battery positive terminal to the No.1 terminal of the
blower motor and negative to the No.2.
Be sure to check to see if the blower motor operates correctly.

Page 3087 of 4264

HEATER AND AIR CONDITIONING 1-77
D08R300070
Fan switch and Circuit board
Check for continuity between fan switch and A/C switch side
connector terminals.


B-13 B-57
Terminal
No.
SW.
position
1 2 3 4 5 6 2 3 10 11
OFF
1
2
3
(FAN SW.)
4
OFF CIRCUIT
BOARD
(A/C SW.)
ON


Electronic Thermostat
Check for continuity between electronic thermostat side
connector terminals.
(Cooler)



RTW410SH000201

(A/C)

Page 3088 of 4264

1-78 HEATER AND AIR CONDITIONING


RTW4A0SH000201

Pressure switch
Disconnect pressure switch connector and check for continuity
between pressure switch side connector terminal.


825r300045


Heater and thermo switch relay.
Check for continuity between the relay terminals.

1 - 5 
No continuity
(When battery voltage is applied between 2 - 4 )
1 - 5 
Continuity
825r300023

Check for continuity between the relay terminals.
1 - 2 
No continuity
(When battery voltage is applied between 3 - 4 )
1 - 2 
Continuity

Page 3089 of 4264

HEATER AND AIR CONDITIONING 1-79

TROUBLESHOOTING
FAN CONTROL KNOB (FAN SWITCH)
Current flows to the blower motor through the Heater & A/C relay (X-11) to activate the rotation of the blower motor
by turning “ON” the fan control knob (fan switch). Blower motor speed is controlled in stages by the resistor, by
operating the switch from “LOW” to “HIGH.”

D08R300046-X2

Page 3090 of 4264

1-80 HEATER AND AIR CONDITIONING

BLOWER MOTOR DOES NOT RUN


Replace
YES
 Is No.SBF-8 (30A) slow blow fuse OK?
Is heater & A/C relay (X-11) OK?
YES
 Is resistor OK?
YES
 Is fan control knob (Fan switch) OK?
YES
YES
 Check to see if battery voltage is present at
chassis side connector terminal No.C105-1 is there a
battery voltage?
 Turn the ignition switch "ON" (Engine is running)
 Fan control knob (Fan switch) "ON"
 Is blower motor OK?
YES
Poor ground or open circuit either between chassis
side connector terminal No.C105-2 and No.C104-3
or No.B13-1 and body ground No.C-109.
NO
Replace
NO
Replace
NO
NO
Replace control lever
assembly
Replace
NO
NO
Open circuit between
No.SBF-8 (30A) slow blow
fuse and No.C105-1.