dimensions KIA CARNIVAL 2007 Workshop Manual
Page 1328 of 1575
1.Vehicle condition
Moving
a. (IGN=OFF and Vehicle Speed > 5 km/h) or (IGN= ON and (Vehicle Speed > 5 km/h or PIN - not P/N))
Not moving a. (IGN=OFF and Vehicle Speed < 5 km/h) or (IGN= ON and (Vehicle Speed < 5 km/h and TRANS - P/N))
2. DOOR TRAVEL - ZONES
The door travel is divided into four zones starting at the full closed and latched position.
Dimensions are at the rear edge of the door and are approximate.
Zone 1 - Latching - 0 to 10 mm (primary and secondary latch positions).
Zone 2 - Near latching position including curved track portion - 10 to 300 mm.
Zone 3 - Straight track - 300 mm to hold open latch.
Zone 4 - Hold Open - door in hold open latch.
POWER SLIDING DOOR OPERATION
1.Vehicle condition
Stopping condition
a. When the ignition switch is in the OFF or ACC position, vehicle is stopped or moving below 5 km/h.
b. When the ignition switch is in the ON position, vehicle is stopped or moving below 5 km/h (the gearshift lever is
in N(Neutral) for manual transaxle, P(Park) for automatic transaxle).
Driving condition a. When the ignition switch is in the OFF or ACC position, vehicle is moving above 5 km/h.
b. When the ignition switch is in the ON position, vehicle is moving above 5 km/h or the gearshift lever is not in
N(Neutral) for manual transaxle, P(Park) for automatic transaxle.
Page 1370 of 1575
POWER OPERATION
The PTG system shall not open the Tailgate when the vehicle is moving.
The PTG system shall operate through the full range of Tailgate travel.
The PTG system shall learn the position of each travel extreme: full open and full closed.
1.Vehicle condition
Moving
a. (IGN=OFF and Vehicle Speed > 5 km/h) or (IGN= ON and (Vehicle Speed > 5 km/h or TRANS - not P/N))
Not moving a. (IGN=OFF and Vehicle Speed < 5 km/h) or (IGN= ON and (Vehicle Speed < 5 km/h and TRANS - P/N))
2. TAILGATE TRAVEL ZONES
The Tailgate travel is divided into four zones starting at the full closed and latched position. Dimensions are at the
bottom edge of the Tailgate and are approximate.
Zone 1 : Power Latching - from primary to secondary latch (0 to 10 mm depending on latch travel).
Zone 2 : Between Secondary and Crossover Point (Secondary to 20 degrees)
Zone 3 : Between Crossover Point and Power Off (20 degrees to 79 degrees)
Zone 4 : Power Off to Full Open - approximately 5° (15 counts from full open)