Connector NISSAN TEANA 2003 Service Manual
Page 1697 of 3502
TROUBLE DIAGNOSIS
EC-415
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
ECM Harness Connector Terminal LayoutBBS004YD
ECM Terminals and Reference ValueBBS004YE
PREPARATION
1. ECM is located behind the glove box. For this inspection,
remove glove box.
2. Remove ECM harness connector.
3. When disconnecting ECM harness connector, loosen it with
levers as far as they will go as shown in the figure.
4. Connect a break-out box (SST) and Y-cable adapter (SST)
between the ECM and ECM harness connector.
Use extreme care not to touch 2 pins at one time.
Data is for comparison and may not be exact.
ECM INSPECTION TABLE
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECMs transistor. Use a ground other than ECM terminals, such as the ground.
MBIB0045E
PBIB2464E
PBIB2466E
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
1 B ECM ground[Engine is running]
Idle speedBody ground
Page 1704 of 3502
EC-422
[VQ]
TROUBLE DIAGNOSIS
70 W Refrigerant pressure sensor[Engine is running]Warm-up condition
Both A/C switch and blower fan switch: ON
(Compressor operates)1.0 - 4.0V
73 LGEngine coolant temperature
sensor[Engine is running]Approximately 0 - 4.8V
Output voltage varies with
engine coolant temperature.
74 LHeated oxygen sensor 2
(Bank 1)[Engine is running]
Revving engine from idle to 3,000 rpm
quickly after the following conditions are
met.
–Engine: After warming up
–Keeping the engine speed between 3,500
and 4,000 rpm for 1 minute and at idle for 1
minute under no load0 - Approximately 1.0V
78 BSensor ground
(Heated oxygen sensor)[Engine is running]
Warm-up condition
Idle speedApproximately 0V
79
80
81GR/R
GR
G/RIgnition signal No. 6
Ignition signal No. 4
Ignition signal No. 2[Engine is running]
Warm-up condition
Idle speed
NOTE:
The pulse cycle changes depending on rpm
at idle0 - 0.3V
[Engine is running]
Warm-up condition
Engine speed: 2,500 rpm0.1 - 0.6V
82 BSensor ground
(APP sensor 1)[Engine is running]
Warm-up condition
Idle speedApproximately 0V
83 GSensor ground
(APP sensor 2)[Engine is running]
Warm-up condition
Idle speedApproximately 0V
85 O Data link connector[Ignition switch: ON]
CONSULT-II: DisconnectedApproximately 5V - Battery volt-
age (11 - 14V)
86 Y CAN communication line[Ignition switch: ON]Approximately 1.1 - 2.3V
Output voltage varies with the
communication status
90 R/WSensor power supply
(APP sensor 1)[Ignition switch: ON]Approximately 5V
91 PSensor power supply
(APP sensor 2)[Ignition switch: ON]Approximately 5V
94 L CAN communication line[Ignition switch: ON]Approximately 2.6 - 3.2V
Output voltage varies with the
communication status. TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
SEC986C
SEC987C
Page 1714 of 3502
EC-432
[VQ]
TROUBLE DIAGNOSIS
DATA MONITOR (SPEC) MODE
Monitored Item
NOTE:
Any monitored item that does not match the vehicle being diagnosed is deleted from the display automatically.
ACTIVE TEST MODE
Test Item
Monitored item [Unit]ECM
INPUT
SIG-
NALSMAIN
SIG-
NALSDescription Remarks
ENG SPEED [rpm]××
Indicates the engine speed computed
from the signal of the crankshaft position
sensor (POS) and camshaft position
sensor (PHASE).
MAS A/F SE-B1 [V]××
The signal voltage of the mass air flow
sensor specification is displayed.When engine is running specification
range is indicated.
B/FUEL SCHDL
[msec]×
Base fuel schedule indicates the fuel
injection pulse width programmed into
ECM, prior to any learned on board cor-
rection.
When engine is running specification
range is indicated.
A/F ALPHA-B1 [%]
A/F ALPHA-B2 [%]×
The mean value of the air-fuel ratio feed-
back correction factor per cycle is indi-
cated.When engine is running specification
range is indicated.
This data also includes the data for the
air-fuel ratio learning control.
TEST ITEM CONDITION JUDGEMENT CHECK ITEM (REMEDY)
FUEL INJEC-
TION
Engine: Return to the original
trouble condition
Change the amount of fuel injec-
tion using CONSULT-II.If trouble symptom disappears, see
CHECK ITEM.
Harness and connectors
Fuel injector
Heated oxygen sensor 1
IGNITION TIM-
ING
Engine: Return to the original
trouble condition
Timing light: Set
Retard the ignition timing using
CONSULT-II.If trouble symptom disappears, see
CHECK ITEM.
Perform Idle Air Volume Learning.
POWER BAL-
ANCE
Engine: After warming up, idle
the engine.
A/C switch: OFF
Shift lever: P or N
Cut off each fuel injector signal
one at a time using CONSULT-II.Engine runs rough or dies.
Harness and connectors
Compression
Fuel injector
Power transistor
Spark plug
Ignition coil
COOLING FAN*
Ignition switch: ON
Turn the cooling fan “HI”, “MID”,
“LOW” and “OFF” using CON-
SULT-II.Cooling fan moves and stops.Harness and connectors
Cooling fan motor
IPDM E/R
ENG COOLANT
TEMP
Engine: Return to the original
trouble condition
Change the engine coolant tem-
perature using CONSULT-II.If trouble symptom disappears, see
CHECK ITEM.
Harness and connectors
Engine coolant temperature sen-
sor
Fuel injector
FUEL PUMP
RELAY
Ignition switch: ON (Engine
stopped)
Turn the fuel pump relay “ON”
and “OFF” using CONSULT-II
and listen to operating sound.Fuel pump relay makes the operat-
ing sound.Harness and connectors
Fuel pump relay
Page 1715 of 3502
TROUBLE DIAGNOSIS
EC-433
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
*: Leaving cooling fan OFF with CONSULT-II while engine is running may cause the engine to overheat.
REAL TIME DIAGNOSIS IN DATA MONITOR MODE (RECORDING VEHICLE DATA)
Description
CONSULT-II has two kinds of triggers and they can be selected by touching “SETTING” in “DATA MONITOR”
mode.
1. “AUTO TRIG” (Automatic trigger):
The malfunction will be identified on the CONSULT-II screen
in real time.
In other words, DTC/1st trip DTC and malfunction item will be
displayed if the malfunction is detected by ECM.
At the moment a malfunction is detected by ECM, “MONI-
TOR” in “DATA MONITOR” screen is changed to “Recording
Data ... xx%” as shown in the figure, and the data after the
malfunction detection is recorded. Then when the percentage
reached 100%, “REAL-TIME DIAG” screen is displayed. If
“STOP” is touched on the screen during “Recording Data ...
xx%”, “REAL-TIME DIAG” screen is also displayed.
The recording time after the malfunction detection and the
recording speed can be changed by “TRIGGER POINT” and
“Recording Speed”. Refer to CONSULT-II Operation Manual.
2. “MANU TRIG” (Manual trigger):
DTC/1st trip DTC and malfunction item will not be displayed
automatically on CONSULT-II screen even though a malfunc-
tion is detected by ECM.
DATA MONITOR can be performed continuously even though
a malfunction is detected.
Operation
1. “AUTO TRIG”
While trying to detect the DTC/1st trip DTC by performing the DTC Confirmation Procedure, be sure to
select to “DATA MONITOR (AUTO TRIG)” mode. You can confirm the malfunction at the moment it is
detected.
While narrowing down the possible causes, CONSULT-II should be set in “DATA MONITOR (AUTO
TRIG)” mode, especially in case the incident is intermittent.
VIAS SOL VALVE
Ignition switch: ON
Turn solenoid valve “ON” and
“OFF” using CONSULT-II and lis-
ten to operating sound.Solenoid valve makes the operating
sound.Harness and connectors
Solenoid valve
ENGINE
MOUNTING
Ignition switch: ON
Turn electronic controlled engine
mount “IDLE” and “TRVL” with
the CONSULT-II.Electronic controlled engine mount
makes the operating sound.Harness and connectors
Electronic controlled engine
mount
PURG VOL
CONT/V
Engine: After warming up, run
engine at 1,500 rpm.
Change the EVAP canister purge
volume control solenoid valve
opening percent using CON-
SULT-II.Engine speed changes according to
the opening percent.Harness and connectors
Solenoid valve
V/T ASSIGN
ANGLE
Engine: Return to the original
trouble condition
Change intake valve timing using
CONSULT-II.If trouble symptom disappears, see
CHECK ITEM.
Harness and connectors
Intake valve timing control sole-
noid valve TEST ITEM CONDITION JUDGEMENT CHECK ITEM (REMEDY)
PBIB1593E
SEF707X
Page 1716 of 3502
EC-434
[VQ]
TROUBLE DIAGNOSIS
When you are inspecting the circuit by gently shaking (or twisting) the suspicious connectors, compo-
nents and harness in the DTC Confirmation Procedure, the moment a malfunction is found the DTC/1st
trip DTC will be displayed. (Refer to “INCIDENT SIMULATION TESTS” in GI-24, "
How to Perform Effi-
cient Diagnosis for an Electrical Incident" .)
2. “MANU TRIG”
If the malfunction is displayed as soon as “DATA MONITOR” is selected, reset CONSULT-II to “MANU
TRIG”. By selecting “MANU TRIG” you can monitor and store the data. The data can be utilized for fur-
ther diagnosis, such as a comparison with the value for the normal operating condition.
CONSULT-II Reference Value in Data Monitor ModeBBS004YG
Remarks:
Specification data are reference values.
Specification data are output/input values which are detected or supplied by the ECM at the connector.
* Specification data may not be directly related to their components signals/values/operations.
i.e. Adjust ignition timing with a timing light before monitoring IGN TIMING, because the monitor may show the specification data in
spite of the ignition timing not being adjusted to the specification data. This IGN TIMING monitors the data calculated by the ECM
according to the signals input from the camshaft position sensor and other ignition timing related sensors.
PBIB0197E
MONITOR ITEM CONDITION SPECIFICATION
ENG SPEED
Run engine and compare CONSULT-II value with the tachometer indica-
tion.Almost the same speed as the
tachometer indication.
MAS A/F SE-B1 See EC-440, "
TROUBLE DIAGNOSIS - SPECIFICATION VALUE" .
B/FUEL SCHDL See EC-440, "
TROUBLE DIAGNOSIS - SPECIFICATION VALUE" .
A/F ALPHA-B1
A/F ALPHA-B2See EC-440, "
TROUBLE DIAGNOSIS - SPECIFICATION VALUE" .
COOLAN TEMP/S
Engine: After warming up More than 70°C (158°F)
HO2S1 (B1)
HO2S1 (B2)
Engine: After warming up Maintaining engine speed at 2,000 rpm 0 - 0.3V ←→ Approx. 0.6 - 1.0V
Page 1728 of 3502
EC-446
[VQ]
TROUBLE DIAGNOSIS - SPECIFICATION VALUE
15. DISCONNECT AND RECONNECT ECM HARNESS CONNECTOR
1. Stop the engine.
2. Disconnect ECM harness connector. Check pin terminal and connector for damage, and then reconnect it.
>> GO TO 16.
16. CHECK “A/F ALPHA-B1”, “A/F ALPHA-B2”
1. Start engine.
2. Select “A/F ALPHA-B1”, “A/F ALPHA-B2” in “DATA MONITOR (SPEC)” mode, and make sure that the
each indication is within the SP value.
OK or NG
OK >>INSPECTION END
NG >> Detect malfunctioning part according to EC-402, "
Symptom Matrix Chart" .
17. CHECK “B/FUEL SCHDL”
Select “B/FUEL SCHDL” in “DATA MONITOR (SPEC)” mode, and
make sure that the indication is within the SP value.
OK or NG
OK >>INSPECTION END
NG (More than the SP value)>>GO TO 18.
NG (Less than the SP value)>>GO TO 25.
18. DETECT MALFUNCTIONING PART
1. Check for the cause of large engine friction. Refer to the following.
–Engine oil level is too high
–Engine oil viscosity
–Belt tension of power steering, alternator, A/C compressor, etc. is excessive
–Noise from engine
–Noise from transmission, etc.
2. Check for the cause of insufficient combustion. Refer to the following.
–Valve clearance malfunction
–Intake valve timing control function malfunction
–Camshaft sprocket installation malfunction, etc.
>> Repair or replace malfunctioning part, and then GO TO 30.
19. CHECK INTAKE SYSTEM
Check for the cause of uneven air flow through mass air flow sensor. Refer to the following.
Crushed air ducts
Malfunctioning seal of air cleaner element
Uneven dirt of air cleaner element
Improper specification of intake air system
OK or NG
OK >> GO TO 21.
NG >> Repair or replace malfunctioning part, and then GO TO 20.
PBIB2332E
Page 1729 of 3502
TROUBLE DIAGNOSIS - SPECIFICATION VALUE
EC-447
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
20. CHECK “A/F ALPHA-B1”, “A/F ALPHA-B2”, AND “B/FUEL SCHDL”
Select “A/F ALPHA-B1”, “A/F ALPHA-B2”, and “B/FUEL SCHDL” in “DATA MONITOR (SPEC)” mode, and
make sure that the each indication is within the SP value.
OK or NG
OK >>INSPECTION END
NG (“B/FUEL SCHDL” is more, “A/F ALPHA-B1”, “A/F ALPHA-B2” are less than the SP value)>>GO TO 21.
21. DISCONNECT AND RECONNECT MASS AIR FLOW SENSOR HARNESS CONNECTOR
1. Stop the engine.
2. Disconnect mass air flow sensor harness connector. Check pin terminal and connector for damage and
then reconnect it again.
>> GO TO 22.
22. CHECK “A/F ALPHA-B1”, “A/F ALPHA-B2”
1. Start engine.
2. Select “A/F ALPHA-B1”, “A/F ALPHA-B2” in “DATA MONITOR (SPEC)” mode, and make sure that the
each indication is within the SP value.
OK or NG
OK >> 1. Detect malfunctioning part of mass air flow sensor circuit and repair it. Refer to EC-466, "DTC
P0102, P0103 MAF SENSOR" .
2. GO TO 29.
NG >> GO TO 23.
23. CHECK “MAS A/F SE-B1”
Select “MAS A/F SE-B1” in “DATA MONITOR (SPEC)” mode, and
make sure that the indication is within the SP value.
OK or NG
OK >> GO TO 24.
NG (More than the SP value)>>Replace mass air flow sensor, and
then GO TO 29.
24. REPLACE ECM
1. Replace ECM.
2. Perform initialization of NVIS(NATS) system and registration of all NATS ignition key IDs. Refer to BL-142,
"ECM Re-Communicating Function" .
3. Perform EC-389, "
Accelerator Pedal Released Position Learning" .
4. Perform EC-389, "
Throttle Valve Closed Position Learning" .
5. Perform EC-389, "
Idle Air Volume Learning" .
>> GO TO 29.
PBIB2370E
Page 1734 of 3502
EC-452
[VQ]
POWER SUPPLY AND GROUND CIRCUIT
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureBBS004YP
1. INSPECTION START
Start engine.
Is engine running?
Ye s o r N o
Yes >> GO TO 8.
No >> GO TO 2.
2. CHECK ECM POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF and then ON.
2. Check voltage between ECM terminal 109 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Fuse block (J/B) connector M1
10A fuse
Harness for open or short between ECM and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
1 B ECM ground[Engine is running]
Idle speedBody ground
109 R Ignition switch[Ignition switch: OFF]0V
[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
111 W / BECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition switch OFF0 - 1.0V
[Ignition switch: OFF]
More than a few seconds after turning ignition switch
OFFBATTERY VOLTAGE
(11 - 14V)
11 5
11 6B
BECM ground[Engine is running]
Idle speedBody ground
11 9
120R/G
R/GPower supply for
ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
Voltage: Battery voltage
MBIB0015E
Page 1735 of 3502
POWER SUPPLY AND GROUND CIRCUIT
EC-453
[VQ]
C
D
E
F
G
H
I
J
K
L
MA
EC
4. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten two ground screws on the body.
Refer to EC-457, "
Ground Inspection" .
OK or NG
OK >> GO TO 5.
NG >> Repair or replace ground connections.
5. CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-I
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminals 1, 115, 116 and ground.
Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F103, M52
Harness for open or short between ECM and ground
>> Repair open circuit or short to power in harness or connectors.
7. CHECK ECM POWER SUPPLY CIRCUIT-II
1. Reconnect ECM harness connector.
2. Turn ignition switch ON.
3. Check voltage between IPDM E/R terminal 17 and ground with
CONSULT-II or tester.
OK or NG
OK >> Go to EC-735, "IGNITION SIGNAL" .
NG >> GO TO 8.
PBIB2160E
Continuity should exist.
Voltage: Battery voltage
PBIB1610E
Page 1736 of 3502
EC-454
[VQ]
POWER SUPPLY AND GROUND CIRCUIT
8. CHECK ECM POWER SUPPLY CIRCUIT-III
1. Turn ignition switch ON and then OFF.
2. Check voltage between ECM terminals 119, 120 and ground
with CONSULT-II or tester.
OK or NG
OK >> GO TO 15.
NG (Battery voltage does not exist.)>>GO TO 9.
NG (Battery voltage exists for more than a few seconds.)>>GO TO
12.
9. CHECK ECM POWER SUPPLY CIRCUIT-IV
1. Turn ignition switch OFF.
2. Check voltage between ECM terminal 111 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 10.
NG >> GO TO 12.
10. CHECK ECM POWER SUPPLY CIRCUIT-V
1. Disconnect ECM harness connector.
2. Disconnect IPDM E/R harness connector E7.
3. Check harness continuity between ECM terminals 119, 120 and IPDM E/R terminal 18.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 18.
NG >> GO TO 11.
11 . DETECT MALFUNCTIONING PART
Check the following.
Harness or connectors E11, E253
Harness or connectors E102, M57
Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors. Voltage: After turning ignition switch OFF, battery
voltage will exist for a few seconds, then
drop approximately 0V.
MBIB0016E
Voltage: Battery voltage
PBIB1191E
Continuity should exist.