NISSAN TEANA 2003 Service Manual
Page 3101 of 3502
ELECTRICAL UNITS LOCATION
PG-67
C
D
E
F
G
H
I
J
L
MA
B
PG
ELECTRICAL UNITS LOCATIONPFP:25230
Electrical Units Location BKS00251
ENGINE COMPARTMENT
CKIM0363E
Page 3102 of 3502
PG-68
ELECTRICAL UNITS LOCATION
PASSENGER COMPARTMENT
CKIM0672E
Page 3103 of 3502
ELECTRICAL UNITS LOCATION
PG-69
C
D
E
F
G
H
I
J
L
MA
B
PG
CKIM0673E
Page 3104 of 3502
PG-70
ELECTRICAL UNITS LOCATION
LUGGAGE COMPARTMENT
CKIM0674E
Page 3105 of 3502
HARNESS CONNECTOR
PG-71
C
D
E
F
G
H
I
J
L
MA
B
PG
HARNESS CONNECTOR PFP:00011
DescriptionBKS002FR
HARNESS CONNECTOR (TAB-LOCKING TYPE)
The tab-locking type connectors help prevent accidental looseness or disconnection.
The tab-locking type connectors are disconnected by pushing or lifting the locking tab(s). Refer to the fig-
ure below.
Refer to the next page for description of the slide-locking type connector.
CAUTION:
Never pull the harness or wires when disconnecting the connector.
[Example]
SEL769DA
Page 3106 of 3502
PG-72
HARNESS CONNECTOR
HARNESS CONNECTOR (SLIDE-LOCKING TYPE)
A new style slide-locking type connector is used on certain systems and components, especially those
related to OBD.
The slide-locking type connectors help prevent incomplete locking and accidental looseness or discon-
nection.
The slide-locking type connectors are disconnected by pushing or pulling the slider. Refer to the figure
below.
CAUTION:
Never pull the harness or wires when disconnecting the connector.
Be careful not to damage the connector support bracket when disconnecting the connector.
[Example]
SEL769V
Page 3107 of 3502
HARNESS CONNECTOR
PG-73
C
D
E
F
G
H
I
J
L
MA
B
PG
HARNESS CONNECTOR (LEVER LOCKING TYPE)
Lever locking type harness connectors are used on certain control units and control modules such as
ECM, ABS actuator and electric unit (control unit), etc.
Lever locking type harness connectors are also used on super multiple junction (SMJ) connectors.
Always confirm the lever is fully locked in place by moving the lever as far as it will go to ensure full con-
nection.
CAUTION:
Always confirm the lever is fully released (loosened) before attempting to disconnect or connect these
connectors to avoid damage to the connector housing or terminals.
LKIA0670E
1. Control unit with single lever
A. Fasten
B. Loosen
C. Lever2. Control unit with dual levers
A. Levers
B. Fasten
C. Loosen3. SMJ connector
A. Lever
B. Fasten
C. Loosen
Page 3108 of 3502
PG-74
ELECTRICAL UNITS
ELECTRICAL UNITS PFP:00011
Terminal Arrangement BKS00253
CKIM0675E
Page 3109 of 3502
ELECTRICAL UNITS
PG-75
C
D
E
F
G
H
I
J
L
MA
B
PG
CKIM0676E
Page 3110 of 3502
PG-76
SMJ (SUPER MULTIPLE JUNCTION)
SMJ (SUPER MULTIPLE JUNCTION)PFP:B4341
Terminal ArrangementBKS00254
CKIH0276E