± BODY ELECTRICALPOWER WINDOW CONTROL SYSTEM
BE±127
2428 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
(d) Reverse the polarity and check that pulse is generated.
If operation is not as specified, replace the motor.
NOTICE:
If connecting the wire harness wrongly, the sensor might
be damaged so caution is necessary.
32. Front passenger's door:
INSPECT JAM PROTECTION PULSE SWITCH CIR-
CUIT
(See page DI±914)
33. Rear LH side door:
INSPECT JAM PROTECTION PULSE SWITCH
(a) Connect the positive (+) lead from the TOYOTA electrical
tester to terminal 3 and the negative (±) lead to terminal
5.
(b) Connect the positive (+) lead from the battery to terminal
2 and the negative (±) lead to terminal 1.
(c) Check that pulse is generated during the motor running.
(d) Reverse the polarity and check that pulse is generated.
If operation is not as specified, replace the motor.
NOTICE:
If connecting the wire harness wrongly, the sensor might
be damaged so caution is necessary.
34. Rear RH side door:
INSPECT JAM PROTECTION PULSE SWITCH
(a) Connect the positive (+) lead from the TOYOTA electrical
tester to terminal 3 and the negative (±) lead to terminal
5.
(b) Connect the positive (+) lead from the battery to terminal
1 and the negative (±) lead to terminal 2.
(c) Check that pulse is generated during the motor running.
(d) Reverse the polarity and check that pulse is generated.
If operation is not as specified, replace the motor.
NOTICE:
If connecting the wire harness wrongly, the sensor might
be damaged so caution is necessary.
Page 162 of 1111
BE±128
± BODY ELECTRICALPOWER WINDOW CONTROL SYSTEM
2429 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
35. CHECKING OF THE JAM PROTECTION FUNCTION
NOTICE:
Never, ever be caught any part of your body when check-
ing.
HINT:
In case of performing resetting of the limit switch, do checking
after repeating up and down of the glass with automatic opera-
tion.
(a) Confirmation of AUTO up operation:
Confirm that the window will be fully close with AUTO up
operation.
(b) Checking of the operation of the jam protection function:
(1) Move up the window with AUTO up operation and
check that the window will go down when it touches
the handle of the hammer stetted.
(2) Confirm that the window will then stop going down
about 200 mm.
HINT:
In case of removing the glass, glass guide, regulator and etc.
be sure to perform checking of the jam protection function.
If the jam protection is not function properly, adjust power win-
dow motor reset switch and pulse switch.
Page 163 of 1111
BE0HG±04
± BODY ELECTRICALPOWER WINDOW CONTROL SYSTEM
BE±129
2430 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
ADJUSTMENT
HOW TO RESET POWER WINDOW MOTOR (RESET SWITCH AND PULSE SWITCH)
If the jam protection is not functioned properly, perform the following procedure.
HINT:
It is necessary to reset the power window motor (in initial position for the limit switch) when separating the
window regulator from the power window motor or operating the window regulator with the door glass not
installed.
(a) Remove the power window motor. (See page BO±12, BO±18)
HINT:
Place the matchmarks on the power window motor and window regulator gear.
(b) Connect the power window motor and power window switch to wire harness of the vehicle.
(c) Turn the ignition switch ON and operate the power window switch to idle the power window motor in
UP side direction for more than 6 rotations or less than 10 rotates (4 seconds or more).
(d) Assemble the power window motor and regulator.
HINT:
Install the motor when the regulator arm is below the middle point.
Align the matchmarks on the power window motor and window regulator gear when install the power
window motor.
(e) Assemble the power window regulator and door glass.
HINT:
Never rotate the motor to the down direction until the completion of the window glass installation.
(f) Connect power window switch to wire harness and turn the ignition switch ON.
(g) Repeat UP and DOWN operation several times manually.
(h) Check if AUTO UP " AUTO DOWN operates in automatic operation.
HINT:
Take care that the jam protection function does not operate just after resetting.
Reset the regulator again when performing the reverse operating after closing the window fully by
AUTO UP operation.
(i) Check the power window function.