MITSUBISHI ENDEAVOR 2004 Service Repair Manual

Page 2191 of 3870

NO:
Repair or replace the connector. Refer to
HARNESS
CONNECTOR INSPECTION
. Check that the outside/inside air
selection damper control motor works normally.
Fig. 127: Locating Connector C
-16
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.

STEP 7. Check the wiring harness between outside/inside air selection
damper control motor connector C-106 (terminals 4 and 5) and A/C-ECU
C-16 (terminals 5 and 6).

Q: Is the wiring harness between outside/inside air selection damper
control motor connector C-106 (terminals 4 and 5) and A/C-ECU C-16
(terminals 5 and 6) in good condition?

2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor

Page 2192 of 3870

YES:
Go to Step 8.
NO:
Repair the wiring harness. Check that the outside/inside air selection
damper control motor works normally.

2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor

Page 2193 of 3870

Fig. 128: Locating Connectors C
-106 And C
-16
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.

2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor

Page 2194 of 3870

Disassembling STEP 8. Retest the system.

Q: Does a malfunction take place again?

YES:
Replace the A/C-ECU, and check that the outside/inside air
selection damper control motor works normally.
NO:
It can be assumed that this malfunction is intermittent. Refer to
HOW TO USE TROUBLESHOOTING/ INSPECTION SERVICE POINTS
.
INSPECTION PROCEDURE 4: WHEN THE A/C IS OPERATING, TEMPERATURE INSIDE THE PASSENGER
COMPARTMENT DOES NOT DECREASE (COOL AIR IS NOT EMITTED).
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor

Page 2195 of 3870

Fig. 129: View Of A/C Compressor Sensor Circuit

Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor

Page 2196 of 3870

Fig. 130: Identifying Connectors

Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.

TECHNICAL DESCRIPTION (COMMENT) If cool air is not distributed when the A/C switch is on
, the A/C com
pressor clutch

2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor

Page 2197 of 3870

relay system may be defective. TROUBLESHOOTING HINTS
Improper amount of refrigerant Malfunction of the air thermo sensor Malfunction of the ambient air temperature sensor Malfunction of the A/C pressure sensor Malfunction of the A/C compressor clutch relay Malfunction of the A/C refrigerant temperature switch Malfunction of the air conditioning compressor clutch Malfunction of the A/C-ECU Malfunction of the PCM Damaged harness wires or connectors
DIAGNOSIS REQUIRED SPECIAL TOOLS:

MB991223: Test Harness Set MB991958: Scan Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.) MB991827: MUT-III USB Cable MB991910: MUT-III Main Harness A (Vehicles with CAN
communication system)
STEP 1. Check the defogger and outside/inside air selection damper
control motor operation.

Q: Do the defogger and outside/inside air selection damper control motor
work normally?

YES:
Go to Step 2.
NO:
Refer to
INSPECTION PROCEDURE 10 MALFUNCTION OF
THE A/C
-ECU POWER SUPPLY SYSTEM
.

2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor

Page 2198 of 3870

STEP 2. Check the blower motor operation.

Q: Does the blower motor work normally?

YES:
Go to Step 3.
NO:
Refer to
INSPECTION PROCEDURE 5 BLOWER FAN AND
MOTOR DO NOT TURN
.
STEP 3. Check the A/C compressor.

Check the A/C compressor for compressor oil leaks.
Q: Is the check result satisfactory?

YES:
Go to Step 4.
NO:
Replace the A/C compressor or the expansion valve.
STEP 4. Using scan tool MB991958, read the diagnostic trouble code.

Check if an A/C-ECU DTC is set.
1. Connect scan tool MB991958 to the data link connec
tor.

2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor

Page 2199 of 3870

Fig. 131: Connecting Scan Tool MB991958 To Data Link Connector

Courtes
y of MITSUBISHI MOTOR SALES OF AMERICA
.

2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor

Page 2200 of 3870

2. Turn the ignition switch to the "ON" position
3. Check if the DTC is set.
4. Turn the ignition switch to the "LOCK" (OFF) position. Q: Is the check result satisfactory?

YES:
Go to Step 5.
NO:
Refer to
DIAGNOSTIC TROUBLE CODE CHART
.
STEP 5. Check A/C compressor clutch relay connector B-16X for loose,
corroded or damaged terminals, or terminals pushed back in the
connector.

Q: Is A/C compressor clutch relay connector B-16X in good condition?

YES:
Go to Step 6.
NO:
Repair or replace the connector. Refer to
HARNESS
CONNECTOR INSPECTION
. Check that the air conditioning works
normall
y.

2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor

Page:   < prev 1-10 ... 2151-2160 2161-2170 2171-2180 2181-2190 2191-2200 2201-2210 2211-2220 2221-2230 2231-2240 ... 3870 next >